Reflectometru TDR localizare defecte cablu Megger TDR500/3

Cod: Megger TDR500/3 1002-227


 

Brosura produs PDF, 0.28 Mb

Descriere

• Simple operation.
• AUTO selection of gain and pulse width.
• Ultra fast pulse for near end fault identification.
• Trace HOLD feature.
• IP54 rating offers real life working.
• Designed for use on all metallic cable pairs.

 

 

The TDR500/3 is a hand held, compact Time Domain Reflectometer for locating faults on metallic cables. It has a minimum resolution of 0.1 m and a 5 km maximum range depending on velocity factor selected and cable type.

Four output impedances are available (25, 50, 75, and 100 O) and a velocity factor between 0.2 and 0.99 will meet any cable test requirements.

 

Accesorii standard

Time Domain Reflectometer 1002-227

Included accessories

Hard carry case 5410-420

Miniature clip test lead set 6231-652

User guide CD 2002-178

 

Optional accessories

Fused test lead set 1002-015

 

Alte produse MEGGER

BATTERY GROUND FAULT LOCATOR MEGGER - BGL

• Ground faults in ungrounded dc battery systems easily located
• Operates in high electrical noise environment
• Simplifies fault tracing by identifying fault characteristic (resistive and capacitive) magnitudes

 

MICRO-OHMETRU 200A MEGGER DLRO200

• Small and weighs less than 15kg
• Test currents from 10 A to 200 A d.c.
• 0.1 µO best resolution
• On board memory for up to 300 test results and notes
• RS232 port to download stored results or for real time output to a printer
• Supplied complete with 5m test leads and download software

 

CLESTE MASURA REZISTENTA IMPAMANTARE MEGGER DET14C DET24C

• Elliptical clamp shape improves access to earth cables and straps up to 50 mm
• Low maintenance flat jaw interface
• Measures ground resistance from 0.05 O to 1500 O
• Measures true RMS ground leakage current from 0.5 mA rms to 35 A rms
• CAT IV 600 V safety rating
• Backlit LCD display

 

TRUSA AVANSATA PRIZE DE PAMANT INALTA PRECIZIE SI REZOLUTIE MEGGER DET2/3

• Rezoluție înaltă de 1 mΩ, ideală pentru sisteme de împământare mari
• Moduri de testare versatile
• Precizie ridicată pentru testele de rețea ale electrodului de împământare/masă și rezistivitatea solului
• Baterie reîncărcabilă care poate dura toată ziua cu o reîncărcare rapidă (până la 10 ore)
• Instrument robust cu protecție IP65
• Selectare automată a frecvenței de testare, cu filtre și funcții de curent ridicat

 

KARL FISCHER MOISTURE IN OIL TEST SETS MEGGER ½ KF875 AND KF-LAB MKII

• Coulometric Karl Fischer titrimetry
• KF875 optimized for insulating oil with an SG of 0.875, completely portable
• KF-LAB MkII offers greater flexibility, versatility and sample data input than the KF875; also completely portable
• KF-LAB MkII analyzes materials with an SG between 0.6 & 1.4, plus insulating oils with an SG of 0.875

 

TESTER RAPORT TRANSFORMARE, DEPLASARE FAZA, REZISTENTA INFASURARE TRANSFORMATOARE MEGGER TTR100

• Tests turns ratio, phase displacement, excitation current, vector group, winding resistance and polarity
• Fully automatic; fast; easy-to-use; handheld; robust; lightweight
• Battery powered with power-saving and shutdown function
• Alphanumeric keyboard
• RS232 for data transfer and printing
• Stores 200 test results and 100 user-defined transformer test settings

 

TDR 2-CANALE LOCALIZARE DEFECTE CABLU MEGGER TDR2000/3 1003-036, TDR2000/3P 1003-037

• best resolution of 0.1m the TDR2000/2 has a 20km maximum range
• Comprehensive Dual Channel capability with dual aspect display.
• AUTO set up mode for instant use.
• Ultra fast pulse for near end fault identification.
• Xpert guidance to potential fault.
• IP54 rating offers real life working.
• Designed for use on all metallic paired cables.

 

FORK MULTIMETER MEGGER - DCM330

• 200.0 A a.c. open-jaw current measurement
• 0.1 V to 1000 V auto-ranging a.c. and d.c. voltage measurement
• 0.1 O to 20.00 MO resistance range
• Continuity buzzer

 

TRUSA TRIFAZATA DE VERIFICARE RELEE DE PROTECTIE MEGGER SVERKER900

• The toolbox for substation 3-phase testing
• Three currents and four voltages
• Stand-alone functionality
• Rugged and reliable for field use
• Generation of 900 V and 105 A in single phase mode
• Secondary and primary testing

 

TESTER INSTALATII ELECTRICE CONTINUITATE, IZOLATIE, CURENT SCURGERE SI ATINGERE MEGGER PAT120 PAT150

• Simple tick or cross, pass or fail indication plus measurement
• Tough, rubber armoured with built-in front cover, hardened, scratch-proof display window
• Includes 250 V insulation and leakage testing for safe IT testing and surge protected devices
• Testing portable and fixed electrical equipment
• 10 mA and 30 mA portable RCD lead testing (PAT150)
• Adjustable PASS test limits (PAT150)
• Substitute and mains powered leakage testing (PAT150)