Analizor de spectru 20 Hz..3.6 / 8.4 / 13.6 / 26.5 GHz Agilent N9020A MXA

Cod: Agilent N9020A MXA


 

Brosura produs PDF, 0.76 Mb

Descriere

  • 20 Hz to 3.6, 8.4, 13.6, or 26.5 GHz
  • 10 MHz (standard), 25 or 40 MHz (optional) analysis bandwidth
  • Basic EMI precompliance measurement capability available, including CISPR 16-1-1 bandwidths, detectors, amplitude correction factor, band preset, tune & listen at marker, and limit lines
  • internal preamplifier options up to 26.5 GHz
  • ±0.23 dB absolute amplitude accuracy
  • +20 dBm third order intercept (TOI)
  • -166 dBm displayed average noise level (DANL) with preamplifier
  • -78 dB W-CDMA ACLR dynamic range (with noise correction on)
  • Supports over 25 measurement applications, covering cellular communication, wireless connectivity, digital video and general purpose
  • Advanced analysis of more than 70 signal formats, software runs inside the MXA
  • MATLAB® data analysis software for general purpose data analysis, visualization, and measurement automation
  • LXI class C compliant, SCPI and IVI-COM
  • USB 2.0, 1000Base-T LAN, GPIB
  • Common X-Series user interface / Open Windows® XP operating system
 

Optiuni recomandate

  • Option 503    20 Hz to 3.6 GHz
  • Option 508    20 Hz to 8.4 GHz
  • Option 513    20 Hz to 13.6 GHz
  • Option 526    20 Hz to 26.5 GHz
 

Alte produse KEYSIGHT

SURSE REGLABILE DE LABORATOR 30-60W AGILENT E36XXA

• Linear power supply
• Single, dual or triple output
• 10-turn voltage and current control
• Low noise and excellent regulation

 

OSCILOSCOP DIGITAL 4 X 100 MHZ CU ANALIZOR LOGIC 16 CANALE AGILENT MSO7014B

• 100 MHz bandwidth
• 2 GSa/s sample rate
• 4 analog plus 16 digital channels
• 
• Standard 8 Mpts MegaZoom III deep memory

 

RLC-METRU DE PRECIZIE 75 KHZ..30 MHZ AGILENT 4285A

• 75 kHz to 30 MHz in 100 Hz steps
• 0.1% Accuracy
• Measurements include |Z|-theta, |Y|-theta, R-X, G-B, C-D, Q, ESR, G, Rp, L-D, deviation, and deviation %

 

MULTIMETRU DIGITAL DE PRECIZIE 5.5 DIGIT SI SURSA ALIMENTARE AGILENT U3606A

• 5.5 digit
• 0.025% DC Voltage accuracy
• 120,000 counts resolution
• Single-output dual range of 30V/1A or 8V/3A

 

MODUL MATRICE DUAL 4 X 8 AGILENT 34931A

• Dual 4x8, 8x8, or 4x16 configurations
• 64 2-wire cross-points
• Connections to the internal DMM
• Expandable via four 2-wire analog buses

 

GENERATOR FORME DE UNDA ARBITRARE 4.2 GSA/S AGILENT 81180A

• 10-MS/s to 4.2-GSa/s sample clock control
• 2 GHz IQ modulation bandwidth
• 12 bit vertical resolution
• 1 or 2 channel, coupled or uncoupled

 

OSCILOSCOP DIGITAL 4 X 500 MHZ CU ANALIZOR LOGIC 16 CANALE AGILENT MSOX3054A

• 500 MHz bandwidth
• 4 analog channels plus 16 digital channels
• 2 GSa/s per channel sample rate, 4 GSa/s half-channel interleaved mode


PUNTE MASURA CAPACITATI 120 HZ..1 MHZ AGILENT E4981A

• 120 Hz, 1 kHz, 1 MHz measurement frequency
• 0.07% Basic accuracy
• High-speed measurements to 2.3 ms @ 1 MHz

 

GENERATOR SEMNAL VECTORIAL 250 KHZ..20 GHZ/ 31.8 GHZ/ 44 GHZ AGILENT E8267D PSG

• 250 kHz to 20 GHz, 31.8 GHz or 44 GHz
• 0.001 Hz resolution
• +22 dBm @ 20 GHz and +18 dBm @ 40 GHz output power (typ)
• 160 MHz (extendable to 2 GHz) RF modulation bandwidth

 

MODUL PXI SWITCH MICROUNDE DC-26.5GHZ AGILENT M9157C

• Hybrid Single SP6T Switch Terminated
• Broadband from DC to 26.5 GHz
• Unmatched isolation 90 dB at 12 GHz
• Long life cycles - 2 million cycles guaranteed, 5 million cycles typical