BAUR IRG 2000 Time domain reflectometer

Code: BAUR IRG 2000


 

Datasheet PDF, 0.29 Mb

Description

The IRG 2000 impulse reflection measurement unit or time domain reflectometer is a handy, easy to carry device for single-phase cable fault pre-location. It is used in combination with a surge voltage generator on low-, medium- and high-voltage cables 0 - 65 km in length. It can also be used on live cables carrying voltage up to 400 V.

 

Features:

  • Easy and quick cable fault location
  • Light, compact and manageable
  • Main unit for the tried-and-tested pre-location method
  • Ideal for integration in measurement systems
 

More products BAUR

BAUR IRG 2000 TIME DOMAIN REFLECTOMETER

• Easy and quick cable fault location
• Light, compact and manageable
• Main unit for the tried-and-tested pre-location method
• Ideal for integration in measurement systems

 

BAUR DTL C OIL BREAKDOWN VOLTAGE TESTER

• Fully automatic dissipation factor measurement
• Pre-programmed standards
• Maximum accuracy

 

BAUR CL 20 CABLE LOCATOR

• Fast and exact location of position and laying depth of cables
• Intuitive operation ½ no special measurement knowledge required
• Lightweight and manageable

 

BAUR TRACY PARTIAL DISCHARGE INDUCTOR

• Portable, battery-operated signal coupling device
• Suitable for cables and cable accessories
• Inductive signal coupling
• Aviods costly, unnecessary replacements of PD-free cable accessories

 

BAUR KMF 1 SEARCH RECEIVER

• Battery mode
• Zero point compensation
• Accurate location of cable sheath faults
• Battery test

 

BAUR UL 30 AUDIO FREQUENCY SYSTEM

• Output energy up to 50 VA
• Automatic or manual impedance adjustment
• Charging unit and rechargeable battery integrated; battery or mains operation
• Continuous or cyclical output

 

BAUR PGK 25 DC HIGH-VOLTAGE TEST DEVICE

• Compact device for DC voltage testing with negative polarity
• Continuously adjustable output voltage
• Perfect for mobile use

 

BAUR PAULA PHASE DETECTOR

• Clear phase determination possible in cable lengths up to 40 km
• Highest level of safety when used on earthed and shorted cables in compliance with EN 50110-1 (DIN VDE 0105-100)
• Suitable for all switchgear constructions due to compact design of the signal injectors
• Ready for operation for up to 2 weeks (standby mode)

 

BAUR FRIDA TD VLF TESTING AND DIAGNOSTICS UNIT

• Cable testing and dissipation factor diagnostics in one device
• Easy and quick test setup
• Automatic testing and diagnostic sequences
• Compact dimensions and lightweight

 

BAUR FRIDA VLF TESTING AND DIAGNOSTICS UNIT

• Precise and non-destructive determination of the cable condition
• Easy and quick test setup
• Automatic testing and diagnostic sequences
• Compact dimensions and lightweight