Description
Description
Model M133C is compact one-housing three phase electric power/energy calibrator. It can supply unit under test with one phase accurate AC voltage and current with calibrated phase shift or DC voltage and current. Output voltage can be set in six ranges up to 600 V and output current in six ranges up to 30 A. Simulated electric power can be set independently in each phase. Frequency can be set in range from 15 Hz to 1 kHz with resolution 0.001 Hz to 0.01 Hz. Calibrator is equipped with 5 1/2 digital DC meter with DC ranges 20 mA or 10 V for direct calibrating of various types of power transducers.
M133C calibrator offers two types of defined distortion of main sinusoidal output signal. The first distortion is based on adding defined amount of harmonic or interharmonic spectral components up to 5 kHz. The second type of distortion is based on amplitude modulation of output sinusoidal signal by sin or squarewave modulation signal in frequency range from 0.001 Hz to 50 Hz. Maximum depth of modulation is 30 %.
Using supplied cable adapter the current outputs can be joined together offering one phase current range to 90 A AC/DC.
M133 control panel facilitates setting of power energy calibrators series M133. It is possible to set all three phase channels and also waveforms of individual voltage (current) outputs. Setting of harmonic / interharmonic components, modulation and Dip/Swells is displayed in simple chart.
Standard accessories
Recommended options
More products MEATEST
|
PRECISION PROGRAMMABLE RESISTANCE DECADE BOX MEATEST M630
• Resistance range 1.000 00 O - 1.200 000 MO |
|
HIGH CURRENT CALIBRATOR FOR CLAMP METERS MEATEST M151
• Current 8 mA … 120 A (AC/DC) |
|
UNIVERSAL MULTIFUNCTION CALIBRATOR MEATEST M141
• 100ppm Accuracy |
|
CAPACITANCE DECADE FOR CALIBRATION LCR-METERS MEATEST M520
• Designed for RCL meters calibration |
|
POWER AND ENERGY CALIBRATOR MEATEST M133
• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac |
|
RESISTIVE DECADE BOX MEATEST M602
• Resistance range from 0.1 O to 10 MO with accuracy 0.02 % |
|
PRECISION LABORATORY CALIBRATOR FOR METROLOGY MEATEST M140I
• 35ppm Accuracy |
|
HIGH PRECISION MULTIFUNCTION CALIBRATOR MEATEST M142
• 15ppm Accuracy |
|
HIGH RESISTANCE DECADE FOR CALIBRATION OF MEGOHMMETERS AND INSULATION METERS 5KV MEATEST M191
• Calibration of insulation meters and megaohm meters |
|
RF RESISTANCE STANDARD FOR CALIBRATION OF LCR METERS MEATEST M530
• Resistance range 10 O to 1000 O |