pH-metru-Conductivimetru-Termometru de laborator Delta Ohm HD2256.2

Cod: Delta Ohm HD2256.2


 

Brosura produs PDF, 0.29 Mb

Descriere

Bench-top pHmeter-Conductivity meter-Thermometer with back-lighted display,

to measure pH, mV, ORP by pH, redox, separated reference electrodes, one input for a pH/temperature combined probe,

it measures conductivity, liquid resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes with

2 or 4 electrodes with direct input or with SICRAM module.

Datalogger for pH or mV, conductivity or resistivity or TDS and temperature.

RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.

Input for Pt100 or Pt1000 temperature probes provided with SICRAM module.

 

It is equipped with regulated power supply SWD10, instructions manual, software DELTALOG 11. Electrodes, conductivity probes, buffer solutions, TP87 and TP47... series temperature probes with SICRAM module and cables for PC connection have to be ordered separately.

 

Alte produse SENSECA

DETECTOR DE PLOAIE SI PRECIPITATII ATMOSFERICE DELTA OHM HD2013.2

• rain detector based on the capacity principle
• The instrument is equipped with three different outputs: a "Rain ON/OFF" output
• detects whether it is raining/ snowing (ON) or not (OFF), also used to control a relay coil or similar devices
• can be used either as a separate device, or connected to a data logger system

 

MINI-DATALOGGER TEMPERATURA SI UMIDITATE RELATIVA DELTA OHM HD206 HD226 HD207 HD227

• TEMPERATURE and RELATIVE HUMIDITY mini data logger with/no display
• Selectable storage interval 1-5-10-15-30 sec/min, 1 hour.
• Storage of 120,000 reading per channel,
• 8mm 3 ½ digit LCD display.
• IP54 protection degree.

 

PH-METRU PORTABIL CU TERMOMETRU DELTA OHM HD2305.0

• pHmeter-Thermometer which measures pH, mV and temperature.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

PIRHELIOMETRU CLASA INTAI MASURA IRADIERE DIRECTA FLUX SOLAR DELTA OHM LP PIRHE16

• The pyrheliometer LP PYRHE 16 First Class Pyrheliometer according to ISO 9060 classification
• is an instrument for direct measurement of solar irradiance (Watt/m2).
• The receiving surface must be positioned (via a solar tracker or else) perpendicularly to sun’s rays.
• By using suitable diaphragms only the direct light reaches the surface of the sensor.
• According to WMO (Seventh Edition 2008) and ISO 9069 regulations, the pyrheliometer has a field of view of 5°.

 

SONDA FOTOMETRICA EXTERIOR MASURA ILUMINANTA SOLARA DELTA OHM LP PHOT02

• Outdoor photometric probe for measuring ILLUMINANCE (0...150 Klux),
• CIE photopic filter,
• diffuser for cosine correction.
• mVdc output for klux.
• Complete with Calibration Report.
• On request 5 or 10m cables with connectors.

 

MANOMETRU-TERMOMETRU DIGITAL PORTABIL DELTA OHM HD2124.1 HD2124.2

• Manometer-Thermometer with two inputs for SICRAM module PP471 to connect probes TP704 and TP705 series.
• Temperature measurement with Pt100 probe complete with SICRAM module measuring range 200°C +650°C.
• Datalogger which stores the maximum, minimum, average value and can store up to 32,000 couples of samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD, PEAK and auto power off which can be disabled,
• IP 67 protection degree.

 

MANOMETRE-TERMOMETRE DIGITALE DELTA OHM HD2114 HD2134 HD2164

• portable instruments with a large LCD display
• They measure absolute, relative and differential pressure, as well as temperature
• Max, Min and Avg function calculates the maximum, minimum or average values
• relative measurement REL, the HOLD function, and the automatic turning off
• store up to 36,000 samples
• standard RS232C serial port and USB 2.0

 

RADIOMETRU NET RADIATIE SOLARA ULTRAVIOLETA-INFRAROSU DELTA OHM LP NET07

• LP NET 07 measures the net radiation across a surface, from near ultraviolet to
• far infrared.
• The Net radiation is defined as the difference between the radiation that reaches the upper surface and the irradiation on the lower surface of the net radiometer.
• The surface of the upper receiver measures the direct solar radiation plus the diffuse one and the radiation at longer wavelengths emitted from the sky (clouds), while the lower receiving area measures the solar radiation reflected from the ground (albedo) and the radiation length wavelengths emitted from the earth.
• The instrument is designed and constructed to be used outdoors in any weather
• conditions.

 

LUXMETRU FOTO-RADIOMETRU MASURA ILUMINANTA, PAR, IRADIANTA SOLARA DELTA OHM HD2102.1 HD2102.2

• Device for measuring illuminance, luminance, PAR, irradiance.
• Storage of maximum, minimum, average value and the integral Q(t),
• RS232 C output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

TESTER MULTIPARAMETRU MASURATORI ELECTROCHIMICE: PH, CONDUCTIVITATE, OXIGEN DIZOLVAT, REZISTIVITATE LICHIDE, SOLIDE DIZOLVATE, CONCENTRATIE DELTA OHM HD98569

• portable multi-parameter data logger for electrochemical measures: pH, conductivity, dissolved oxygen and temperature
• large back-lighted LCD display
• pH, mV, redox potential (ORP) with pH, redox or combined pH/temperature electrodes complete with SICRAM module
• conductivity, resistivity in liquids, total dissolved solids (TDS), and salinity with combined 4-ring and 2-ring conductivity and temperature probes with SICRAM module.
• Concentration of dissolved oxygen in liquids (in mg/l), saturation index (in %)