Code: Vanguard VBT-60 / VBT-80
Description
VBT-60/VBT-80
vacuum bottle testers
The VBT-60 and VBT-80 are microprocessor-based, portable, dc (60 kV and 80
kV, respectively) vacuum bottle testers. These lightweight, portable testers are
designed for testing circuit-breaker vacuum bottles in the fi eld and at the shop.
Test voltages can be selected from 10 kV dc to 60 kV dc in 5 kV steps for the
VBT-60 and from 10 kV to 80 kV dc in 5 kV steps for the VBT-80. The high-voltage
test time can be set from 5 seconds to 2 minutes. The test voltage is raised
to the selected voltage and held for the test time duration. After the test time
duration has elapsed and the leakage current did not pass the preset value of
100 µA, 200 µA, or 300 µA, the test voltage is returned to zero. If a fl ash-over
condition occurs, such as bottle failure, the test voltage is immediately turned
off, a "Failure" message is displayed on the LCD screen, and the "TEST FAIL" LED
light on the unit is also illuminated.
The presence of high voltage is indicated by an audible tone and an illuminated
"HIGH VOLTAGE" LED light. For additional operator safety, an "ARM" switch
must be held down during testing.
The VBT-60 and VBT-80 feature a back-lit LCD screen (16 characters by 2 lines)
that is viewable in both bright sunlight and low-light levels. A turn-and-press
knob is used to control the unit. An RS-232C interface port is provided for factory
calibration and diagnostic testing.
Each unit is furnished with a 10-foot test cable that is terminated with a quickdisconnect
test clip. A transportation case is also included.
Standard accessories
Part number VBT-60 VBT-60 and cables
Part number VBT-80 VBT-80 and cables
Part number VBT-HV-CABLE Hight Voltage Cable
More products VANGUARD
|
THREE-PHASE TRANSFORMER WINDING RESISTANCE METER VANGUARD TRM-20
• accurately measure resistance from 1 micro-ohm to 2000 Ohms |
|
TRANSFORMER WINDING RESISTANCE TESTER VANGUARD TRM-40
• accurately measure resistance values from 1 micro-ohm to 500 Ohms |
|
10A AC/DC CURENT POWER SOURCE FOR TESTING CIRCUIT BREAKERS AND PROTECTIVE RELAYS VANGUARD UPS-S2
• Isolated variable 1-300 Vdc source |
|
TRUE THREE-PHASE TRANSFORMER TURN RATIO TESTER VANGUARD TRI-PHASE
• Generates its own 3-phase transformer test voltage from single-phase AC or DC Power input |
|
EHV HIGH VOLTAGE CIRCUIT BREAKER ANALYZER VANGUARD DIGITMR
• dry-contact inputs 3 dry-contact channels |
|
PORTABLE RELAY TEST SET VANGUARD RFD-200
• Timer: 0 to 9.999 sec, 1 ms resolution; 10.00 to 99.99 sec, 10 ms resolution, 100.00 to 999.999 sec, 100 ms resolution |
|
EHV HIGH VOLTAGE CIRCUIT BREAKER ANALYZER VANGUARD DIGITMR PC
• dry-contact inputs 3 dry-contact channels |
|
TRANSFORMER TURN RATIO TESTER VANGUARD ATRT-01
• Displays turns-ratio from 0.8-15,000 |
|
DIGITAL BREAKER ANALYZER FOR CONTACT & SWITCH TIMING VANGUARD CT-3500
• Dry-contact inputs: 3 channels |
|
DC AUTOMATIC CIRCUIT BREAKER CONTACT RESISTANCE MICRO-OHMMETER 200A VANGUARD AUTO-OHM 200 S3
• 1 to 200A programmable test current |