RTD Temperature Calibrator Fluke 712

Code: Fluke 712


 

Datasheet PDF, 0.11 Mb

Description

  • -200 to 800ºC Range Measure / simulate RTD (Pt 100)
  • 0 to 3200 O Range Measure / simulate resistance
  • 0.1 O, 0.1 ºC Resolution
  • 0.025% Accuracy
  • Measure temperature from RTD output
  • Simulate RTD output
  • Operates with seven types of RTDs
  • Measure additional RTDs using Ohms measurement function
  • Simulate additional RTDs using Ohms source function
  • ºF or ºC selectable
  • Four shrouded banana jacks
  • Compatible with Rosemount® pulsed RTD transmitters (pulses > 10ms)
  • Holster features test lead storage
  • Compatible with toolpack magnetic hanging system
 

Standard accessories

  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • single 9V alkaline battery
  • Test Leads and Alligator Clips
  • NIST-traceable calibration report and data
 

More products FLUKE

FLUKE 8846A DIGITAL BENCH MULTIMETER 6.5 DIGIT

• 6.5 digit resolution
• Basic Vdc accuracy 0.0024 %
• Dual display
• 100 µA to 10 A current range, with up to 100 pA resolution

 

CURRENT CLAMP METER 400 A FLUKE 322

• Measures AC current to 400 A with 0.1 A resolution
• Measures AC current to 40 A with 0.01 A resolution, precise low current measurements
• Measures AC volts to 600 V, with 0.1 V resolution to 400.0 V
• Measures DC volts to 600 V, with 0.1 resolution to 400.0 V
• Resistance measurement to 400 O
• Precise measurements with 1.8% basic accuracy

 

PROCESS MULTIMETER FLUKE 789

• 0 to 1000 V DC/AC Voltage measure
• 0 to 1 A Current measure
• 0 to 20 mA, 4 to 24 mA Current source
• DMM and loop calibrator in one tool
• HART mode setting with loop power

 

FLUKE 700G/TRACK DATALOGGING SOFTWARE FOR 700G PRESSURE GAUGES

• Precision pressure measurement from -20 mbar to 690 bar
• Absolute pressure measurement ranges 15, 30, 100, 300 psia
• Accuracy to 0.05 % of full scale
• Reference class gauge accuracies to 0.04 % of reading
• Easy to use, rugged construction for reliable performance

 

FLUKE 719PRO ELECTRIC PRESSURE CALIBRATOR

• Fluke-719Pro-30G -12 to 30 PSI / -0.8 to 2 bar
• Fluke-719Pro-150G -12 to 150 PSI / -0.8 to 10 bar
• Fluke-719Pro-300G -12 to 300 PSI / -0.8 to 20 bar
• Unique integrated electric pump for one handed pressure calibration
• Pressure measurement from internal or external sensor
• Sourced/simulated or measured mA values
• Temperature measured by optional RTD probe

 

FLUKE II915 ACUSTIC CAMERA FOR GAS LEAKS, ELECTRICAL DISCHARGES, AND MECHANICAL FAULTS

• Enhanced Performance: Improved detection performance for gas leaks, electrical discharges, and mechanical issues.
• LeakQâ„¢ Mode: Estimated leak size and cost.
• PDQ Modeâ„¢: Assesses discharge severity.
• MecQâ„¢ Mode: Proactively address potential problems in rotating mechanical components.
• Reporting Features: Integrated visual and textual tagging and annotation functionalities for streamlined reporting.
• Wireless Upload: Easily transfer data to Fluke Connect.

 

LASER DISTANCE METER 60M FLUKE 416D

• Ability to measure up to 60 m (200 ft) with increased accuracy of up to 1.5 mm (0.06 in)
• Measurement to 30 m (100 ft) with accuracy of 3 mm (0.12 in)
• Instant measurement with one-button operation.
• Easy targeting with bright laser.
• Quick calculation of area and volume.
• Easy addition and subtraction of measurements.

 

HANDHELD LOOP CALIBRATOR FLUKE 707

• 0 to 28 V DC Voltage measure
• 0 to 24 mA Current measure
• 0 to 20 mA Current source / simulate
• mA accuracy of 0.015%

 

VIBRATION METER FLUKE 805

• measures overall vibration as well as specific variables like bearing condition and temperature
• calculate bearing condition and overall vibration
• Sensor sensitivity can read a wide range of frequencies (10 to 1,000 Hz and 4,000 to 20,000 Hz)
• Exportable data via USB
• Crest Factor+

 

FLUKE TI300 INFRARED CAMERA 240X180 RESOLUTION

• 240x180 Detector resolution
• Ruggedized high resolution 640x480 capacitive touch screen for quick menu navigation
• Range: -20 °C si +650 °C
• Precision : ± 2 °C sau 2%
• Sensibility : = 0,05 °C