Radiometric Probe for Outdoor measuring of Solar Irradiance Delta Ohm LP UVA02

Code: Delta Ohm LP UVA02 LP UVA02AC LP UVA02AV


 

Datasheet PDF, 0.67 Mb

Description

Radiometric probe for outdoor use for measuring IRRADIANCE in the range UVA (315...400nm).
mV per mW/cm2 output.
Complete with Calibration Report.
On request 5 or 10m cables with connectors
 

More products SENSECA

PLUVIOMETER RAIN GAUGE FOR ATMOSFERIC PRECIPITATION DELTA OHM HD2013

• Rain gauge with tipping bucket,
• area 400cm2,
• for temperature range +4°C... +60°C.
• Standard resolution 0.2.
• On request at the time of placing the order resolution 0.1 or 0.5mm.
• Output contact normally closed.

 

LUXMETER PHOTO- RADIOMETER MEASURING SOLAR ILLUMINANCE, PAR, IRRADIANCE DELTA OHM HD2102.1 HD2102.2

• Device for measuring illuminance, luminance, PAR, irradiance.
• Storage of maximum, minimum, average value and the integral Q(t),
• RS232 C output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

HANDHELD DIGITAL THERMOCOUPLE THERMOMETER K, J, T, R, N, S, B, E DELTA OHM HD2108.1 HD2108.2 HD2128.1 HD2128.2

• Thermocouple thermometer with one input and logger 32.000 samples
• For K, J, T, R, N, S, B, E type probes with miniature connector
• Storage of maximum, minimum, average value,
• USB/RS232 C connection to download loggerdata to PC.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

RADIOMETRIC PROBE FOR OUTDOOR MEASURING OF SOLAR IRRADIANCE DELTA OHM LP UVA02

• Radiometric probe for outdoor use for measuring IRRADIANCE in the range UVA (315...400nm).
• mV per mW/cm2 output.
• Complete with Calibration Report.
• On request 5 or 10m cables with connectors

 

NET RADIOMETER WITH 4-COMPONENTS FOR SOLAR RADIATION MEASUREMENTS DELTA OHM LP NET14

• LP NET 14 is a 4-component net-radiometer for the measurement of the net radiation between 0.3µm and 45 µm.
• consists of two pyranometers: one for the measurement of the global radiation Esw? and the other one for the measurement of the reflected solar radiation Esw?
• pair of pyrgeometers: one for the measurement of the infrared radiation emitted by the sky EFIR? and the other one for the infrared emitted by the ground surface EFIR?
• equipped with a temperature sensor (NTC).

 

THREE-AXIS ULTRASONIC ANEMOMETER FOR WIND SPEED & DIRECTION MEASUREMENT DELTA OHM HD2003 HD2003.1

• Determination of the anemometric quantities represented in diverse measurement units:
• wind speed and direction,
• U-V-W Cartesian components of speed,
• sound speed,
• sonic temperature
• 5 analogue voltage or current outputs, with different measuring ranges.
• RS232 and Multidrop RS485 Serial Communication interfaces.

 

AIR QUALITY ANALYSIS MONITORING DATALOGGER CO CO2 DELTA OHM HD37AB17D HD37B17D

• data loggers able to measure and memorize simultaneously the following parameters:
• Relative Humidity RH
• Environment temperature T
• Carbon monoxide CO (only HD37AB17D)
• Carbon dioxide CO2
• DeltaLog13 communication software via the USB port

 

THREE-CHANNEL VIBRATION ANALYZER FOR WORKERS PROTECTION DELTA OHM HD2070

• portable vibration analyzer performing spectral and statistical analysis on three channels simultaneously
• measures all parameters required by current regulations concerning workers protection from vibration related risks
• measure vibrations transmitted to both hand-arm and whole body
• simplicity of use with maximum flexibility
• possibility of updating the instrument according to the evolution of the regulations relating to vibration measurement
• Octave and third octave filters, available as option (HD2070.O1), satisfy class 1 specifications of IEC 61260 standard

 

FIRST CLASS PYRHELIOMETER FOR DIRECT SOLAR IRRADIANCE MEASUREMENT DELTA OHM LP PIRHE16

• The pyrheliometer LP PYRHE 16 First Class Pyrheliometer according to ISO 9060 classification
• is an instrument for direct measurement of solar irradiance (Watt/m2).
• The receiving surface must be positioned (via a solar tracker or else) perpendicularly to sun’s rays.
• By using suitable diaphragms only the direct light reaches the surface of the sensor.
• According to WMO (Seventh Edition 2008) and ISO 9069 regulations, the pyrheliometer has a field of view of 5°.

 

LUXMETER RADIOMETER MEASURING ILLUMINANCE, PAR, IRRADIANCE DELTA OHM HD2302.0 HD2302.0VP474

• Device for measuring illuminance, luminance, PAR, irradiance
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree