Calibrator temperatura si termorezistente Fluke 712

Cod: Fluke 712


 

Brosura produs PDF, 0.11 Mb

Descriere

  • -200 to 800ºC Range Measure / simulate RTD (Pt 100)
  • 0 to 3200 O Range Measure / simulate resistance
  • 0.1 O, 0.1 ºC Resolution
  • 0.025% Accuracy
  • Measure temperature from RTD output
  • Simulate RTD output
  • Operates with seven types of RTDs
  • Measure additional RTDs using Ohms measurement function
  • Simulate additional RTDs using Ohms source function
  • ºF or ºC selectable
  • Four shrouded banana jacks
  • Compatible with Rosemount® pulsed RTD transmitters (pulses > 10ms)
  • Holster features test lead storage
  • Compatible with toolpack magnetic hanging system
 

Accesorii standard

  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • single 9V alkaline battery
  • Test Leads and Alligator Clips
  • NIST-traceable calibration report and data
 

Alte produse FLUKE

CLESTE AMPERMETRIC CURENT TRUE-RMS 400A FLUKE 324

• 400 A ac current measurement
• 600 V ac and dc voltage measurement
• True-rms ac voltage and current for accurate measurements on non-linear signals
• Resistance measurement up to 40 k? with continuity detection
• Temperature and capacitance measurement

 

MULTIMETRU PORTABIL IZOLAT IP67 4.5 DIGIT FLUKE 28 II

• 4.5 digit
• 20,000 count resolution for precise measurements
• 0.05% basic accuracy
• New - IP 67 waterproof & dustproof protection, completely sealed for use in harsh environments
• Peak min-max
• True-rms ac voltage and current for accurate measurements on non linear signals
• Built in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument

 

DETECTOR PREZENTA TENSIUNE FLUKE LVD1 VOLT LIGHT

• Detects voltages from 40 V AC to 300 V AC
• Non-contact AC voltage detector and LED flashlight
• exclusive dual-sensitivity

 

FLUKE 190-062 190-062/S OSCILOSCOP PORTABIL DIGITAL 2X60 MHZ

• 2-canale izolate 60MHz
• Clasa de protectie CAT III 1000 V, CAT IV 600 V
• Multimetru digital dedicat cu 5000 de numărări la modele cu două canale
• Măsurători automate avansate, energie (Vpwm, VA, W, PF) ™ timp (mAs, V/s, w/s)
• Clasa de protectie IP-51 pentru praf şi lichide pentru a rezista in medii dificile
• Porturi USB izolate

 

TESTER PORTABIL TEMPERATURA SI UMIDITATE FLUKE 971

• Temperature range from -20 °C to 60 °C (-4°F to 140 °F)
• Relative humidity from 5 % to 95 %
• Min/Max/Avg Data hold
• Low battery indicator

 

LOCATOR DE TRASEU CABLURI ACOPERITE, INGROPATE, PRIN PERETI FLUKE 2042

• pentru detectarea cablurilor în pereti si sub pamânt
• pentru localizarea sigurantelor/întrerupatoarelor de pe circuitele finale
• pentru localizarea întreruperilor si a scurtcircuitelor din cabluri si din instalatiile de încalzire prin pardoseala
• detectarea tevilor metalice pentru apa sau încalzire

 

CLESTE AMPERMETRIC DE CURENT TRUE-RMS AC/DC FLUKE 375

• iFlex fexible current probe compatible
• 600 A AC and DC current measurement with fxed jaw
• 2500 A AC current measurement with iFlex (sold separately)
• 600 V AC and DC voltage measurement
• True-rms AC voltage and current
• Frequency measurement to 500 Hz
• 60 k O resistance measurement
• 500 mV dc measurement range
• 1000 µF capacitance measurement

 

TESTER TENSIUNE SI CONTINUITATE FLUKE T120

• LED Bargraph
• Display: Fluke T120: 3½ digit LCD
• Voltage test
• Optical and acoustical continuity test

 

APARAT DE MASURA PRIZE DE PAMANT FLUKE 1625-2 GEO

• 3- and 4-pole Fall-of-Potential, earth resistance loop testing
• 4-pole Soil Resistivity testing
• Selective earth ground rod testing using 1 clamp
• Stakeless earth ground rod testing using 2 clamps
• IP56 rated for outdoor use
• USB data storage and transfer
• Automatic Frequency Control (AFC)
• R* measurement - calculates earth ground impedance at 55 Hz

 

TESTER INSTALATII ELECTRICE 50V-1000V FLUKE 1654B

• Test voltage: 50V, 100V, 250V, 500V, 1000V
• Two measurements at once and a dual display
• PEFC/PSC and loop impedance
• Fast voltage measurement between L-N, L-PE and N-PE
• PASS/FAIL indication for RCD test results
• Earth resistance