Seba KMT LPD Monitor On-line PD Partial Discharge Monitoring System for MV and HV

Code: Seba-KMT LPD-Monitor


 

Datasheet PDF, 0.3 Mb

Description

Bene?ts

  Portable online PD measuring system for monitoring MV and HV systems

  16 channels

  Allows ef? cient forward planning of  necessary maintenance work

  Quick and easy to install

  Integrated automatic knowledge-based evaluation of measured PD levels

  Current status can be viewed at any time  via remote access

 

Description

The LPD (live partial discharge) Monitor can be used for temporary

or constant monitoring of partial discharge on medium- and highvoltage

systems andcables  up to a rated voltage of 66 kV.

With its 16 input channels, the lightweight LPD Monitor is an ideal,

portable system for a fast check of critical PD within cables or their

accessories.

Even a quick test can provide useful information on the condition of

the cable as a basis for identifying the required maintenance work,

such as a comprehensive offline PD diagnosis.

The PD signals are recorded using inductive (HFCT) and/or capacitive

(TEV) sensors. The inductive sensors are placed directly around the

insulated conductor or the cable sheath. The capacitive sensors can

be easily attached to metal parts of the switchgear using a magnetic

holder.

Depending on the number of sensors, the signals from each sensor

are recorded at set intervals (every 1 to 20 minutes). These readings

are immediately analysed by the integrated software. The signals are

categorised either as a "local PD" or a "cable PD". The measured

level is compared to the values stored in a database and then assigned

to one of four possible assessment categories.

PD activity rated as"critical" automatically generates an alarm

message.

The user can check the current readings and the progress of the

PD activity at any time via remote access.

 

Standard accessories

Scope of delivery

 LPD Monitor

 6 inductive sensors (HFCT 100/50)

 2 capacitive sensors (TEV)

 Set of coaxial cables (2×5 m, 4×10 m and 2×15 m)

 Accessory bag

 Keyboard/mouse/modem

 

Recommended options

Options

 Set of additional sensors (6 x HFCT 100/50, 2 x TEV)

 Different-sized HFCT sensors (ask SebaKMT for details)

 Flat coaxial cables for enclosed switchgears

 

 

More products SEBAKMT

SEBA KMT BT 500 IS-1 CABLE FAULT CONVERTER

• Overload protection
• Automatic discharge
• Burning of high resistive faults
• Low- potential free voltage avoids damage to other conductors
• Adjustable current limiter

 

SEBA KMT VFL CR-20 VERY LOW FREQUENCY CABLE TESTING SYSTEM

• VLF Test System 20 kV
• high test capacity of 3 µF permits the simultaneous testing of all three phases
• method is officially recommended by the two VDE Standards 0276-620 and 0276-621
• VLF is the most economic method for testing PE and XLPE cables

 

SEBA BPS 5000-D BURN AND PROOF TEST SYSTEM ON MEDIUM VOLTAGE CABLES BPS-5000D BPS500D BPS 5000D-VLF

• Easy-go single button operation
• Protocolling of the test results
• Data transfer via Bluetooth
• DC burn current up to 6 A
• AC burn current up to 110 A
• Sheath fault pinpoiting mode

 

SEBA FAULT SNIFFER FOR DETECTION OF BURNING GASES FROM FAULT CABLES UNDERGROUND

• Customers can stay connected
• Fault location with no supply interrupt
• Reliable avoidance of incorrect excavations
• Fast and easy location of faults
• Can be used on straight or branched networks
• Handy size, easy to transport
• No pre-location required
• Accuracy in the decimetre range
• Sensitive to several specifi c gases and therefore suitable for any insulation material

 

SEBAKMT CORRELUX C-3 HYBRID LEAK NOISE CORRELATOR, ONLINE AND OFFLINE

• Precise leak detection
• State-of-the-art sensor technology
• Online and offline correlation
• Simple operation
• Robust design

 

SEBA KMT OWTS M60 DIELECTRIC DIAGNOSIS AND PARTIAL DISCHARGE MEASURING SYSTEM

• PD diagnosis under oscillating wave test voltage
• PD evaluation possibility and pattern recognition at the nominal voltage level
• Automatic Calibration and Joint location facility
• PD level measurement according to IEC 270 at a bandwidth of 150 ... 650 kHz
• Semi- and fully automatic PD analysing software for defect location with mapping feature
• Calculation of the cable capacitance and the tan delta value
• Simple to use and easy to handle menu-driven unit for operation of the test sequence
• Compact design; low weight

 

SEBA KMT VFL SINUS 34KV 0.1HZ SINE WAVE CABLE TEST SYSTEMS

• High test capacity of 5 µF
• Suitable for outdoor use (IP 54)
• Single-button operation easyGO
• Integrated safety system
• Reporting
• Continuous duty cycle

 

SEBA KMT HPG 50..80-D DC & AC HIGH VOLTAGE CABLE TESTER

• HPG 50-D, AC testing up to 35 kVRMS/ DC testing up to 100 kV
• HPG 70 / 80-D, AC testing up to 50 / 58 kVRMS / DC testing up to 140 / 150 kV
• Suitable for AC testing and DC testing
• Compact, cast-resin high-voltage transformers
• Separate control and HV-units
• Voltage continuously adjustable
• Powerful system: 1,2 kVA continuous operation, up to 3 kVA 60 min. short-time operation

 

SEBA SWG 1750 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG1750 SWG1750C SWG1750CI SWG1750C-4 SWG1750CD

• Voltage Ranges : 0.. 8kV / 0..16kV / 0..32kV
• SWG 1750C with 8 - 16 - 32 kV / 1750 J
• SWG 1750 CI with 8 - 16 - 32 kV / 1750 J, incl. leakage current measurement
• SWG 1750 C-4 with 2 - 4 kV / 1150 J and 8 - 16 - 32 kV / 1750 J
• SWG 1750 CD with 8 - 16 - 32 kV / 3500 J

 

SEBA KMT PIL 8 PHASENLUX PHASE IDENTI?CATION IN EARTHED AND SHORT-CIRCUITED MEDIUM VOLTAGE CABLES

• Maintenance free transceiver clamps
• Suitable for any type of switch gear
• Requires only one person
• Easiest operation
• Absolute safe phase identification