Sonda de injectie curent 10 kHz..400 MHz ETS-Lindgren 95236-1/ 95242-1

Cod: ETS-Lindgren 95236-1/ 95242-1


 

Brosura produs PDF, 0.41 Mb

Descriere

Description 95236-1 Current Probe

The probe's operating frequency range is 10 kHz to 100 MHz. This probe is most efficient from about 15 kHz to 4 MHz. The 95236-1 probe cover the low frequency portion of RTCA/DO-160C RF conducted susceptibility requirements and MIL-STD-461D I MIL-STD-462D CS114 (10 kHz · Z MHz).

The Model 95236-1 probe has a 1.6" window, making it suitable for injecting current into most power or signal cables. (AWG 4/0 cable, good for several hundred Amps, is 12.7 mm (0.5 in) diameter, exclusive of insulation.) 100 Watts of cw RF power may be driven into the probe in the injection mode.

Electrical Specifications 95236-1 Current Probe

Frequency Minimum

10 kHz

Frequency Maximum

100 MHz

Maximum Power

100 W

 

 

 

Description 95242-1 Injection Probes

It enables testing to be performed which previously required the use of two separate injection probes, the ERA type 36A and 37A This is our most efficient injection device from 4 MHz to almost 600 MHz The 95242-1 probe covers the high frequency portion of RTCA/DO-160C RF conducted susceptibility requirements and MIL-STD-461D I MIL-STD-462D CS114 (5 MHz - 400 MHz). This injection probe is also suitable for injecting the required current waveforms of MIL-STD-461D limits CS115 and CS116 (for CS116, one of our lower frequency probes is required as well). Testing to British Defense Standard DEF STA 59-41, Part 3 is also supported by this model. When necessary, our 95235-1 injection probe has larger 2.625" window diameter, but is less efficient than the 95242-1. When calibrating the Calibration Jig coupled current vs. forward power into the injection probe, the combination of 95242-1 probe and 95241-1 Jig has an excellent low VSWR.

The Model 95242-1 probe has a 1.6" window, making it suitable for injecting current into most power or signal cables. (AWG 4/0 cable, good for several hundred Amps, is 12.7 mm (0.5 in) diameter exclusive of insulation.) 100 Watts of cw RF power may be driven into the probe in the injection mode.

Electrical Specifications 95242-1 Injection Probes

Frequency Minimum

2 MHz

Frequency Maximum

400 MHz

Maximum Power

100 W

 

 

Alte produse ETS-LINDGREN

FILTRU PUTERE APLICATII TEMPEST/ EMP DE MARE PERFORMANTA CURENTI 16..200A ETS-LINDGREN N600X

• Suitable for 400Hz supplies
• Compact Rugged Construction
• Maximum Protection for EMP and Tempest applications
• Current Range 16 to 200 Amperes
• 100 dB Insertion Loss from 14 kHz to 40 GHz
• Low power dissipation

 

GENERATOR CAMP ELECTRIC ORIZONTAL/ VERTICAL 10 KHZ..30 MHZ ETS-LINDGREN 5502

• Generates vertical or horizontal electric field
• Generates Fields 200 v/m in the 10 kHz to 30 MHz Frequency Range
• Fully Adjustable Height and Separation of Main Conductors
• Large Immunity Volume
• Chamber Supported

 

SONDE MASURA CURENTI 10 KHZ..1000 MHZ ETS-LINDGREN

• 10 kHz..1000 MHz Frequency ranges
• For Standards Testing and Pre-compliance Applications
• Measures RF Current Without Direct Connection

 

FILTRE EMI DE PUTERE RETELE MONOFAZATE APLICATII TEMPEST/ EMC 32..120A ETS-LINDGREN N192X

• Current Range 32 to 250 Amperes
• Very High RF Attenuation
• Fully Tested for Attenuation Performance
• Durable Construction
• CE Marked

 

TESTER MASURA RADIATII CAMP ELECTROMAGNETIC EMISE DE MONITOARE VIDEO SI TERMINALE CU DISPLAY ETS-LINDGREN HI-3603

• VDT / VLF Survey Instrument
• Wide Dynamic Range
• On-Board Data Logging
• Combination E & H Readings

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5405

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

ANTENA HORN PENTRU MASURATORI EMC 18..40 GHZ ETS-LINDGREN 3116B

• Frequency Minimum 18 GHz
• Frequency Maximum 40 GHz
• VSWR Ratio (AVG) 2.5:1 max
• Maximum Continuous Power 20 W
• Peak Power 200 W
• Impedance (Nominal) 50 ?

 

DIPOL SFERIC UNIVERSAL GENERARE RADIATII ELECTROMAGNETICE EMI ETS-LINDGREN USDS

• Portable EMI Source for Quick Test Site Characterization and Site-to-Site Comparisons
• Horizontal and Vertical Polarizations
• Selectable Pulse Mode for Testing Quasi-Peak Detectors
• 10 MHz - 10 GHz Frequency Range
• Four Switch Selectable Fundamental Frequencies: 10 MHz, 64 MHz, 100 MHz,133 MHz

 

INTERFATA WIRELESS TESTARE TELEFOANE MOBILE IN COMUNICATII CELULARE ETS-LINDGREN 5211

• Works with Mobile/Cellular Radio Test Sets: HP 8924
• >80 dB Typical RF Isolation
• On-The-Air Test TX, RX Functionality Without Direct Cable connection to Cell Phone Data Port
• Flat Coupling Response over 700 MHz - 2 GHz

 

TESTER CAMP MAGNETIC 5..2000 HZ ETS-LINDGREN HI-3627

• 5 - 2000 Hz
• 0.2 mG - 20 G
• Three Concentric Orthogonal Field Sensors
• True RMS Detection
• Isotropic Response
• 100dB Dynamic Range