For the temperature calibration professional that wants a highly accurate, easy-to-use, single function RTD temperature calibrator the Fluke 712B is the ideal test tool.
Features at a Glance
|
General Specifications | |
|
Maximum voltage applied between any terminal and earth ground or between any two terminals |
30 V |
|
Operating temperature |
-10 °C to 50 °C |
|
Storage temperature |
-30 °C to 60 °C |
|
Operating altitude |
2,000 meters |
|
Storage altitude |
12,000 meters |
|
Relative humidity (% RH operating without condensation) |
Non condensing |
|
90% (10 °C to 30 °C) | |
|
75% (30 °C to 40 °C) | |
|
45% (40 °C to 50 °C) | |
|
(Without condensation) | |
|
Vibration requirements |
MIL-T-28800E, Class 2 |
|
Drop text requirements |
1 meter |
|
IP Rating |
IEC 60529: IP52 |
|
Electromagnetic environment |
IEC 61326-1, Portable |
|
Safety |
IEC 61010-1, Max 30 V to earth, Pollution Degree 2 |
|
Power supply |
4 AA NEDA 1.5A IEC LR6 batteries |
|
Size (H x W x L) |
52.5 mm x 84 mm x 188.5 mm |
|
Weight |
515 g |
Accesorii standard
Included equipment
Optiuni recomandate
|
Model Name |
Description |
|
Fluke 712B |
RTD Calibrator |
|
5627A-12-X |
Secondary PRT, 305 mm x 6.35 mm (12 x 1/4 in), -200 °C to 420 °C (17025 accredited calibration included. Traceable to NIST standards.) X = termination. Specify "A" (INFO-CON for 914X), "B" (bare wire), "D" (5-pin DIN for Tweener Thermometers), "G" (gold pins), "I" (INFO-CON for 1521 or 1522), "J" (banana plugs), "L" (mini spade lugs), "M" (mini banana plugs), "P" (INFO-CON for 1523 or 1524), or "S" (spade lugs). |
|
5627A-6-X |
Secondary PRT, 152 mm x 4.7 mm (6 x 3/16 in), -200 °C to 300 °C (17025 accredited calibration included. Traceable to NIST standards.) X = termination. Specify "A" (INFO-CON for 914X), "B" (bare wire), "D" (5-pin DIN for Tweener Thermometers), "G" (gold pins), "I" (INFO-CON for 1521 or 1522), "J" (banana plugs), "L" (mini spade lugs), "M" (mini banana plugs), "P" (INFO-CON for 1523 or 1524), or "S" (spade lugs). |
|
5627A-9-X |
Secondary PRT, 229 mm x 4.7 mm (9 x 3/16 in), -200 °C to 300 °C (17025 accredited calibration included. Traceable to NIST standards.) X = termination. Specify "A" (INFO-CON for 914X), "B" (bare wire), "D" (5-pin DIN for Tweener Thermometers), "G" (gold pins), "I" (INFO-CON for 1521 or 1522), "J" (banana plugs), "L" (mini spade lugs), "M" (mini banana plugs), "P" (INFO-CON for 1523 or 1524), or "S" (spade lugs). |
Alte produse FLUKE
|
FLUKE TI200 CAMERA INFRAROSU TERMOVIZIUNE 200X150
• Rezolutie detector : 200 X 150 pixeli |
|
TERMOMETRU INFRAROSU CU TERMOCUPLU DE CONTACT FLUKE 566/ FLUKE 568
• Measure -40 °C to 800 °C /-40 °F to 1472 °F (568) or -40 °C to 650 °C/-40 °F to 1202 °F (566) |
|
FLUKE TIS50 CAMERA DE TERMOVIZIUNE 220X165
• Fluke TiS10 80x60 pixels |
|
TETER PORTABIL MONOXID DE CARBON CO FLUKE CO-220
• Rugged case and electronics. |
|
CLESTE POWERMETRIC CU ANALIZOR PUTERE FLUKE 345
• 2000A AC/DC current |
|
TELEMETRU LASER PORTABIL 100M FLUKE 424D
• The ultimate Fluke laser distance meter |
|
TESTER TENSIUNE SI CONTINUITATE FLUKE T140
• Resistance measurement |
|
CALIBRATOR PORTABIL DE BUCLA FLUKE 707
• 0 to 28 V DC Voltage measure |
|
CLESTE AMPERMETRIC WIRELESS FLUKE CNX A3000
• Masuratori de curent c.a. true-RMS la 400 A |
|
RLC-METRU 50 HZ..1 MHZ FLUKE 6306
• 50, 60, 100, 120 Hz 200 Hz to 100 kHz (100 Hz steps) |