Items |
Specifications |
Number of lines |
Single phase |
Test mode |
Interruption AC/DC |
Local |
Synchronous:Short circuit |
PC |
Synchronous: Short circuit/ Open circuit Asynchronous: Short circuit/ Open circuit |
Dip and swell |
Local |
Synchronous |
PC |
Synchronous/ Asynchronous |
Variation |
Local |
Asynchronous (Only 2s-1s-2s standard defined test is available.) |
PC |
Asynchronous |
Input voltage range |
AC90~264V, 50/60Hz, DC0~125V |
Output voltage range |
AC 0%~ 120% of input voltage, AC290V Max DC 0V-input voltage |
Output VA |
4.224KVA (Continuous) |
Output current capability |
AC |
100% of input voltage: 16A rms (Continuous)
80% of input voltage: 20A rms (<5S) 70% of input voltage: 23A rms (<5S) 40% of input voltage: 40A rms (<5S) |
DC |
16A (Continuous) |
Peak inrush current drive capability |
AC 100~ 120V: >250A (at 100% output, <10mS) AC 220 ~240V: >500A (at 100% output, <10mS) |
Load regulation |
100% of input voltage 0-16A rms: <5%
80% of input voltage 0-20A rms: <5% 70% of input voltage 0-23A rms: <5% 40% of input voltage 0-40A rms: <5% |
Overshoot/ undershoot |
<5% (100 ohm loaded) |
Rise time/ fall time |
1 ~ 5 µS (100ohm loaded) |
Normal voltage setting |
Setting by percent |
Local |
100% |
PC |
(4%) ~120% /10V minimum |
Setting by voltage |
PC |
10V~290V/ 5V step |
Accuracy |
±5V (0V~16A output) |
Dip/swell level |
Setting by percent |
Local |
Short circuit for 0% (Interruption), setting: 0/40/70/80/120% (5 steps) |
PC |
Short/Open selectable for 0% (interruption): 0~120% |
Setting by voltage |
PC |
Short/Open selectable for 0V (interruption): 0~290V(0~120%), 5 steps |
Accuracy |
±5V |
Repetition of events (No. of events) |
Local |
1,3, 5, 10, 30, 50,10, or continuous (8 steps) |
PC |
1~1,000 or continuous (1 event step) |
Interval cycle |
Setting by cycle |
Local |
1, 3, 5, 10, 30, 50, 100, 300, 500, cycles and 10s (10steps) |
PC |
0.5 ~ 5,000.5 cycles (0.5 cycle step) |
Setting by time |
Setting for short duration |
PC |
Synchronous: 1~100s (1s step) Asynchronous: 8.3ms~100s (0.1m step) |
Setting for long duration |
PC |
Asynchronous: 1s ~ 10h (1s step) |
Dip cycle |
Setting by cycle |
Local |
0.5, 1, 5, 10, 12, 25, 30, 50, 250, 300 cycles (10 steps) |
PC |
0.01 ~ 5,000 cycles (0.01 cycle step) |
Setting by time |
Setting for short duration |
PC |
Synchronous: 0.1ms~100s (0.1ms step) Asynchronous: 0.1ms~100s (0.1ms step) |
Setting for long duration |
PC |
Asynchronous: 1s ~ 10h (1s step) |
Dip phase (starting phase angle of events) |
Setting by phase angle |
Local |
Synchronous: 0,45,90,135,180,225,270,315 (8 steps, 45 degrees step) |
PC |
Synchronous: 0~359° (1° step) |
Setting by time |
PC |
Synchronous: 0~19.9 ms for 50 Hz (0.1ms step) 0~16.6 ms for 60 Hz (0.1ms step) |
Voltage variation test |
Setting by time |
PC |
Ansynchronous: Changing time: 0.1s~10s (0.1s step) , At least 0.1s required for 10% change of input Changed time: 0~10s (0.1s step) Interval: 0~100s (0.1s step) Test level: 0~120% |
Memory |
Local |
5 tests |
PC |
10 steps (Test sequence stored up to 10 steps when controlled by PC.) |
Equipment Input voltage |
AC100~240V ±10%, 50/60Hz, 120VA |
External interface |
Optical RS-232 |
Dimensions |
430(W) x 745(H) x 600 (D) mm (Projection excluded) |
Weight |
Approx. 150 kG |