RTD Temperature Calibrator Fluke 712

Code: Fluke 712


 

Datasheet PDF, 0.11 Mb

Description

  • -200 to 800ºC Range Measure / simulate RTD (Pt 100)
  • 0 to 3200 O Range Measure / simulate resistance
  • 0.1 O, 0.1 ºC Resolution
  • 0.025% Accuracy
  • Measure temperature from RTD output
  • Simulate RTD output
  • Operates with seven types of RTDs
  • Measure additional RTDs using Ohms measurement function
  • Simulate additional RTDs using Ohms source function
  • ºF or ºC selectable
  • Four shrouded banana jacks
  • Compatible with Rosemount® pulsed RTD transmitters (pulses > 10ms)
  • Holster features test lead storage
  • Compatible with toolpack magnetic hanging system
 

Standard accessories

  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • single 9V alkaline battery
  • Test Leads and Alligator Clips
  • NIST-traceable calibration report and data
 

More products FLUKE

POWER QUALITY CLAMP METER FLUKE 345

• 2000A AC/DC current
• 600 V CAT IV power analyzer
• Data logging
• Troubleshoot harmonics
• Inrush current

 

TEMPERATURE AND HUMIDITY METER FLUKE 971

• Temperature range from -20 °C to 60 °C (-4°F to 140 °F)
• Relative humidity from 5 % to 95 %
• Min/Max/Avg Data hold
• Low battery indicator

 

DOCUMENTING PROCESS CALIBRATOR FLUKE 741B

• 0 to 300 V DC/AC Voltage measure
• 0 to 15 V DC Voltage source / simulate
• 0 to 110 mA DC Current measure
• 0 to 22 mA DC Current source / simulate
• 0 to 11 kO Resistance measure / source / simulate
• 1 to 50 kHz Frequency measure / source / simulate

 

FLUKE MEMOBOX 1744 THREE PHASE POWER QUALITY LOGGER

• monitor & logging: V, A, W, VA, VAR, PF, energy, flicker, voltage events, and THD
• measures voltage & current harmonics, interharmonics, mains signaling, unbalance, frequency
• Plug and play
• Determines the root cause
• Monitors power for the long-term
• 0.1% voltage accuracy IEC61000-4-30 Class-A compliant
• IP65 water-proof

 

FLUKE VT04 INFRARED THERMOMETER WITH INTEGRATED CAMERA

• take simultaneous visual images with the thermal heat map images that are accurately aligned close in
• Temperature measurement range -10 °C to +250 °C (14 °F to 482 °F)
• Infrared spectral band 6.5 µm to 14 µm
• Minimum focus distance 50 cm (19.6 in)
• Field of View 28° X 28°
• 4 GB Micro SD card

 

HANDHELD LOOP CALIBRATOR FLUKE 707

• 0 to 28 V DC Voltage measure
• 0 to 24 mA Current measure
• 0 to 20 mA Current source / simulate
• mA accuracy of 0.015%

 

FLUKE 700LTP-1 LOW-PRESSURE VACUUM TEST PUMP

• hand operated pressure pump
• designed to generate either vacuum to -13 psi / -.90 bar or pressures to 100 psi / 6.9 bar
• Pump can be easily cleaned without disassembly
• Adjustable pressure relief valve with slow-bleed capability. Allows the slow release pressure at a controlled rate
• Quick fit connectors, one for the reference port for connection to a Fluke 700 series pressure module and one to connect to a unit under test
• Slim design, easy to carry and use

 

FLUKE 1735 THREE PHASE POWER LOGGER

• Record power and associated parameters for up to 45 days
• Measure harmonic distortion caused by electronic loads
• Voltage event capture
• View graphs and generate reports

 

FLUKE 190-204 190-204/S HANDHELD SCOPEMETER OSCILLOSCOPE 4X200 MHZ

• 4-channels isolated 200MHz
• CAT III 1000V / CAT IV 600V safety rated
• Dedicated 5000 Count digital multimeter in two-channel models
• Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
• IP-51 rated for dust and drip proof to withstand harsh environments
• Isolated USB ports for memory devices and PC connectivity

 

LASER DISTANCE METER 80M FLUKE 419D

• Instantly measures up to 80m (260 ft) with accuracy of +/- 1mm
• 3-line display plus storage for 20 complete displays
• Tripod mountable