Brand: FLUKE BIOMEDICAL

Incubator Analyzer Fluke Biomedical INCU

Code: Fluke Biomedical INCU


 

Datasheet PDF, 0.16 Mb

Description

The INCU™ is an incubator analyzer, designed around AAMI and IEC standards, that specifies temperature, humidity, sound and airflow characteristics of incubators.

 

 

  • Portability (sitting in place of infant within incubator)
  • Single-instrument measurement and documentation for key infant-incubator parameters
  • Measurement for most parameters according to IEC and AAMI standards
  • Time-saving in testing critical infant incubators
  • Windows® software for evaluation and documentation
  • Numerical and graphical reports
  • Adjustable measurement intervals
  • Standalone, or full function (computer required)
 

Standard accessories

  • User manual (3901000)
  • Soft-sided carrying case (97156)
  • Airflow sensor (76060)
  • Universal AC battery charger with worldwide mains adapter set (48583FG)
  • Serial cable DB9F to DB9F(with serial adapter DB9M to DB9M) (75101FG)
  • Outside temperature probe holder (48582)
  • Adapter for radiant infant warmer assembly (76058)
  • INCU PC software (one CD) (48581)
 

More products FLUKE

ELECTRICAL SAFETY ANALYZER FOR MEDICAL ROOMS FLUKE BIOMEDICAL ESA620

• Compliance with multiple standards
• Three test loads
• Expanded leakage ranges through 10,000 µA
• AC only, DC only and True RMS leakage readings
• 100 % and 110 % mains voltage for mains on applied part (lead isolation) test
• 20 A equipment current

 

ELECTROSURGERY ANALYZER FLUKE BIOMEDICAL RS303 RS

• New Signal Averaging Mode (SAMTM)
• New RS232 port
• Battery powered for completely isolated measurement
• Digital display
• HF-leakage-current measurement
• 4-digit numeric LCD with backlight and power-save mode

 

ELECTROSURGERY ANALYZER FLUKE BIOMEDICAL QA-ES

• Automatic power distribution measurement, including power, current, peak-to-peak voltage closed load only), and crest factor
• High-frequency leakage measurements with accuracy of ± 2 % of reading
• 128 internal user-selectable test loads from 10 O to 5200 O
• Ansur QA-ES software plug-in for automated test protocols
• RS-232 and Centronic-printer interface

 

DIGITAL ELECTRICAL SAFETY TESTER FLUKE BIOMEDICAL LT544

• Small, lightweight, self-contained portable instrument
• Universal Power Supply. Input voltage from 85 - 265 VAC
• Chassis Resistance measurements are made with a four-wire Kelvin bridge to eliminate errors due to cable length
• Test method complies with AAMI load per ANSI/AAMI ES1-1993


PHOTOTHERAPY RADIOMETER LIGHT RADIATION MEASURING FLUKE BIOMEDICAL DALE40

• Large LCD
• Accurate to ±5% of full scale
• Spectral range of 429-473 nm
• Complete portability


ELECTRICAL SAFETY ANALYZER FLUKE BIOMEDICAL 601 PRO

• EN60601-1, EN601010-1, and AAMI test loads (user selectable)
• Multiple enclosure-leakage points
• Multiple patient-applied-part types
• Power ON/OFF delay
• DC only for patient- and auxiliary-leakage tests
• User-programmable test sequences

 

PRESSURIZED ION CHAMBER SURVEY METER FOR GAMMA, X-RAY RADIATION FLUKE BIOMEDICAL 451P

• High sensitivity µR measurements of rate and dose simultaneously, with the capability to record peak rate
• Ergonomic, anti-fatigue handle with replaceable grip, wrist strap and tripod mount
• Programmable flashing LCD display and audible alarm
• Easily-accessible battery door (operated by two 9-volt alkaline batteries) on the outside of the bottom case

 

ELECTRICAL SAFETY ANALYZER FLUKE BIOMEDICAL DALE 601E

• Small, lightweight, self-contained portable instrument
• Master range meter delivers accurate measurment for each test
• Accurate test measurements with 4-wire Kelvin bridge
• Test method complies with AAMI load per ANSI/AAMI ES1-1993 or IEC601-1
• Leakage Current can be measured in Open/Closed Neutral, Normal/Reversed Polarity and Open/Closed Ground
• All Leakage Current measurements are displayed directly in µAmps
• Broad range of external measurements
• Five (5) Universal EKG Lead Connectors
• The DALE601E is designed for 230 V operation


LIM/ GFI ISOLATION CURRENTS TESTER FLUKE BIOMEDICAL DALE2000

• Unique digital circuitry retains measurement
• Direct reading of Line Voltage, LIM and GFI current
• 9 volt battery operation
• Universal voltages from 85 to 245 VAC, 50/60 Hz
• Small, lightweight, very portable


LUNG PRECISION TEST SINULATOR FLUKE BIOMEDICAL ACCU LUNG

• Small, lightweight and portable
• User-selectable compliance and resistance settings
• Calibrated accuracy for both resistance and compliance
• Complies with IEC standard for breathing- circuit connection
• Certified test lung for test system traceability to standards