GOODWILL INSTEK PPH-1503D & PPH-1506D

Cod: GOODWILL INSTEK PPH-1503D & PPH-1506D


 

Brosura produs PDF, 1.13 Mb
   

Descriere

GW Instek introduces new PPH-1503D programmable high precision dual-channel DC power supply. PPH-1503D½s CH1 provides dual operational ranges for voltage and current and its total power output is 45W. The dual operational ranges are 0 to 15V/0 to 3A or 0 to 9V/0 to 5A. CH2 provides 0 to 12V/0 to 1.5A with 18W power output.

 

PPH-1503D½s high precision measurement capability achieves the maximum resolution of 1mV/0.1uA and the smallest pulse current width of 33us that satisfy customers½ measurement application requirements of high resolution and pulse current. Fast load current variation will result in voltage sag for general power supplies that will have an impact on DUT½s internal circuit operation. PPH-1503D is equipped with the excellent transient recovery time, which can, in less than 40us, recover the output voltage to within 100mV of the previous voltage output when the current level changes from 10% to 100% of the full scale. Furthermore, conventional power supplies do not have sufficient response speed to promptly respond to set voltage value once the set voltage is changed. PPH-1503D has a rise time of 0.2ms and a fall time of 0.3ms, which are 100 times faster than that of conventional power supplies. Therefore, PPH-1503D can provide DUT with a stable output voltage even when DUT is operating under large transient current output. The internal high-speed sampling circuit design of PPH-1503D, with the sample rate of 64K, can conduct pulse current measurement without using a current probe and oscilloscope. The current read back accuracy is 0.2%+1uA (equals to 11uA) at 5mA range, and the read back resolution is 0.1uA that allow DUT to be measured with a high accuracy level. Unlike battery, general power supplies, which do not have the characteristics of fast transient recovery time, can not maintain a stable power supply for cellular phone, wireless device, and wearable device which produce large transient pulse current load for hundreds of ½s to dozens of ms when in use. PPH-1503D, different from general power supplies, has the characteristics of fast transient recovery time. While simulating battery to output pulse current, PPH-1503D can quickly compensate the voltage drop caused by pulse current. CH1 has the built-in battery simulation function, which can define output impedance settings so as to accurately simulate battery½s impedance characteristics during battery discharge. Fast transient recovery time and built-in battery simulation function together facilitate PPH-1503D to accurately simulate battery½s real behavior pattern so as to conduct product tests.

 

Features:

  • Dual Channel DC Power Output
  • Ch1: 45W (0~15V/0~3A or 0~9V/0~5A) / Ch2: 18W (0~12V/0~1.5A)
  • 3.5 inch TFT LCD Display
  • Built-in DVM Measurement Function
  • High Measurement Resolution (1mV/0.1½A for 5mA Range)
  • Current Sink Function (Maximum : 3.5A)
  • Pulse Current Measurement
  • Long Integration Current Measurement
  • Sequence Function (Sequential power output)
  • Built-in Battery Simulation Function
  • OVP, OCP, OTP & Temperature Display for Heat Sink
  • Support USB (Device& Host)/GPIB/LAN
  • 5 Groups of Save/Recall Setting
  • External RELAY Control
 

Alte produse INSTEK

GOODWILL INSTEK AFG-200/100 SERIES

• Frequency range: 1uHz~25MHz
• 1uHz frequency resolution
• Built-in 120 MSa/s, 10 bit resolution and arbitrary waveform editing function with 4k point memory
• Dual channel models support coupling, tracking, and phase functions

 

GOODWILL INSTEK PLR-SERIES

• Output Voltage Rating:20V / 36V / 60V
• Output Power:360W / 720W
• Low Ripple and Noise (0.5mVrms/ 10mArms)
• Fast transition recovery time(100us)
• Maximum 2 units in series connections or 3 units in parallel connections

 

GOODWILL INSTEK GDM-8255A

• GDM-8255A 199,999 Counts Display
• VFD Two Colors Display
• 0.012% DCV Accuracy
• True RMS (AC, AC+DC)

 

GOODWILL INSTEK GAG-810 & GAG-809

• Frequency from 10Hz ~ 1MHz
• 0.02% Low Sine Wave Distortion (GAG-810 Only)
• 6 Steps Output Attenuator
• EXT SYNC Function

 

GOODWILL INSTEK GUT-6000B

• Loop Test
• Auto-Search
• Self-Diagnosis
• Over-Load Protection

 

GOODWILL INSTEK GDM-400 & GDM-300

• 22000 Counts Auto/Manual Ranging (GDM-461)
• 4000 Counts Auto/Manual Ranging (GDM-397/398)
• 6000 Counts Auto/Manual Ranging (GDM-360)
• Capacitance, Frequency Measurement
• Continuity Beeper/Diode Test

 

OSCILOSCOAPE DIGITALE 2/4 CANALE 70/100/200/300MHZ INSTEK GDS-2000A

• GDS-2072A 70MHz ,2-channel ,Visual Persistence DSO
• GDS-2074A 70MHz ,4-channel ,Visual Persistence DSO
• GDS-2102A 100MHz ,2-channel ,Visual Persistence DSO
• GDS-2104A 100MHz ,4-channel ,Visual Persistence DSO
• GDS-2202A 200MHz ,2-channel ,Visual Persistence DSO
• GDS-2204A 200MHz ,4-channel ,Visual Persistence DSO
• GDS-2302A 300MHz ,2-channel ,Visual Persistence DSO
• GDS-2304A 300MHz ,4-channel ,Visual Persistence DSO

 

GOODWILL INSTEK GLC-9000

• Touch Panel with Color LCD Display
• 9 Different Measurement Network to Simulate the Resistance of Human Body
• 8 Different Types of Leakage current for Medical & General Electrical Equipment
• Various Leakage Current Measuring Mode:DC/AC/AC+DC/AC Peak

 

GOODWILL INSTEK GDM-8245

• Dual Display Indicate ACV and Hz,or DCV(ACV) and dBm
• Manual or Auto Ranging
• 0.03% DCV Accuracy
• ACV Measuring Frequency Up to 50kHz

 

GOODWILL INSTEK GCM-403 & GCM-407

• Auto Range, Expect Current Measurement
• Auto Power Off
• Max Hold
• True RMS Measurement (GCM-407)