Brand: FLUKE BIOMEDICAL

Rigid Endoscope Tester Fluke Biomedical DALE301

Code: Fluke Biomedical DALE301


 

Description

A simple-to-use, quick check for rigid endoscopes.

Finally, there is a simple tool for technical and non-technical personnel to perform a quick evaluation of most rigid endoscopes. With the DALE301, your staff diagnoses problems during incoming inspections, after complaints, pre- and post-service, and as a routine preventive-maintenance inspection.

With the DALE301, you can identify the following:

 

  • Broken lenses
  • Crooked rod shaft
  • Normal wear and tear
  • Internal moisture
  • Presence of contamination
  • Lens debris

 

Features

  • Incoming acceptance inspection performed
  • Simple to use
  • Lightweight and companct
  • No light source or other accessories required
  • Pre-repair inspections to prevent unneeded repairs and save money
  • Post-repair inspections to verify a performed service or indicate if a repair was simply a "dusting-off"
  • Compatible with most rigid endoscopes
  • Compatible with common cameras for hard copy documentation to trend test or to compare and decument service

 

 

Specifications

Outer Diameter of Eyepiece

 

 31.75 mm +0 -0.1 per DIN 58105

End-Cap Inner Diameter

 

 No less then 120 mm

Optical Design

Focal length:

 40 mm ± 3%

Refraction:

 25 dpt

Material:

 PMMA (Plexiglass)

Diameter:

 19 mm

Focal Point Adjustment Scale

 

 16 cm

Maximum Diameter of Rigid Endoscope

 

 <10 mm

Environmental

Operating Temperature:

 15 to 40 °C

Storage Temperature:

 -10 to +65 °C

Relative Humidity:

 95% max

Dimensions

 

 8.75" L x 1.75" W x 1.75" H

 

 (22 cm L x 4 cm W x 4 cm H)

Weight

 

 13.1 oz ( 370 g)

 

More products FLUKE BIOMEDICAL

OXIGEN O2 CONCENTRATION ANALYZER FLUKE BIOMEDICAL MAXO2 PLUS AE

• One-touch calibration, with reminder
• Long battery life (approx. 5,000 hrs)
• Impact resistant and drip proof
• External MAX-250E Oxygen Sensor

 

ELECTRICAL SAFETY ANALYZER FLUKE BIOMEDICAL 601 PRO

• EN60601-1, EN601010-1, and AAMI test loads (user selectable)
• Multiple enclosure-leakage points
• Multiple patient-applied-part types
• Power ON/OFF delay
• DC only for patient- and auxiliary-leakage tests
• User-programmable test sequences

 

ELECTROSURGERY ANALYZER FLUKE BIOMEDICAL RS303 RS

• New Signal Averaging Mode (SAMTM)
• New RS232 port
• Battery powered for completely isolated measurement
• Digital display
• HF-leakage-current measurement
• 4-digit numeric LCD with backlight and power-save mode

 

PNEUMATIC TRANSDUCER PRESSURE GENERATING/ MEASURING FLUKE BIOMEDICAL DPM1B

• Battery operated
• Generates and measures positive or negative pressures
• Operates with gas and liquid
• Troubleshooting with 1 % accuracy

 

ULTRASOUND ELECTRICAL SAFETY TRANSDUCER LEAKAGE CURRENT TESTER FLUKE BIOMEDICAL ULT800

• Handheld
• Stand-alone operation
• Direct measurement of leakage current
• Battery-operated
• Independent of 120 V or 240 V systems
• Built-in self-test circuit
• Auto shut-off to conserve battery

 

DEFIBRILLATOR PULSE EXTERNAL PACER ANALYZER FLUKE BIOMEDICAL 6000D/ 7000DP

• Lown, Edmark, trapezoidal, biphasic and pulsed-biphasic defibrillation technology compatibility
• AED technology compatibility
• First-class measurement accuracy ± 1 % of reading + 0.1 J
• Intuitive user interface and backlight, easy-to-read display
• Portable, rugged, easy to carry

 

GAS/ LIQUID PRESSURE TESTER OF MEDICAL EQUIPMENTS FLUKE BIOMEDICAL DPM2PLUS

• Handheld
• Battery operated
• 1 % accuracy
• Five selectable scale ranges
• Voltage output to drive a recorder for assessing electronics of pressure measurement circuit
• Air or liquid measurement


DIGITAL ELECTRICAL SAFETY TESTER FLUKE BIOMEDICAL LT544

• Small, lightweight, self-contained portable instrument
• Universal Power Supply. Input voltage from 85 - 265 VAC
• Chassis Resistance measurements are made with a four-wire Kelvin bridge to eliminate errors due to cable length
• Test method complies with AAMI load per ANSI/AAMI ES1-1993


LUNG PRECISION TEST SINULATOR FLUKE BIOMEDICAL ACCU LUNG

• Small, lightweight and portable
• User-selectable compliance and resistance settings
• Calibrated accuracy for both resistance and compliance
• Complies with IEC standard for breathing- circuit connection
• Certified test lung for test system traceability to standards

 

UNIVERSAL DIGITAL RADIATION MONITORING RATEMEMTER FLUKE BIOMEDICAL 942A/ 946A/ 952A

• User adjustable alarm set-points; retained indefinitely on power outage, keylock protection available
• Front panel pushbuttons for check source activation, high voltage indication, alarm setpoint indication, alarm acknowledge, and power ON/OFF
• Small front panel size allows dedicated display for each channel while minimizing panel space
• Ability to use existing cables when replacing most analog readouts