RTD Temperature Calibrator Fluke 712

Code: Fluke 712


 

Datasheet PDF, 0.11 Mb

Description

  • -200 to 800ºC Range Measure / simulate RTD (Pt 100)
  • 0 to 3200 O Range Measure / simulate resistance
  • 0.1 O, 0.1 ºC Resolution
  • 0.025% Accuracy
  • Measure temperature from RTD output
  • Simulate RTD output
  • Operates with seven types of RTDs
  • Measure additional RTDs using Ohms measurement function
  • Simulate additional RTDs using Ohms source function
  • ºF or ºC selectable
  • Four shrouded banana jacks
  • Compatible with Rosemount® pulsed RTD transmitters (pulses > 10ms)
  • Holster features test lead storage
  • Compatible with toolpack magnetic hanging system
 

Standard accessories

  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • single 9V alkaline battery
  • Test Leads and Alligator Clips
  • NIST-traceable calibration report and data
 

More products FLUKE

HANDHELD LOOP CALIBRATOR FLUKE 707

• 0 to 28 V DC Voltage measure
• 0 to 24 mA Current measure
• 0 to 20 mA Current source / simulate
• mA accuracy of 0.015%

 

FLUKE VT02 INFRARED THERMOMETER WITH INTEGRATED CAMERA

• take simultaneous visual images with the thermal heat map images that are accurately aligned close in
• Temperature measurement range -10 °C to +250 °C (14 °F to 482 °F)
• Infrared spectral band 6.5 µm to 14 µm
• Minimum focus distance 50 cm (19.6 in)
• Field of View 20° X 20°
• 4 GB Micro SD card

 

FLUKE 190-504 190-504/S HANDHELD SCOPEMETER OSCILLOSCOPE 4X500 MHZ

• 4-channels isolated 500MHz
• CAT III 1000V / CAT IV 600V safety rated
• Dedicated 5000 Count digital multimeter in two-channel models
• Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
• IP-51 rated for dust and drip proof to withstand harsh environments
• Isolated USB ports for memory devices and PC connectivity

 

CURRENT CLAMP METER 400 A FLUKE 322

• Measures AC current to 400 A with 0.1 A resolution
• Measures AC current to 40 A with 0.01 A resolution, precise low current measurements
• Measures AC volts to 600 V, with 0.1 V resolution to 400.0 V
• Measures DC volts to 600 V, with 0.1 resolution to 400.0 V
• Resistance measurement to 400 O
• Precise measurements with 1.8% basic accuracy

 

VOLTAGE DETECTOR FLUKE 1AC II VOLTALERT

• CAT IV 1000 V for added protection
• 200 V to 1000 V AC

 

FLUKE MEMOBOX 1744 THREE PHASE POWER QUALITY LOGGER

• monitor & logging: V, A, W, VA, VAR, PF, energy, flicker, voltage events, and THD
• measures voltage & current harmonics, interharmonics, mains signaling, unbalance, frequency
• Plug and play
• Determines the root cause
• Monitors power for the long-term
• 0.1% voltage accuracy IEC61000-4-30 Class-A compliant
• IP65 water-proof

 

FLUKE 700LTP-1 LOW-PRESSURE VACUUM TEST PUMP

• hand operated pressure pump
• designed to generate either vacuum to -13 psi / -.90 bar or pressures to 100 psi / 6.9 bar
• Pump can be easily cleaned without disassembly
• Adjustable pressure relief valve with slow-bleed capability. Allows the slow release pressure at a controlled rate
• Quick fit connectors, one for the reference port for connection to a Fluke 700 series pressure module and one to connect to a unit under test
• Slim design, easy to carry and use

 

MILIAMP PROCESS CLAMP METER FLUKE 773

• 0 to 24 mA Current measure / source / simulate
• Best in class 0.2 % accuracy
• 0.01 mA resolution and sensitivity
• 0 to 30 V DC Voltage measure
• 0 to 10 V DC Voltage source

 

DIGITAL PYROMETER FLUKE 63

• Single point offset laser sighting
• Best accuracy in its class: + 1% of reading
• Holds temperature readings for 7 seconds
• Dual displays shows current and MAX measurements simultaneously
• Backlit display for poorly lit areas
• Wide temperature range from -30º to 500ºC (-20º to 932ºF)

 

LASER DISTANCE METER 80M FLUKE 419D

• Instantly measures up to 80m (260 ft) with accuracy of +/- 1mm
• 3-line display plus storage for 20 complete displays
• Tripod mountable