Current Clamp Meter 400 A Fluke 322

Code: Fluke 322


 

Datasheet PDF, 0.53 Mb

Description

  • Measures AC current to 400 A with 0.1 A resolution
  • Measures AC current to 40 A with 0.01 A resolution, precise low current measurements
  • Measures AC volts to 600 V, with 0.1 V resolution to 400.0 V
  • Measures DC volts to 600 V, with 0.1 resolution to 400.0 V
  • Resistance measurement to 400 O
  • Precise measurements with 1.8% basic accuracy
  • New smaller size fits easily into tight places
  • Continuity for quick checking of shorts
  • Automatic low battery indicator
  • Display hold function
  • All inputs are protected to EN61010-1, 600 V CAT III, UL, CSA and TüV listed
  • Two year warranty
 

Standard accessories

  • (2) AAA Alkaline batteries
  • Instruction card
  • Safety information sheet
  • Soft carrying case
  • Test leads
 

Recommended options

  • TL223   SureGrip™ Electrical Test Lead Kit
 

More products FLUKE

FLUKE 8845A DIGITAL BENCH MULTIMETER 6.5 DIGIT

• 6.5 digit resolution
• Basic Vdc accuracy 0.0035 %
• Dual display
• 100 µA to 10 A current range, with up to 100 pA resolution

 

FLUKE 719PRO ELECTRIC PRESSURE CALIBRATOR

• Fluke-719Pro-30G -12 to 30 PSI / -0.8 to 2 bar
• Fluke-719Pro-150G -12 to 150 PSI / -0.8 to 10 bar
• Fluke-719Pro-300G -12 to 300 PSI / -0.8 to 20 bar
• Unique integrated electric pump for one handed pressure calibration
• Pressure measurement from internal or external sensor
• Sourced/simulated or measured mA values
• Temperature measured by optional RTD probe

 

CURRENT CLAMP METER AC/DC TRUE-RMS 2000 A FLUKE 355

• 2000 A AC + DC true-rms, 1400 A AC, and 2000 A DC
• large 58 mm (2.3 in) jaw capacity
• 1000 V AC + DC true-rms, 600 V AC, and 1000 V DC
• Accurately measure frequency up to 1 kHz
• Resistance to 400 Kohms

 

DOCUMENTING PROCESS CALIBRATOR FLUKE 753

• Measure volts, mA, RTDs, thermocouples, frequency
• ohms to test sensors, transmitters and other instruments
• Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure
• Power transmitters during test using loop supply with simultaneous mA measurement

 

FLUKE TIS40 INFRARED CAMERA 160X120

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

WIRELESS AC FLEXIBLE CURRENT CLAMPMETER FLUKE CNX I3000 IFLEX

• True-RMS AC current measurements to 2500 A
• 3% accuracy
• Memory recording up to 65,000 readings
• iFlex current probe allows you to get into tight, awkward spaces
• Backlit LCD display
• CAT IV 600 V, CAT III 1000 V


FLUKE 1623-2 GEO EARTH GROUND RESISTANCE TESTER

• 3- and 4-pole Fall-of-Potential, earth resistance loop testing
• 4-pole Soil Resistivity testing
• Selective earth ground rod testing using 1 clamp
• Stakeless earth ground rod testing using 2 clamps
• IP56 rated for outdoor use
• Rugged carrying case
• USB data storage and transfer

 

INTRINSICALLY SAFE PRESSURE CALIBRATOR FLUKE 718

• ATEX II 1G Ex ia IIC T4 Compliant
• Built-in pressure / vacuum hand pump
• Pressure measurement to 0.05%
• Pressure measurement to 200

 

ELECTRIC TESTER 1000V VOLTAGE CONTINUITY CURRENT FLUKE T5-1000

• 1000V model
• Automatically measures V AC, V DC with precise digital resolution
• 100 A AC Current
• Displays resistance to 1000O

 

FLUKE 1507 MEGOHMMETER INSULATION MULTIMETER 50/ 1000V

• Insulation test range: 0.01 MO to 10 GO
• Insulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V