BAUR PGK 110 HB High-voltage test device

Code: BAUR PGK 110 HB


 

Datasheet PDF, 0.22 Mb

Description

There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.

 

Features:

  • Testing of medium- and high-voltage cables
  • DC voltage testing of up to 110 kV output voltage with positive or negative polarity
  • AC voltage testing - up to 80 kV for switchgear, busbars and insulating elements
  • Easy-to-maintain 2-piece design
 

More products BAUR

BAUR DTA IL OIL BREAKDOWN VOLTAGE TESTER

• Inline insulating oil testing in oil preparation systems
• Quality assurance during production processes
• Improved, easy oil sample handling
• Integration in existing production process control possible

 

BAUR PAULA PHASE DETECTOR

• Clear phase determination possible in cable lengths up to 40 km
• Highest level of safety when used on earthed and shorted cables in compliance with EN 50110-1 (DIN VDE 0105-100)
• Suitable for all switchgear constructions due to compact design of the signal injectors
• Ready for operation for up to 2 weeks (standby mode)

 

BAUR LIONA ONLINE PD SPOT TESTER

• Automatic PD detection during normal mains operation (without switching off the cable route)
• With DeCIFerĀ® technology: PD identification based on 500 million measurement results
• Precise online PD mapping with PD transponder

 

BAUR FRIDA VLF TESTING AND DIAGNOSTICS UNIT

• Precise and non-destructive determination of the cable condition
• Easy and quick test setup
• Automatic testing and diagnostic sequences
• Compact dimensions and lightweight

 

BAUR FRIDA TD VLF TESTING AND DIAGNOSTICS UNIT

• Cable testing and dissipation factor diagnostics in one device
• Easy and quick test setup
• Automatic testing and diagnostic sequences
• Compact dimensions and lightweight

 

BAUR IRG 2000 TIME DOMAIN REFLECTOMETER

• Easy and quick cable fault location
• Light, compact and manageable
• Main unit for the tried-and-tested pre-location method
• Ideal for integration in measurement systems

 

BAUR ATG 2 BURN DOWN TRANSFORMER

• Portable device for changing the fault resistance
• Useful for cables that are difficult to access
• Proven methods for complicated faults
• Independent current and voltage control on each burning level

 

BAUR PHG 70 TD PD / PHG 80 TD PD VLF TEST AND DIAGNOSTICS SYSTEM

• Compact, enclosed design in 19½ format
• Variable installation option with separate control and voltage unit
• Variable connection options to cable stations of different models

 

BAUR SHIRLA CABLE SHEATH TESTING AND FAULT LOCATION SYSTEM

• Cable and cable sheath testing up to 10 kVC
• Resistance measurement
• Cable and cable sheath fault pre-location with precision measuring bridge
• Adjustable cable sections that can be defined with length, conductor cross-section and material respectively and can be considered in the distance calculation

 

BAUR TG 600 AUDIO FREQUENCY TRANSMITTER

• High-performance audio frequency transmitter up to 600 VA
• Frequency of 2 or 10 kHz, quartz-stabilised (other frequencies on request)
• Potential-free output
• Impedance adjustment in 8 steps from 0.3 to 300 O