BAUR ATG 2 Burn down transformer

Code: BAUR ATG 2


 

Datasheet PDF, 0.25 Mb

Description

The ATG 2 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 2300 VA stray field transformer delivers a maximum voltage of 10 kV and is housed in a fully enclosed 19½ housing.

 

Features:

  • Portable device for changing the fault resistance
  • Useful for cables that are difficult to access
  • Proven methods for complicated faults
  • Independent current and voltage control on each burning level
 

More products BAUR

BAUR PGK 150 / 5 HB HIGH-VOLTAGE TEST DEVICE

• Testing of medium- and high-voltage cables
• DC voltage testing of up to 150 kV output voltage with positive or negative polarity
• AC voltage testing - up to 110 kV for switchgear, busbars and insulating elements
• Easy-to-maintain 2-piece design

 

BAUR PAULA PHASE DETECTOR

• Clear phase determination possible in cable lengths up to 40 km
• Highest level of safety when used on earthed and shorted cables in compliance with EN 50110-1 (DIN VDE 0105-100)
• Suitable for all switchgear constructions due to compact design of the signal injectors
• Ready for operation for up to 2 weeks (standby mode)

 

BAUR DTA IL OIL BREAKDOWN VOLTAGE TESTER

• Inline insulating oil testing in oil preparation systems
• Quality assurance during production processes
• Improved, easy oil sample handling
• Integration in existing production process control possible

 

BAUR KMF 1 SEARCH RECEIVER

• Battery mode
• Zero point compensation
• Accurate location of cable sheath faults
• Battery test

 

BAUR KSG 200 / KSG 200 T

• Cable identification on all types of de-energised cables
• Reliable verification of the cable identification by means
• of the highly precise three-factor-analysis ATP
• Safe cable identification on live low-voltage cables
• Connection technology according to CAT IV/600 V

 

BAUR ATG 6000 BURN DOWN TRANSFORMER

• Proven methodes for cable faults that are difficult to locate
• Useful for cables that are difficult to access
• Robust construction for reliable functions
• Independent current and voltage control on each burning level

 

BAUR DPA 75 C OIL BREAKDOWN VOLTAGE TESTER

• Compact and robust device for portable use onsite
• Test voltages from 0 to 75 kVrms
• Repeatable breakdown measurements in mineral, silicone and plant oils
• Reliable measurement results due to its short switch-off time (< 10 ½s)

 

BAUR LIONA ONLINE PD SPOT TESTER

• Automatic PD detection during normal mains operation (without switching off the cable route)
• With DeCIFerĀ® technology: PD identification based on 500 million measurement results
• Precise online PD mapping with PD transponder

 

BAUR DTL C OIL BREAKDOWN VOLTAGE TESTER

• Fully automatic dissipation factor measurement
• Pre-programmed standards
• Maximum accuracy

 

BAUR PGK 70 HB HIGH-VOLTAGE TEST DEVICE

• Testing of medium- and high-voltage cables
• DC voltage testing of up to 70 kV output voltage with positive or negative polarity
• AC voltage testing - up to 55 kV for switchgear, busbars and insulating elements
• Easy-to-maintain 2-piece design