Radiometru net cu 4 componente masura radiatii solare Delta Ohm LP NET14

Cod: Delta Ohm LP NET14


 

Brosura produs PDF, 1 Mb

Descriere

LP NET 14 is a 4-component net-radiometer for the measurement of the net

radiation between 0.3µm and 45 µm.

The net-radiometer consists of two pyranometers (one for the measurement of

the global radiation Esw? and the other one for the measurement of the reflected

solar radiation Esw?) and a pair of pyrgeometers (one for the measurement of

the infrared radiation emitted by the sky EFIR? and the other one for the infrared

emitted by the ground surface EFIR?).

The LP NET 14 is equipped with a temperature sensor (NTC). The measurement

of the temperature is needed for the measurement with the two pyrgeometers,

in fact, the far infrared is derived by measuring the thermopile output and by the

knowledge of the instrument’s temperature.

The net radiometer is suitable for outdoor use in all weather conditions and

requires little maintenance.

 

Alte produse SENSECA

TESTER MULTIPARAMETRU MASURATORI ELECTROCHIMICE: PH, CONDUCTIVITATE, OXIGEN DIZOLVAT, REZISTIVITATE LICHIDE, SOLIDE DIZOLVATE, CONCENTRATIE DELTA OHM HD98569

• portable multi-parameter data logger for electrochemical measures: pH, conductivity, dissolved oxygen and temperature
• large back-lighted LCD display
• pH, mV, redox potential (ORP) with pH, redox or combined pH/temperature electrodes complete with SICRAM module
• conductivity, resistivity in liquids, total dissolved solids (TDS), and salinity with combined 4-ring and 2-ring conductivity and temperature probes with SICRAM module.
• Concentration of dissolved oxygen in liquids (in mg/l), saturation index (in %)

 

DATALOGGER FOTO-RADIOMETRU LUMINA SOLARA, TEMPERATURA DELTA OHM DO9721

• Datalogger Photo-radiometer Thermometer which performs photometric, radiometric, PAR, temperature measurements.
• Two inputs.
• Function as datalogger: 30,000 samples, REL, Record, Q (integration),
• RS232C serial output

 

TESTER LABORATOR PARAMETRI ELECTROCHIMIE: PH, CONDUCTIVITATE, OXIGEN DIZOLVAT, REZISTIVITATE LICHIDE, SOLIDE DIZOLVATE, CONCENTRATIE DELTA OHM HD22569.2

• bench top instrument for electrochemical measures: pH, conductivity, dissolved oxygen, and temperature.
• It is are fitted with a large backlighted LCD display.
• pH, mV, redox potential (ORP) with pH, redox electrodes or electrodes with separate reference;
• conductivity, resistivity in liquids,
• total dissolved solids (TDS) and salinity with combined 4-ring and 2-ring conductivity/
• temperature probes with direct input or SICRAM module;
• concentration of dissolved oxygen in liquids (in mg/l) and saturation index (in %),

 

RADIOMETRU NET CU 4 COMPONENTE MASURA RADIATII SOLARE DELTA OHM LP NET14

• LP NET 14 is a 4-component net-radiometer for the measurement of the net radiation between 0.3µm and 45 µm.
• consists of two pyranometers: one for the measurement of the global radiation Esw? and the other one for the measurement of the reflected solar radiation Esw?
• pair of pyrgeometers: one for the measurement of the infrared radiation emitted by the sky EFIR? and the other one for the infrared emitted by the ground surface EFIR?
• equipped with a temperature sensor (NTC).

 

LUXMETRU MASURA ILUMINANTA, PAR, IRADIANTA LUMINA SOLARA DELTA OHM HD2302.0 HD2302.0VP474

• Device for measuring illuminance, luminance, PAR, irradiance
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

DATALOGGER MULTIFUNCTIONAL 3 CANALE INREGISTRARE PARAMETRI CALITATE MEDIU AER DELTA OHM DO9847

• Multifunctional handheld board instrument and datalogger
• RH, temperature, pressure, airspeed, light, voltage, current
• 128x64 pixel (56x38 mm) graphic display and three independent inputs
• Functions: watch, hold, max., min., average, record, immediate or deferred start record logging, difference between the two inputs, relative measures
• Storage capacity: 32.000 readings per input.
• RS232C serial output: from 300 up to 115.200 baud rate.

 

PIRGEOMETRU METEO MASURA RADIATIE INFRAROSU DELTA OHM LP PIRG01

• The pyrgeometer LP PIRG 01 is used to measure the far infrared radiation (FIR).
• Its use is mainly in the meteorological field.
• Measures are referred to radiations with wavelength greater than 4.5 µm .
• The far infrared radiation derives from the measure of the thermopile output signal and from the knowledge of the instrument temperature. The temperature measure is performed by a 10kO NTC which is inside the body of the pyrgeometer.
• The pyrgeometer can be used also for the study of energy balance

 

PLUVIOMETRU MASURA CANTITATE SI DEBIT CADERI PRECIPITATII ATMOSFERICE PLOAIE DELTA OHM HD2013

• Rain gauge with tipping bucket,
• area 400cm2,
• for temperature range +4°C... +60°C.
• Standard resolution 0.2.
• On request at the time of placing the order resolution 0.1 or 0.5mm.
• Output contact normally closed.

 

DATALOGGER ANALIZOR MICRO-CLIMA WBGT DELTA OHM HD32.2 HD32.2A

• analysis of WBGT index (Wet Bulb Glob Temperature: wet bulb temperature and globe thermometer temperature) in presence or in absence of solar radiation
• Logging
• data transfer speed via the RS232 serial port
• The measurement unit of the temperature: °C, °F, °K
• Date and time of the instrument
• display of maximum, minimum, medium statistic parameters and their deletion

 

CONDUCTIVIMETRU-TERMOMETRU DE LABORATOR CU MASURA REZISTIVITATE LICHIDE, SOLIDE DIZOLVATE TDS DELTA OHM HD3406.2

• Bench-top Conductivity meter-Thermometer measures conductivity, liquid resistivity,
• total dissolved solids (TDS) and salinity by 2 or 4 electrodes,
• combined conductivity probes and temperature by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value, it can store up to 36,000 samples.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled.,
• protection degree IP 66