Static / dynamic resistance measurement accessory for TM Series Megger - SDRM202

Code: Megger - SDRM202


 

Datasheet PDF, 0.88 Mb

Description

The SDRM202 is an accessory for TM1800 and TM1700. SDRM202 can be used with EGIL equipped with the SDRM option and CABA Win version R03A or higher, however the single channel SDRM201 is recommended.

 

The SDRM202 is intended to use for both static and dynamic resistance measurements (SRM and DRM) on high voltage circuit breakers or other low resistive devices. Used together with TM1800 and TM1700 the current and also the voltage-drop across the circuit breaker contacts are measured. The measuring unit can thus calculate the resistance as a function of time.

 

An SDRM202 unit includes current cables and an SDRM Cable which comes in three versions, for TM1800 and TM1700 and EGIL respectively. The SDRM Cable is a small box with integrated cables for connection to the SDRM202 and to TM1800, TM1700 or EGIL.

 

Features:

  • Enables resistance measurement on circuit breakers
  • Small and light weight
  • A number of operations can be run with short waiting intervals
 

Recommended options



 

More products MEGGER

MEGGER - MS2A CIRCUIT BREAKER AND OVERCURRENT RELAY TEST SET

• Light Weight, Portable Primary Injection Test Instrument
• Overcurrent Relay Testing
• Ground Fault Performance Testing for NEC 230.95
• Circuit Breaker Testing

 

DUAL POWER MICRO-OHMMETER MEGGER DLRO10HDX DUCTER

• Interchangeable test lead terminations
• High or low output power selection for condition diagnosis
• Operates from battery or AC mains supply
• Protected to 600 V without blowing a fuse, test lead live voltage warning light

 

MEGGER MPRT2145 SINGLE PHASE RELAY TESTER

• Open communication architecture for third party software application
• Small, rugged, lightweight and powerful
• Operate with or without a computer
• Intuitive manual operation with Smart Touch View Interface
• High current, high power (60 amps/400 VA rms)
• Network interface provides IEC 61850 test capabilities
• Fully automated testing using AVTS software

 

MEGGER SVERKER900 THREE PHASE RELAY TESTER

• The toolbox for substation 3-phase testing
• Three currents and four voltages
• Stand-alone functionality
• Rugged and reliable for field use
• Generation of 900 V and 105 A in single phase mode
• Secondary and primary testing

 

MEGGER S1-568/2 EXPERT 5000V 5KV INSULATION RESISTANCE MEGOHMMETER

• Reliable results in noisy substations
• Accurate testing with RE>Act™
• Remote control for safer, easier testing
• PI Predictor™ cuts test time in half
• Full diagnostic suite with PDC capability

 

MEGGER MIT400/2 MIT410/2 MIT420/2 MIT430/2 CAT IV INSULATION TESTER WITH 1000V

• nsulation testing up to 1000 V and 200 GΩ range
• Stabilised insulation test voltage (New)
• Single range, faster continuity testing from 0.01 Ω to 1 MΩ (New)
• 600 V T RMS AC and DC voltage measurement

 

MEGGER MPAC208 ACOUSTIC CAMERA FOR GAS LEAKS, MECHANICAL FAULTS AND PARTIAL DISCHARGES

• Pinpoint issues fast
• Quantify leak and energy loss
• Reliable PD insight
• Works in noisy environments
• Optional thermal overlay
• Available in comprehensive kit

 

MEGGER TDR2000/2 TDR CABLE REFLECTOMETER FAULT LOCATOR TDR2000/2RM TDR2000/2R

• 20 km range at VF = 0.90
• Monochrome or colour options
• Primary cell or rechargeable options
• Large back lit LCD Display
• Dual cursor measurement
• Intermittent fault location
• Output pulse amplitude and width control
• Trace Master PC software included
• IP54 Rating
• 2 year Warranty

 

MEGGER OTS60AF OTS80AF OTS100AF OIL BREAKDOWN TESTER 60KV 80KV 100KV

• Test voltages : 60 kV, 80 kV and 100 kV
• Laboratory instruments for measuring insulating oil breakdown voltage
• Lock in precision - oil vessel with lockable adjustment
• Bright 3.5" colour display
• Suitable for mineral, ester and silicon oils
• Trip detection circuit with direct measurement of voltage and current
• Ultra fast (< 10 µs) HV switch off time

 

MEGGER MIT480/2 MIT481/2 MIT485/2 INSULATION TESTER FOR COMMUNICATIONS 500V

• Insulation testing up to 500 V and 100 GΩ range in a hand held instrument
• 3-wire connection for A, B, and E (Tip, Ring and Ground/Earth) connection
• Gated access to 500 V to prevent accidental damage
• CAT IV 600 V and IP 54