Analizor calitatea puterii sisteme fotovoltaice mono si tri-fazice HT Italia Solar300N
PRODUS OBSOLET ( * SCOS DIN UZ )

Cod: HT Italia Solar300N


 

Brosura produs PDF, 1.63 Mb
 

Descriere

  • DC/AC TRMS (single-phase and three-phase) voltage measurement
  • DC/AC TRMS (single-phase and three-phase) current measurement
  • DC/AC (single-phase and three-phase) power measurement
  • AC (single-phase and three-phase) energy measurement
  • Measurement of power factor (cosphi) single-phase and three-phase
  • Measurement of solar irradiation [W/m2]
  • Measurement of environmental and module temperature by means of probe PT1000
  • Recording of voltage and current harmonics up to the 49th
  • Recording of voltage anomalies (dips, peaks)
  • Flicker analysis in compliance with standard EN50160
  • Recording of starting currents with a resolution of 10ms
  • Recording of voltage fast transients (spikes) with a resolution of 5us
  • Complete analysis of mains quality in compliance with standard EN50160
  • Numerical and graphical display of each quantity
  • Recalling results on the display
  • TFT colour display with touch screen
  • Power supply with rechargeable Li-ION battery
  • Memory extension by means of compact flash (CF card)
  • Data transfer to external USB memory (memory stick)
  • USB port for PC connection
  • Help on line at display
 

Accesorii standard

  • SOLAR-02: Remote unit to record irradiation and temperature
  • KIT800: Kit including 5 banana cables (black/blue/red/green/brown) + 5 alligator clips (black/blue/red/green/brown)
  • HT4005K: Transducer for AC currents 0÷200 A AC, 3pcs 
  • HT4004N: Transducer for DC currents 0÷10 - 0÷100 A
  • HT304: reference cell for irradiation measurement
  • PT300N: Double temperature probe (PT1000 + environmental)
  • A0055: Power supply 230V / 50-60Hz EU plug
  • YABAT0003HT1: Li-Ion 3,7V rechargeable battery
  • PT400: Touch screen pen
  • TOPVIEW2007: Software on CD-ROM and USB connection cable C2007
  • VA400: Hard Carrying case
  • User manual on CD-ROM
  • Quick guide
  • Calibration certificate ISO9000
 

Optiuni recomandate

  • MPP300: Multi-string three-phase adaptor
  • HT4004P: Unbatterried transducer for DC current 0-10, 0-100A, max diameter 30mm (**)
  • HT96U: Transducer for AC currents (including leakage current) 0÷1 - 0÷100 - 0÷1000A
  • HT97U: Transducer for AC currents 0÷10 - 0÷100 - 0÷1000 A AC
  • HT98U: Transducer for AC/DC currents 0÷1000 A AC/DC
  • HP30C2: Transducer for AC currents 0÷200 - 0÷2000 A AC
  • HTFLEX33D: Flexible transducer for 3000A AC current, diameter 174mm (*)
  • HTFLEX35: Flexible transducer for 3000A AC currents diameter 274mm (*)
  • HT903: Transducer 3x1-5A/1V for connection to CTs with accessories
  • SP-0400: Free hands kit
  • 606-IECN: Connector with magnetic clip
  • (*) only for using the instrument as power quality analyser
  • (**) to be used with MPP300 only
 

Alte produse HT ITALIA

MULTIMETRU DIGITAL PORTABIL MULTIFUNCTIONAL PROFESIONAL HT ITALIA M74

• ContiDC Voltage
• AC TRMS Voltage
• nuity test of protective conductors with 200mA
• Insulation Resistance with 250, 500VDC
• Trip-out time of RCDs type AC Standard
• Test current selectable; 30mA, 30x5mA, 100mA, 300mA
• Global Earth Resistance without RCD tripping
• Global Earth Resistance with 0.1Ohm resolution

 

INREGISTRATOR CURENTI RETEA ELECTRICA MONO/ TRI-FAZICA HT ITALIA XL421/ XL422

• TRMS AC current measure up to 2500A
• Recording with sampling programmable period
• Manual activation of recording
• RS-232 interface
• Programming with DATALINK software

 

TESTER DIGITAL MASURARE PRIZE DE PAMANT SI REZISTENTA BUCLA IMPAMANTARE RCD HT ITALIA SPEED 418

• Tripping time on RCD type A, AC General and Selective with currents 10, 30,100, 300, 500mA
• Tripping time on RCD type AC General with currents 30, 30x5, 100, 300mA
• Tripping current on RCD type A, AC General and Selective Global earth resistance without RCD tripping
• Line/Loop impedance, also with high-resolution (0.1m )( with optional accessory IMP57)
• Optical/USB interface for connection to PC

 

TRUSA MASURAREA TENSIUNII DE PAS SI ATINGERE CONTACT HT2055

• TRMS
• Interval de măsurare 200Ω
• Rezistență la împământare prin metoda cu 2 și 3 fire
• Rezistență la împământare prin metoda cu 4 fire
• Compensarea tensiunilor perturbatoare
• Compensarea cablurilor de testare
• Măsurarea tensiunii de pas/contact

 

HT I-V500W ANALIZOR SISTEME FOTOVOLTAICE CU TRASARE CURBA I-V 1500V 15A

• Trasator de curbă I-V pentru întreţinerea şi depanarea sistemelor fotovoltaice.
• Măsurarea curbei I-V a unuia sau mai multor module sau a unui şir întreg până la 1500V/10A
• Măsurarea tensiunii în circuit deschis şi a curentului de scurtcircuit Voc/Isc
• Bază de date cu 30.000 de module fotovoltaice selectabile

 

INREGISTRATOR TENSIUNE AC RETELE ELECTRICE MONO/ TRI-FAZICE HT ITALIA XL423/ XL424

• TRMS AC Voltage measure up to 600V
• Recording with sampling programmable period
• Manual activation of recording
• RS-232 interface
• Programming with DATALINK software

 

MULTIMETRU CALIBRATOR DIGITAL PORTABIL DE PROCES HT ITALIA HT8000

• Generation of output voltage signal with amplitude up to 10VDC
• Voltage measurement up to 10VDC
• Generation of output current signal with amplitude up to 24mADC
• Current measurement up to 24mAVDC
• Current measurement in percentage format (4-20mA)
• Loop current measurement of external transducers

 

THT600 CAMERA INFRAROSU 384X288PXL

• Rezoluție IR 384x288 pxl
• Interval de temperatură -20° ÷ 650°C
• Frecvență imagine 50Hz
• Sensibilitate termică / NETD <0.05°C @ 30°C / 50mK
• Câmp vizual (FOV) 17° x 12.7°

 

MEGOHMMTERU DIGITAL PROGRAMABIL PROFESIONAL 10TOHM 5KV HT ITALIA HT7051

• Insulation resistance measurement with test voltage up to 5kVDC
• Measurement range up to 10Tohm
• Polarization Index (P.I.) measurement
• Dielectric Absorption Ratio (D.A.R) measurement
• RS-232 interface for PC connection
• Rechargeable internal battery

 

MULTIMETRU MASURARE REZISTENTA PRIZELOR DE PAMANT HT ITALIA M71

• 3-wire Earth Resistance
• 2-wire Earth Resistance
• Measurement range up to 50kOhm
• Calibration of test cables
• Automatic regulation of noise voltage disturbances