Three-Phase Power & Energy Calibrator Meatest M133C

Code: Meatest M133C


 

Datasheet PDF, 0.5 Mb

Description

  • Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
  • AC voltage "phase - phase" 2 V to 1200 V
  • DC/AC current 8 mA to 30 A / 5 V
  • DC/AC current 90 A in one phase configuration
  • Power factor setting -1 to +1
  • Floating current outputs to 450 Vpk
  • Harmonic, interharmonic distortion, modulation
  • Frequency range 15 Hz to 1 kHz
  • Simulated electric power to 54 kVA (2.7 MVA with option 140-50)
  • Built-in process multimeter
  • GPIB & RS232 interface

 

Description

Model M133C is compact one-housing three phase electric power/energy calibrator. It can supply unit under test with one phase accurate AC voltage and current with calibrated phase shift or DC voltage and current. Output voltage can be set in six ranges up to 600 V and output current in six ranges up to 30 A. Simulated electric power can be set independently in each phase. Frequency can be set in range from 15 Hz to 1 kHz with resolution 0.001 Hz to 0.01 Hz. Calibrator is equipped with 5 1/2 digital DC meter with DC ranges 20 mA or 10 V for direct calibrating of various types of power transducers.

M133C calibrator offers two types of defined distortion of main sinusoidal output signal. The first distortion is based on adding defined amount of harmonic or interharmonic spectral components up to 5 kHz. The second type of distortion is based on amplitude modulation of output sinusoidal signal by sin or squarewave modulation signal in frequency range from 0.001 Hz to 50 Hz. Maximum depth of modulation is 30 %.

Using supplied cable adapter the current outputs can be joined together offering one phase current range to 90 A AC/DC.

M133 control panel facilitates setting of power energy calibrators series M133. It is possible to set all three phase channels and also waveforms of individual voltage (current) outputs. Setting of harmonic / interharmonic components, modulation and Dip/Swells is displayed in simple chart.

 

 

Standard accessories

  • Power supply cable 1 pc
  • Operation manual, CD 1 pc
  • Option 10 Test cable banana-banana 1000V - 32 A, black 3 pcs Length 1m
  • Option 11 Test cable banana-banana 1000V - 32 A, red 3 pcs Length 1m
  • Option 12 Test cable banana-banana 1000V - 32 A, blue 3 pcs Length 1m
  • Option 13 Test cable banana-banana 1000V - 32 A, yellow 3 pcs Length 1m
  • Spare fuse 1 pc
  • RS 232 cable 1 pc Length 1.5m
  • M133C-01 High Current Adapter 1 pc
 

Recommended options

  • Option 140-50 Current coil 25/50 turns For clamp ammeters
  • Option 10 Test cable banana-banana 1000V - 32 A, black Length 1m
  • Option 11 Test cable banana-banana 1000V - 32 A, red Length 1m
  • Option 12 Test cable banana-banana 1000V - 32 A, blue Length 1m
  • Option 13 Test cable banana-banana 1000V - 32 A, yellow Length 1m
  • GPIB cable GPIB interface cable Length 1 m
  • RS-232 cable RS-232 interface cable Length 1.5 m
  • POWER Application SW. Transducers calibration.
 

More products MEATEST

PRECISION PROGRAMMABLE RESISTANCE DECADE BOX MEATEST M630

• Resistance range 1.000 00 O - 1.200 000 MO
• Accuracy 0.003%
• Maximal voltage 200Vpk
• Resolution from 10 µO
• Range of Pt sensor temperature simulation -200°C - +850°C
• Connection 2, 3, 4-wire
• Remote control RS232, optionally USB, IEEE488, Ethernet

 

HIGH CURRENT CALIBRATOR FOR CLAMP METERS MEATEST M151

• Current 8 mA … 120 A (AC/DC)
• Frequency 15 Hz … 1 kHz
• Simulated current and transconductance amplifier
• Built-in process multimeter
• Output capability 8 Vpk
• Interface bus GPIB and RS232 as standard
• With current coil it can be used for calibration of clamp meters up to 3000 A

 

UNIVERSAL MULTIFUNCTION CALIBRATOR MEATEST M141

• 100ppm Accuracy
• DC/AC voltage up to 750 V
• DC/AC current up to 2 A
• Fix standard resistors from 10 O to 10 MO in decade values
• TC temperature sensors simulation
• Frequency output up to 20 MHz
• RS232 & GPIB (option) interface

 

CAPACITANCE DECADE FOR CALIBRATION LCR-METERS MEATEST M520

• Designed for RCL meters calibration
• Range of capacitance from 100 pF to 12 mF
• Basic accuracy 0.25 %
• Maximal operating voltage 50 V
• Power supplying from internal battery or power line adapter
• Remote control RS-232

 

POWER AND ENERGY CALIBRATOR MEATEST M133

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" in the 3phase system 2 V to 1200 V
• DC/AC current 8 mA to 30 A / 5 V
• Power factor setting -1 to +1
• Harmonic, interharmonic distortion, modulation
• Frequency range 15 Hz to 1 kHz
• Simulated electric power to 8.4 kVA (420 kVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

RESISTIVE DECADE BOX MEATEST M602

• Resistance range from 0.1 O to 10 MO with accuracy 0.02 %
• Temperature coefficient < 25 ppm/°C
• Max. load 2 W (120 V and 0.6 A)
• RTD (Pt, Ni) simulation with accuracy 0.2 °C
• Power supplying from power line adaptor or from internal battery
• Interface RS232 (IEEE488 optionally)
• Table version (19" module as option)

 

PRECISION LABORATORY CALIBRATOR FOR METROLOGY MEATEST M140I

• 35ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 20 A
• TC temperature sensors simulation
• RS232 interface

 

HIGH PRECISION MULTIFUNCTION CALIBRATOR MEATEST M142

• 15ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 30 A
• Resistance up to 1000 MO, capacitance up to 100 uF
• TC/RTD temperature sensors simulation
• Frequency output up to 20 MHz
• Electric power up to 240 V / 20 A
• Built-in process multimeter
• GPIB & RS232 interface

 

HIGH RESISTANCE DECADE FOR CALIBRATION OF MEGOHMMETERS AND INSULATION METERS 5KV MEATEST M191

• Calibration of insulation meters and megaohm meters
• Four decades
• Resistance range 1 MO - 12 GO
• Accuracy from 0.1 % to 1 %
• Maximum working voltage 5 kVdc
• Internal battery / power line adapter supplying
• RS232 bus

 

RF RESISTANCE STANDARD FOR CALIBRATION OF LCR METERS MEATEST M530

• Resistance range 10 O to 1000 O
• Very low frequency dependency
• Applicable frequency range to 100 MHz
• Calibration of wide frequency range LCR meters