Fluke 1577 Megohmmeter Insulation Multimeter 500/ 1000V

Code: Fluke 1577


 

Datasheet PDF, 0.15 Mb

Description

  • Insulation test: 0.1 MO to 600 MO
  • Insulation test voltages: 500 V, 1000 V
  • Large display with backlight
  • Live circuit detection prevents insulation test if voltage >30 V is detected
  • Auto-discharge of capacitive voltage
  • AC/DC voltage, DC milliVolts, AC/DC milliamps, Resistance, Continuity
  • Auto power off to save battery power
  • CAT III 1000 V, CAT IV 600 V measurement category
 

Standard accessories

  • Remote probe
  • Test leads
  • Alligator clips
  • Hard case
  • Four AA alkaline batteries
  • Quick Reference Guide
  • CD Rom with Manual
 

Recommended options

  • TLK225  SureGrip™ Master Accessory Kit
  • TL27  Heavy Duty Test Lead Set
  • AC285 SureGrip™ Alligator Clip Set
  • TL225 Stray Voltage Adapter Test Lead Kit
  • TP220 SureGrip™ Industrial Test Probes
 

More products FLUKE

FLUKE 438 II MOTOR AND ENERGY QUALITY ANALYZER

• Measure key parameters on direct-on-line motors including torque, RPM, mechanical power and motor efficiency
• Perform dynamic motor analysis by plotting of motor derating factor against load according to NEMA/IEC guidelines
• Calculate mechanical power and efficiency without the need of mechanical sensors, just connect to the input conductors and you're ready to go
• Measure electrical power parameters such as voltage, current, power, apparent power, power factor, harmonic distortion and unbalance to identify characteristics that impact motor efficiency

 

FLUKE 1625-2 GEO EARTH GROUND RESISTANCE TESTER

• 3- and 4-pole Fall-of-Potential, earth resistance loop testing
• 4-pole Soil Resistivity testing
• Selective earth ground rod testing using 1 clamp
• Stakeless earth ground rod testing using 2 clamps
• IP56 rated for outdoor use
• USB data storage and transfer
• Automatic Frequency Control (AFC)
• R* measurement - calculates earth ground impedance at 55 Hz

 

LASER DISTANCE METER 30M FLUKE 411D

• Measurement to 30 m (100 ft) with accuracy of 3 mm (0.12 in)
• Instant measurement with one-button operation.
• Easy targeting with bright laser.
• Quick calculation of area and volume.
• Easy addition and subtraction of measurements.
• Designed for indoor and outdoor use.

 

INFRARED NON-CONTACT THERMOMETER FLUKE 62 MAX

• Dust and water-resistant: IP54 rated for dust and water resistance.
• Rugged: 3-meter (9.8-foot) drop tested.
• Ergonomically designed: Completely redesigned for a more natural hand fit.
• Large, backlit display: Large screen makes data easier to read, even in dark areas.
• Min/Max/Avg/Dif: Displays the minimum, maximum or average temperature, or the difference between two measurements.
• Alarm: Hi and Lo alarms for rapid display of measurements outside the limits

 

WIRELESS CURRENT CLAMP FLUKE CNX A3000

• True-RMS AC current measurements to 400 A
• 2% accuracy to 100 Hz, 2-1/2% accuracy to 500 Hz
• Memory recording up to 65,000 readings
• Backlit LCD display
• CAT III 600 V; IP42


HANDHELD LOOP CALIBRATOR FLUKE 705

• 0 to 28 V DC Voltage measure
• 0 to 24 mA Current measure
• 0 to 20 mA Current source / simulate
• mA accuracy of 0.02%

 

PROCESS MULTIMETER FLUKE 789

• 0 to 1000 V DC/AC Voltage measure
• 0 to 1 A Current measure
• 0 to 20 mA, 4 to 24 mA Current source
• DMM and loop calibrator in one tool
• HART mode setting with loop power

 

FLUKE 1587 MEGOHMMETER INSULATION MULTIMETER 50/ 1000V

• Insulation test: 0.01 MO to 2 GO
• Insulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V

 

FLUKE TIS45 INFRARED CAMERA 160X120

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

FLUKE 721 PRESSURE CALIBRATOR

• 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor
• 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
• Ideal for gas flow calibration (custody transfer) applications
• Two isolated, stainless steel, pressure sensors with 0.025 % accuracy
• Pt100 RTD input for temperature measurement, (probe optional)
• Measures 4 to 20 mA signals
• Internal 24 V loop power supply can power a transmitter under test
• Measure up to 30 V dc, check 24 V loop power supplies