Seba KMT LPD Monitor On-line PD Partial Discharge Monitoring System for MV and HV

Code: Seba-KMT LPD-Monitor


 

Datasheet PDF, 0.3 Mb

Description

Bene?ts

  Portable online PD measuring system for monitoring MV and HV systems

  16 channels

  Allows ef? cient forward planning of  necessary maintenance work

  Quick and easy to install

  Integrated automatic knowledge-based evaluation of measured PD levels

  Current status can be viewed at any time  via remote access

 

Description

The LPD (live partial discharge) Monitor can be used for temporary

or constant monitoring of partial discharge on medium- and highvoltage

systems andcables  up to a rated voltage of 66 kV.

With its 16 input channels, the lightweight LPD Monitor is an ideal,

portable system for a fast check of critical PD within cables or their

accessories.

Even a quick test can provide useful information on the condition of

the cable as a basis for identifying the required maintenance work,

such as a comprehensive offline PD diagnosis.

The PD signals are recorded using inductive (HFCT) and/or capacitive

(TEV) sensors. The inductive sensors are placed directly around the

insulated conductor or the cable sheath. The capacitive sensors can

be easily attached to metal parts of the switchgear using a magnetic

holder.

Depending on the number of sensors, the signals from each sensor

are recorded at set intervals (every 1 to 20 minutes). These readings

are immediately analysed by the integrated software. The signals are

categorised either as a "local PD" or a "cable PD". The measured

level is compared to the values stored in a database and then assigned

to one of four possible assessment categories.

PD activity rated as"critical" automatically generates an alarm

message.

The user can check the current readings and the progress of the

PD activity at any time via remote access.

 

Standard accessories

Scope of delivery

 LPD Monitor

 6 inductive sensors (HFCT 100/50)

 2 capacitive sensors (TEV)

 Set of coaxial cables (2×5 m, 4×10 m and 2×15 m)

 Accessory bag

 Keyboard/mouse/modem

 

Recommended options

Options

 Set of additional sensors (6 x HFCT 100/50, 2 x TEV)

 Different-sized HFCT sensors (ask SebaKMT for details)

 Flat coaxial cables for enclosed switchgears

 

 

More products SEBAKMT

SEBA SURGEFLEX SFX-15 SFX-25 CABLE FAULT LOCATING SYSTEM

• » DC-Testing up to 15 kV / 25 kV (depending on model)
• » Prelocating
• » - Reflection measurement
• » - ARM-Measurement (Arc reflection method)
• » - ICE Impulse current method
• » Cable tracing (optional)
• » Pin-pointing
• » - Distance and acoustic measurement
• » - Audio frequency methods (optional)
• » Battery and mains operation

 

SEBA KMT SEBALOG N-3 AUTOMATIC WATER LEAK LOCATION WITH CORRELATING NOISE LOGGER NETWORK

• Latest measured data available every day
• Correlation function
• No time-consuming driving past individual loggers
• Remote configuration
• Very simple installation process
• Cost-effective data transmission

 

SEBA KMT KMK 8 COMMUNICATIONS NETWORK CABLE TESTER

• Integrated Reflectometer (TDR)
• Active bridge for high precision R and C measurements and DC and AC fault location
• Measurement by Graaf method in connection with an active slave at the far end
• Passive Wheatstone bridge for R and C measurements and DC and AC fault location
• Test Systems for Pre-measurement, Quick test and Quality testing
• Measurement of interference voltages
• Warning and information system
• Remote control for the operation of the electronic far end loop control switch

 

SEBA KMT CDS CABLE DIAGNOSTIC SYSTEM FOR THREE PHASE IRC AND RVM DIAGNOSTICS

• Absolutely non-destructive condition evaluation of PE / XLPE / paper-oil insulated cable systems
• Simple operation and automatic measurement procedures
• Three-phase parallel measurement for current and voltage - duration of a complete measurement 1 hour
• Extended dynamic range for IRC measurement for long cable segments
• Measurement of charging current during formation

 

SEBA SWG 505 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG505

• Voltage Ranges : 0.. 3kV / 4kV / 5kV
• Energy : 180J / 320J / 500J
• MAx Current Imax : 129mA / 182mA / 213mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method

 

SEBA KMT HPA 100 AC HPA 130 DC BURNDOWN HIGH VOLTAGE TESTING

• Powerful test- and burning system
• Continuous testing with AC voltages up to 100 kVrms at 5 kVA
• Own noise-level below 1 pC
• Built-in overcurrent protection
• DC testing up to 130 kV with optional rectifier

 

SEBA KMT GEOLUX GL 660-1 EARTH FAULT LOCATOR FOR FAULT LOCATION IN ISOLATED, EARTH FREE SYSTEMS

• Earth fault locator for fault location in isolated, earth free systems
• Mains filter for direct coupling to live cables up to 660 V
• Pulsed output current for easier detection of the test signal
• Filter for the suppression large interference signals
• Location of earth faults up to 150 kOhm
• No switch off during the fault location required
• No influence to the signal lines connected to

 

SEBA KMT VFL SINUS 34KV 0.1HZ SINE WAVE CABLE TEST SYSTEMS

• High test capacity of 5 µF
• Suitable for outdoor use (IP 54)
• Single-button operation easyGO
• Integrated safety system
• Reporting
• Continuous duty cycle

 

SEBA KMT LPD MONITOR ON-LINE PD PARTIAL DISCHARGE MONITORING SYSTEM FOR MV AND HV

• Portable online PD measuring system for monitoring MV and HV systems
•  16 channels
•  Allows ef? cient forward planning of necessary maintenance work
•  Quick and easy to install
•  Integrated automatic knowledge-based evaluation of measured PD levels
•  Current status can be viewed at any time via remote access

 

SEBA KMT FERROLUX FLE 10 AUDIO FREQUENCY RECEIVER FOR CABLE LOCATION, SELECTION, SHEATH FAULTS

• Precise direction guidance with right/left arrows
• "SignalSelect" for clear route location
• Depth and signal current intensity measurement at the push of a button
• Route sensor weighs less than 1 kg for non-tiring use
• "DirectSignal" for effective line location