  • -200 to 800ºC Range Measure / simulate RTD (Pt 100)
  • 0 to 3200 O Range Measure / simulate resistance
  • 0.1 O, 0.1 ºC Resolution
  • 0.025% Accuracy
  • Measure temperature from RTD output
  • Simulate RTD output
  • Operates with seven types of RTDs
  • Measure additional RTDs using Ohms measurement function
  • Simulate additional RTDs using Ohms source function
  • ºF or ºC selectable
  • Four shrouded banana jacks
  • Compatible with Rosemount® pulsed RTD transmitters (pulses > 10ms)
  • Holster features test lead storage
  • Compatible with toolpack magnetic hanging system
 

Standard accessories

  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • single 9V alkaline battery
  • Test Leads and Alligator Clips
  • NIST-traceable calibration report and data
 

More products FLUKE

FLUKE ESA712 ELECTRO-SECURITY ANALYZER FOR MEDICAL EQUIPMENTS

• 5†Touchscreen with intuitive user interface
• Small, portable, ergonomic design with an integratedhandle
• Ten applied parts posts with innovative LED lighting guidance (ECG & Banana)
• Insulation resistance from 50V, 100V, 250V and 500V

 

FLUKE II915 ACUSTIC CAMERA FOR GAS LEAKS, ELECTRICAL DISCHARGES, AND MECHANICAL FAULTS

• Enhanced Performance: Improved detection performance for gas leaks, electrical discharges, and mechanical issues.
• LeakQâ„¢ Mode: Estimated leak size and cost.
• PDQ Modeâ„¢: Assesses discharge severity.
• MecQâ„¢ Mode: Proactively address potential problems in rotating mechanical components.
• Reporting Features: Integrated visual and textual tagging and annotation functionalities for streamlined reporting.
• Wireless Upload: Easily transfer data to Fluke Connect.

 

FLUKE VT02 INFRARED THERMOMETER WITH INTEGRATED CAMERA

• take simultaneous visual images with the thermal heat map images that are accurately aligned close in
• Temperature measurement range -10 °C to +250 °C (14 °F to 482 °F)
• Infrared spectral band 6.5 µm to 14 µm
• Minimum focus distance 50 cm (19.6 in)
• Field of View 20° X 20°
• 4 GB Micro SD card

 

INTRINSICALLY SAFE CALIBRATOR FLUKE 725EX

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 10 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 3200 O Resistance measure / source / simulate
• 1 to 10 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure
• ATEX II 1 G Ex ia IIB 171°C KEMA 04ATEX 1303X

 

FLUKE 77IV HANDHELD DIGITAL MULTIMETER 3.5 DIGIT

• 3.5 digit
• 6000 count resolution
• 0.3% basic accuracy
• Large display
• Backlight for work in dim areas

 

DIGITAL CONTACT THERMOMETERS SERIES FLUKE 50 II

• Relative time clock on MIN, MAX, and AVG provides a time reference for major events
• Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
• Measures J, K, T, and E-types of thermocouples
• Readout in ºC, ºF, or Kelvin (K)
• Data Logging up to 500 points of data with user adjustable recording interval(Fluke 53 II and Fluke 54 II)

 

FLUKE 700HTPK HYDRAULICTEST KIT FOR PRESSURE CALIBRATION

• Combine with any Fluke-700G Series Gauge, 1,000 psi range or greater, to make a complete pressure testing kit
• Generates pressure up to 10,000 psi range or greater, to make a complete pressure testing kit
• Connect the 700G Series gauge directly to the HTP-2 hand pump
• Includes 700HTH-1 hose kit and adapters for connecting to the pressure device to be tested
• Hard case protects pump and gauge and allows gauge to remain connected to the pump

 

FLUKE 700PTPK PNEUMATIC TEST KIT FOR PRESSURE CALIBRATION

• Combine with any Fluke-700G Series Gauge, 1,000 psi (69 bar) or less, to make a complete pressure testing kit
• Generate pressure up to 600 psi, 40 bar with the 700PTP-1 test pump
• Connect the 700G Series gauge directly to the included PTP-1 hand pump
• Includes hoses and adapters for connecting to the pressure device to be tested
• Hard case protects pump and gauge and allows gauge to remain connected to the pump

 

FLUKE 8845A DIGITAL BENCH MULTIMETER 6.5 DIGIT

• 6.5 digit resolution
• Basic Vdc accuracy 0.0035 %
• Dual display
• 100 µA to 10 A current range, with up to 100 pA resolution

 

FLUKE TIS45 INFRARED CAMERA 160X120

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels