BAUR DPA 75 C Oil breakdown voltage tester

Cod: BAUR DPA 75 C


 

Brosura produs PDF, 0.22 Mb

Descriere

The BAUR DPA 75 C oil tester developed especially for mobile use in the field is one of its kind in the market due to its functionality and excellent user benefits in comparison to the costs. The BAUR DPA 75 C delivers clear and reliable measurement results.

 

Features:

  • Compact and robust device for portable use onsite
  • Test voltages from 0 to 75 kVrms
  • Repeatable breakdown measurements in mineral, silicone and plant oils
  • Reliable measurement results due to its short switch-off time (< 10 ½s)
 

Alte produse BAUR

BAUR DTA 100 C OIL BREAKDOWN VOLTAGE TESTER

• Fully automatic measurement sequence
• Suitable for mineral or silicone oils and easther liquids
• Reliable, reproducible measurement results using the latest measument technology
• Designed for daily countinous operations in laboratories

 

BAUR PGK 70/2.5 HB HIGH-VOLTAGE TEST DEVICE

• Operation as DC or Ac testing device
• Polarity of the DC voltage can be easily be reserved
• Robust and durable

 

BAUR PGK 50E / PGK 80E DC HIGH-VOLTAGE TEST DEVICE

• Continuous adjustable output voltage
• The voltage measurement is done directly at the high voltage output
• Timer of 1-30 min
• Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal

 

BAUR SHIRLA CABLE SHEATH TESTING AND FAULT LOCATION SYSTEM

• Cable and cable sheath testing up to 10 kVC
• Resistance measurement
• Cable and cable sheath fault pre-location with precision measuring bridge
• Adjustable cable sections that can be defined with length, conductor cross-section and material respectively and can be considered in the distance calculation

 

BAUR ATG 6000 BURN DOWN TRANSFORMER

• Proven methodes for cable faults that are difficult to locate
• Useful for cables that are difficult to access
• Robust construction for reliable functions
• Independent current and voltage control on each burning level

 

BAUR KMF 1 SEARCH RECEIVER

• Battery mode
• Zero point compensation
• Accurate location of cable sheath faults
• Battery test

 

BAUR DPA 75 C OIL BREAKDOWN VOLTAGE TESTER

• Compact and robust device for portable use onsite
• Test voltages from 0 to 75 kVrms
• Repeatable breakdown measurements in mineral, silicone and plant oils
• Reliable measurement results due to its short switch-off time (< 10 ½s)

 

BAUR PGK 110/5 HB HIGH-VOLTAGE TEST DEVICE

• Testing as DC or Dc testing device
• Polarity of the DC voltage can easily be reversed
• Robust and durable

 

BAUR PHG 70 TD PD / PHG 80 TD PD VLF TEST AND DIAGNOSTICS SYSTEM

• Compact, enclosed design in 19½ format
• Variable installation option with separate control and voltage unit
• Variable connection options to cable stations of different models

 

BAUR VIOLA AND VIOLA TD HIGH-VOLTAGE TEST AND DIAGNOSTICS DEVICE

• High performance and compact
• Precise and non-destructive determination of the cable condition
• Easy and quick test setup
• Automatic testing and diagnostic sequences