Cod: ETS-Lindgren 95236-1/ 95242-1
Descriere
The probe's operating frequency range is 10 kHz to 100 MHz. This probe is most efficient from about 15 kHz to 4 MHz. The 95236-1 probe cover the low frequency portion of RTCA/DO-160C RF conducted susceptibility requirements and MIL-STD-461D I MIL-STD-462D CS114 (10 kHz · Z MHz).
The Model 95236-1 probe has a 1.6" window, making it suitable for injecting current into most power or signal cables. (AWG 4/0 cable, good for several hundred Amps, is 12.7 mm (0.5 in) diameter, exclusive of insulation.) 100 Watts of cw RF power may be driven into the probe in the injection mode.
|
Frequency Minimum |
10 kHz |
|
Frequency Maximum |
100 MHz |
|
Maximum Power |
100 W |
It enables testing to be performed which previously required the use of two separate injection probes, the ERA type 36A and 37A This is our most efficient injection device from 4 MHz to almost 600 MHz The 95242-1 probe covers the high frequency portion of RTCA/DO-160C RF conducted susceptibility requirements and MIL-STD-461D I MIL-STD-462D CS114 (5 MHz - 400 MHz). This injection probe is also suitable for injecting the required current waveforms of MIL-STD-461D limits CS115 and CS116 (for CS116, one of our lower frequency probes is required as well). Testing to British Defense Standard DEF STA 59-41, Part 3 is also supported by this model. When necessary, our 95235-1 injection probe has larger 2.625" window diameter, but is less efficient than the 95242-1. When calibrating the Calibration Jig coupled current vs. forward power into the injection probe, the combination of 95242-1 probe and 95241-1 Jig has an excellent low VSWR.
The Model 95242-1 probe has a 1.6" window, making it suitable for injecting current into most power or signal cables. (AWG 4/0 cable, good for several hundred Amps, is 12.7 mm (0.5 in) diameter exclusive of insulation.) 100 Watts of cw RF power may be driven into the probe in the injection mode.
|
Frequency Minimum |
2 MHz |
|
Frequency Maximum |
400 MHz |
|
Maximum Power |
100 W |
Alte produse ETS-LINDGREN
|
ANTENA HORN PIRAMIDAL CU GENERARE CAMP ELECTRIC TESTARE EMC AUTO ES-XW7T-1A278-AC 2.7..3.1 GHZ ETS-LINDGREN 3162-02
• Frequency Minimum 2.7 GHz |
|
ANTENA LOG-PERIODICA DIRECTIONALA MASURATORI CISPR 16-1 BANDA 200 MHZ..2 GHZ ETS-LINDGREN 3148B
• Frequency Minimum 200 MHz |
|
ANTENA BICONICA MASURA DE PRECIZIE 30..300 MHZ ETS-LINDGREN 3110C
• Frequency Minimum 30 MHz |
|
ANTENA ACTIVA BUCLA DE RECEPTIE 10 KHZ..30 MHZ ETS-LINDGREN 6502
• Frequency Minimum 10 kHz |
|
DIPOL SFERIC UNIVERSAL GENERARE RADIATII ELECTROMAGNETICE EMI ETS-LINDGREN USDS
• Portable EMI Source for Quick Test Site Characterization and Site-to-Site Comparisons |
|
ANTENA SPIRALA CONICA LOGARITMICA 100 MHZ..1 GHZ ETS-LINDGREN 3103
• Frequency Minimum 100 MHz |
|
ANTENA DE BANDA LARGA OMNIDIRECTIONALA 1..18 GHZ ETS-LINDGREN 3183
• Frequency Minimum 1 GHz |
|
CELULA REVERBERANTA TESTE EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE RADIATA 1..40 GHZ ETS-LINDGREN SMART 1000
• Automated Measurement with Optional Software |
|
TESTER MASURA RADIATII CAMP ELECTROMAGNETIC EMISE DE CUPTOARE MICROUNDE ETS-LINDGREN HI-1501
• Three Ranges |
|
CELULA GTEM TEST, MASURA, INCERCARI EMISII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5405
• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1 |