Agilent 81160A Pulse Function Arbitrary Noise Generator 500 MHz

Code: Agilent 81160A


 

Datasheet PDF, 1.18 Mb

Description

  • 1 µHz - 330 MHz pulse generation with variable rise/fall time
  • 1 µHz - 500 MHz sine waveform output
  • 14-bit, 2.5 GSa/s arbitrary waveforms
  • 1 or 2 channel, coupled and uncoupled
  • 256k samples deep arbitrary waveform memory per channel
  • Pulse, sine, square, ramp, noise and arbitrary waveforms
  • Noise, with an adjustable crest factor, and signal repetition time of 20 days
  • Differential outputs
  • FM, AM, PM, PWM, FSK modulation capabilities
  • Glitch free change of timing parameters
  • (delay, frequency, transition time, width, duty cycle)
  • Programming language compatible with Agilent 81101A, 81104A, 81105A , 81110A,
  • 81130A and 81150A
  • ISO 17025 and Z540.3 calibration
  • LXI class C compliant
  • Optional pattern generator:
  • Ideal and arbitrary bit shaped pattern up to 330 Mbit/s (Option 330) or 660 Mbit/s
  • (Option 660)
  • Three level signals
  • PRBS up to 231
  • 4 Mbit pattern memory for the 1-channel instrument and 2 Mbit per channel for the
  • 2-channel instrument
  • Pass through pattern for combined and physical and protocol test up to 10 Mbit/s
 

Standard accessories

  •  Certificate of calibration
  •  Local power cord
  •  USB cable
  •  Agilent automation ready CD (Agilent I/O Library, IVI-COM driver)
  •  Product CD (user guide, getting started guide)
 

Recommended options

Options:

  • Opt.001    1-channel pulse function arbitrary noise generator
  • Opt.002    2-channel pulse function arbitrary noise generator
  • Opt.1A71 ISO17025 calibration documents
  • Opt.Z54   Z540.3 calibration documents
  • Opt.330   License for 330 Mbit/s pattern generator
  • Opt.660   License for 660 Mbit/s pattern generator
 

More products KEYSIGHT

PXI SWITCH MATRIX 8 X 32 100V/2A AGILENT M9122A

• Connect multiple instruments to multiple points for automated test applications
• 8x32 high-density 1-wire switch matrix
• 100Vrms
• 2A switch/carry current
• 60W max power
• Durable 60W armature switches

 

AGILENT 81160A PULSE FUNCTION ARBITRARY NOISE GENERATOR 500 MHZ

• 1 µHz - 330 MHz pulse generation with variable rise/fall time
• 1 µHz - 500 MHz sine waveform output
• 14-bit, 2.5 GSa/s arbitrary waveforms
• 1 or 2 channel, coupled and uncoupled

 

AGILENT E8257D PSG MICROWAVE ANALOG SIGNAL GENERATOR 250 KHZ..20 GHZ/ 31.8 GHZ/ 40 GHZ/ 50 GHZ/ 67 GHZ

• 250 kHz to 20 GHz, 31.8 GHz, 40 GHz, 50 GHz or 67 GHz operational to 70 GHz
• 0.001 Hz resolution
• +23 dBm @ 20 GHz, +17dBm @ 40 GHz, +14 dBm @ 67 GHz output power (typ); > +30 dBm (typ) with Option 521.
• AM, FM, ØM, pulse, and scan
• Extendable to 75, 90, 110, 140, 170, 220, 325, or 500 GHz

 

AGILENT N9030A PXA SIGNAL SPECTRUM ANALYZER 3 HZ..3.6 / 8.4 / 13.6 / 26.5 GHZ

• 3 Hz to 3.6, 8.4, 13.6, or 26.5 GHz
• 10 MHz (standard), 25, 40, or 140 MHz analysis bandwidth
• Basic EMI precompliance measurement capability available
• Advanced analysis of more than 70 signal formats

 

AGILENT N5182A MXG VECTOR SIGNAL GENERATOR 100 KHZ..3 GHZ/ 6 GHZ

• 100 kHz to 3 GHz or 6 GHz
• 0.01 Hz resolution
• >+23 dBm up to 3 GHz using a highly-reliable, fast-switching electronic attenuator
• 100 MHz internal I/Q baseband generator
• Up to 64 MSa playback memory and 800 MSa storage

 

PXI POWER RELAY SPDT MODULE 20-CHANNELS 250VRMS/5A AGILENT M9135A

• 20-channel SPST switch
• 250Vrms/125Vrms
• 5A switch current and carry current
• 300W max power
• Durable, latching armature relays

 

DIGITAL OSCILLOSCOPE 4 X 500 MHZ AGILENT DSO7054B

• 500 MHz bandwidth
• 4 GSa/s sample rate
• 4 analog channels
• Standard 8 Mpts MegaZoom III deep memory

 

SWITCH MODULE 20 CHANNELS AGILENT 34938A

• 20 Form A channels up to 5A, 150W
• Armature latching relays, with relay counter
• Temperature sensor for overheating conditions

 

DIGITAL OSCILLOSCOPE 2 X 100 MHZ AGILENT DSOX2012A

• 100 MHz bandwidth
• 2 analog channels
• 1GSa/s per channel sample rate

 

AGILENT 53220A RF UNIVERSAL FREQUENCY COUNTER 12 DIGIT 2CH 350 MHZ

• 350 MHz baseband frequency
• 12 digits/sec resolution
• 6 or 15 GHz optional microwave channels
• 100 ps single-shot time resolution