Calibrator de presiune Fluke 718Ex

Cod: Fluke 718


 

Brosura produs PDF, 0.54 Mb

Descriere

  • ATEX II  1G Ex ia IIC T4 Compliant
  • Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve
  • 30, 100, and 300 psi ranges (2, 7, and 20 bar)
  • Pressure measurement to 0.05% of full span, using an internal pressure sensor
  • Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules
  • Wide range of selectable measurement units for pressure
  • Current measurement with 0.02% accuracy and 0.001 mA resolution
  • Pressure switch test function
  • Min-Max Hold functions
  • Compact size and weight
  • Simple, push-button user interface
  • Rugged and reliable, ideal for field use
 

Accesorii standard

  • Protective Red Holster
  • TL75 Test Leads
  • AC72 Test Clips
  • CD Users Manuals
  • Fluke 718Ex CCD content control drawing
  • NIST- traceable calibration report and data
 

Optiuni recomandate

Fluke 718EX 30

Pressure Calibrator 30 PSI, EX - I.S.

Fluke 718EX 100G

Pressure Calibrator 100 PSI, EX - I.S

Fluke 718EX 300G

Pressure Calibrator 300 PSI, EX - I.S

 

Alte produse FLUKE

CALIBRATOR TEMPERATURA SI TERMOREZISTENTE FLUKE 712

• -200 to 800ºC Range Measure / simulate RTD (Pt 100)
• 0 to 3200 O Range Measure / simulate resistance
• 0.1 O, 0.1 ºC Resolution

 

TESTER MULTIFUNCTIONAL TEMPERATURA, UMIDITATE, VITEZA AER, CO, CO2 FLUKE 975

• Temperature -20 °C to 50 °C (-5 °F to 122 °F)
• Velocity 0.25 m/sec to 15 m/sec
• Relative Humidity 10 % to 90 % RH, non-condensing
• CO2 0 to 5000 ppm
• CO 0 to 500 ppm

 

ANALIZOR DE PUTERE DE PRECIZIE FLUKE NORMA 5000

• 3, 4 or 6 power phases
• Bandwidth from dc to 3 MHz / 10 MHz
• FFT analysis, vector diagram, and Digital Oscilloscope
• Voltage, current and power harmonics measured up to the 40th harmonic

 

CLESTE AMPERMETRIC DE CURENT TRUE-RMS AC/DC 200A FLUKE 365

• 200 A AC and DC current measurement with detachable jaw
• 600 V AC and DC voltage measurement
• True-rms AC voltage and current
• 6000 O resistance measurement

 

MEGOHMETRU DIGITAL MULTIMETRU IZOLATIE 50/ 1000V FLUKE 1507

• Insulation test range: 0.01 MO to 10 GO
• Insulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V

 

MULTIMETRU DIGITAL PORTABIL IZOLAT ATEX 4.5 DIGIT FLUKE 87V EX

• 4.5 digit
• 6000 count resolution for precise measurements
• 0.05% basic accuracy
• True-rms ac voltage and current for accurate measurements on non linear signals
• Selectable filter for accurate voltage and frequency measurements on motor drives
• Built in thermometer lets you carry one less tool (TC probe included)
• ATEX safety rating Ex II 2 G Eex ia IIC T4

 

LOCATOR DE TRASEU CABLURI ACOPERITE, INGROPATE, PRIN PERETI FLUKE 2042

• pentru detectarea cablurilor în pereti si sub pamânt
• pentru localizarea sigurantelor/întrerupatoarelor de pe circuitele finale
• pentru localizarea întreruperilor si a scurtcircuitelor din cabluri si din instalatiile de încalzire prin pardoseala
• detectarea tevilor metalice pentru apa sau încalzire

 

CALIBRATOR MULTIFUNCTIONAL DE PROCES FLUKE 726

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 20 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 4000 O Resistance measure / source / simulate
• 1 to 15 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure

 

TERMOMETRU INFRAROSU FARA CONTACT FLUKE 62 MAX

• Dust and water-resistant: IP54 rated for dust and water resistance.
• Rugged: 3-meter (9.8-foot) drop tested.
• Ergonomically designed: Completely redesigned for a more natural hand fit.
• Large, backlit display: Large screen makes data easier to read, even in dark areas.
• Min/Max/Avg/Dif: Displays the minimum, maximum or average temperature, or the difference between two measurements.
• Alarm: Hi and Lo alarms for rapid display of measurements outside the limits

 

MULTIMETRU DIGITAL PORTABIL HVAC 3.5 DIGIT FLUKE 116

• 3.5 digit
• 6000 count
• 0.5% accuracy
• Built-in thermometer for HVAC applications
• Microamps to test flame sensors