RTD Temperature Calibrator Fluke 712

Code: Fluke 712


 

Datasheet PDF, 0.11 Mb

Description

  • -200 to 800ºC Range Measure / simulate RTD (Pt 100)
  • 0 to 3200 O Range Measure / simulate resistance
  • 0.1 O, 0.1 ºC Resolution
  • 0.025% Accuracy
  • Measure temperature from RTD output
  • Simulate RTD output
  • Operates with seven types of RTDs
  • Measure additional RTDs using Ohms measurement function
  • Simulate additional RTDs using Ohms source function
  • ºF or ºC selectable
  • Four shrouded banana jacks
  • Compatible with Rosemount® pulsed RTD transmitters (pulses > 10ms)
  • Holster features test lead storage
  • Compatible with toolpack magnetic hanging system
 

Standard accessories

  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • single 9V alkaline battery
  • Test Leads and Alligator Clips
  • NIST-traceable calibration report and data
 

More products FLUKE

FLUKE 719PRO ELECTRIC PRESSURE CALIBRATOR

• Fluke-719Pro-30G -12 to 30 PSI / -0.8 to 2 bar
• Fluke-719Pro-150G -12 to 150 PSI / -0.8 to 10 bar
• Fluke-719Pro-300G -12 to 300 PSI / -0.8 to 20 bar
• Unique integrated electric pump for one handed pressure calibration
• Pressure measurement from internal or external sensor
• Sourced/simulated or measured mA values
• Temperature measured by optional RTD probe

 

FLUKE 1750 THREE PHASE POWER LOGGER

• Power quality that meets the standard: comply with IEC61000-4-30 standards for voltage, current, power, harmonics, flicker etc.
• 5 MHz, 8000 Vpk waveform capture: Get a detailed picture of even the shortest events
• 5 MHz Transient Voltage
• Captures everything
• Plug and play
• Wireless connection

 

FLUKE 1577 MEGOHMMETER INSULATION MULTIMETER 500/ 1000V

• Insulation test: 0.1 MO to 600 MO
• Insulation test voltages: 500 V, 1000 V

 

FLUKE 438 II MOTOR AND ENERGY QUALITY ANALYZER

• Measure key parameters on direct-on-line motors including torque, RPM, mechanical power and motor efficiency
• Perform dynamic motor analysis by plotting of motor derating factor against load according to NEMA/IEC guidelines
• Calculate mechanical power and efficiency without the need of mechanical sensors, just connect to the input conductors and you're ready to go
• Measure electrical power parameters such as voltage, current, power, apparent power, power factor, harmonic distortion and unbalance to identify characteristics that impact motor efficiency

 

HANDHELD LOOP CALIBRATOR FLUKE 707

• 0 to 28 V DC Voltage measure
• 0 to 24 mA Current measure
• 0 to 20 mA Current source / simulate
• mA accuracy of 0.015%

 

MULTI-PRODUCT CALIBRATOR FLUKE 5500E

• Handheld digital multimeters
• Bench multimeters (up to 4½ digits)
• Clamp meters
• Electronic thermometers
• Oscilloscope recorders

 

INDUSTRIAL VOLTAGE AND CURRENT MEASUREMENT SYSTEM FLUKE CNX 3000 IND

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• True-RMS AC current measurements to 2500 A
• True-RMS AC voltage measurements to 1000V
• CAT III 1000 V, CAT IV 600 V, CAT III 1000 V; IP42


INDUSTRIAL MEASUREMENT SYSTEM FLUKE CNX 3000 HVAC

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• Temperature measurements from -200 °C to 1372 °C
• True-RMA AC current measurements to 400 A


INFRARED NON-CONTACT THERMOMETER FLUKE 61

• Bright laser beam provides easy targeting
• Display clearly supplies data at a glance
• Shock-absorbing holster increases ruggedness
• 0.2 °C (0. 5 °F) resolution up to 275 °C (525 °F)
• Backlight illuminates the screen in the dark
• Automatic sleep mode after 7 seconds extends battery life
• Alkaline batteries provide 4000 typical measurements

 

PHASE ROTATION INDICATOR FLUKE 9040

• 3 phase indication
• Indication of phase rotation
• Clear LCD display
• No battery required