Insulation Tester for Single/Three-Phase Electrical Installations 1000V HT Italia GSC57/ GSC53N/ ZG47
OBSOLET PRODUCT ( * OUT OF USE )

Code: HT Italia GSC57/ GSC53N/ ZG47


 

Datasheet PDF, 0.46 Mb

Description

  • Continuity on protective conductors PE with 200mA
  • Continuity on protective conductors PE with 10A
  • Insulation resistance up to 1000V DC
  • Tripping time and current of RCDs (type A, AC, general and selective)
  • Line and Loop impedance with calculation of the prospective short circuit current
  • Loop/Line impedance with high resolution (0.1mOhm) (with IMP57 optional accessory)
  • Global Earth Resistance without RCDs tripping
  • Earth resistance with 3-wire and 2-wire methods
  • Ground resistivity with 4-wire method
  • Contact voltage
  • Phase rotation
  • TRMS measure and recording of any parameter of Single and Three phase plants
  • Harmonic analysis of voltage and current up to the 49th order
  • Voltage anomalies (sags, swells) with a 10ms resolution
  • Measurement and recording to leakage current (with HT96U optional accessory)
  • Measurement and recording of air temperature  (°C/°F), humidity (HR%)
  • Measurement and recording Illuminations (Lux)
  • Save results inside memory
  • Interface for PC comunication
 

Standard accessories

  • C2033X: cable 3-wire with Shuko plug
  • A0050: power adaptor 230V/50 Hz
  • KITGSC5: kit of 4 cables 2m , 4 alligators e 2 test leads
  • KITTERRNE: bag with 4 cable banana/banana + 4 metal rods
  • Hz
  • TOPVIEW2006: Windows PC software + optical/USB cable C2006
  • BORSA2051: carrying bag
  • Calibration certificate ISO9000
  • User manual
 
GSC57 also include C5700: power cable for 10A continuity test
GSC53N/ ZG47 also include HTFLEX33D: flexible clamp AC 3000A, diameter 174mm, 3 pcs
 

Recommended options

  • C7000/05: 2 cables, 5m length, for 10A test
  • C7000/10: 2 cables, 10m lengt,  for 10A test
  • HT52/05: transducer for air temperature/humidity
  • HT53/05: transducer for lux measurements
  • HTFLEX3003: kit of 3 flexible clamps 300-3000A/1V AC, max diameter 174mm
  • HTFLEX1000: kit of 3 flexible clamp 1000A/1V AC, max diameter 154mm
  • HT96U: clamp 1-100-1000A/1V AC, max diameter 54mm
  • HT97U: clamp 10-100-1000A/1V AC, max diameter 54mm
  • HT903: accessory 3x1-5A/1V for connection to external CT's
  • IMP57: accessory ZLoop/Line at high resolution
 

More products HT ITALIA

ENVIRONEMENTAL MULTIFUNCTION TESTERS HT ITALIA

• Air temperature (°C/°F)
• Air relative humidity (%RH)
• Air speed (m/S)
• Air volume (m3/s)
• Capacity measurements (kW)
• Temperature dew point measurement

 

PV-ISOTEST TESTER FOR CHECKING ELECTRIC SAFETY OF PHOTOVOLTAIC PANELS WITH GROUD FAULT LOCATION GFL FUNCTION

• Insulation measurement up to 1,500V DC even on live systems
• Localization of the faulty module through the new GFL function
• Continuity of the protective conductor with 200mA

 

MULTIFUNCTION PORTABLE MULTIMETER FOR EARTH RESISTANCE MEASUREMENT HT ITALIA M73

• Trip out time measure on AC Standard RCD's
• Trip out current: 30, 30x5, 100, 300mA
• Global Earth Resistance with 0.1Ohm resolution
• Global Earth Resistance without RCD's tripping
• DC Voltage
• AC TRMS Voltage
• Automatic detection of AC/DC signals

 

THT600 INFRARED CAMERA 384X288PXL

• IR Resolution 384x288 pxl
• Temperature range -20° ÷ 650°C
• Image frequency 50Hz
• Thermal sensitivity / NETD <0.05°C @ 30°C / 50mK
• Field of view (FOV) 17° x 12.7°

 

SINGLE/ THREE-PHASE NETWORK AC CURRENT DATA LOGGER HT ITALIA XL421/ XL422

• TRMS AC current measure up to 2500A
• Recording with sampling programmable period
• Manual activation of recording
• RS-232 interface
• Programming with DATALINK software

 

THT80 COMPACT INFRARED THERMOGRAPHY CAMERA 120X90PXL

• IR Resolution 120 x 90 pxl
• Temperature range -20° ÷ 550°C
• Image frequency 50Hz
• Thermal sensitivity / NETD <0.05°C @ 30°C / 50mK
• Field of view (FOV) 50° x 37°

 

DIGITAL PROGRAMMABLE PROFESSIONAL MEGOHMMETER 10TOHM 5KV HT ITALIA HT7051

• Insulation resistance measurement with test voltage up to 5kVDC
• Measurement range up to 10Tohm
• Polarization Index (P.I.) measurement
• Dielectric Absorption Ratio (D.A.R) measurement
• RS-232 interface for PC connection
• Rechargeable internal battery

 

HANDHELD DIGITAL EARTH RESISTANCE METER HT ITALIA GEO416

• 3-wire Earth Resistance
• 2-wire Earth Resistance
• 4-wire Earth Resistivity
• High measurement range (50kOhm)
• Noise voltage measure
• Optical /USB PC interface

 

HT PQA924 CLASS S POWER QUALITY AND ENERGY ANALYZER

• AC voltage in single-phase and three-phase systems
• AC current in single-phase and three-phase systems
• Cosphi, Power Factor, K-Factor
• Voltage unbalance
• Flicker
• Active, Reactive, and Apparent power/energy
• Voltage and current harmonic amplitude and phase up to the 63rd order with THD% calculation

 

AUDIO ANALYZER CLASS 1 HT ITALIA HT155/ HT157

• Measuring range 25-140dB
• "Peak", "Fast", "Slow" and "Impulse" integrations
• "A", "C" and "Z (linear)" frequency weighting
• "Peak+" and "Peak-" measurement in C weighting
• Spectral analysis with octave and 1/3 octave digital filter (HT157)
• Class 1 portable calibrator
• Mini-USB output for connection to PC