RFI/ EMI Control Filters for Alarm, Detection and Monitoring Systems ETS-Lindgren N296X/ N2972

Code: ETS-Lindgren N296X/ N2972


 

Datasheet PDF, 1.3 Mb

Description

  • Tubular, flat-pack or modular design
  • Attenuation from 100dB at 10kHz
  • Suitable for EMI, EMP and Tempest protection
  • 24V DC and 250V AC/DC options

 

Current Rating

0.3 Amps

Number of Lines

10

Voltage Frequency Maximum

250V DC 50/60Hz

 

More products ETS-LINDGREN

MAGNETIC SHIELDED COIL ANTENNA LOW FREQUENCIES 20 HZ..500 KHZ ETS-LINDGREN 7604

• Frequency Minimum 20 Hz
• Frequency Maximum 500 kHz
• Connectors Type BNC
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

BROADBAND BICON ANTENNA FOR CHAMBER CHARACTERIZATION 1..18 GHZ ETS-LINDGREN 3183

• Frequency Minimum 1 GHz
• Frequency Maximum 18 GHz
• VSWR Ratio (AVG) 2:1
• Maximum Continuous Power 50 watts @ 1GHz, 25 watts @ 18 GHz
• Chamber Characterization
• Broadband Spectrum

 

REVERBERATION TEST CELL FOR RADIATED IMMUNITY AND EMISSIONS MEASUREMENTS ETS-LINDGREN SMART 1000

• Automated Measurement with Optional Software
• Field Uniformity Better than 3 dB Over Operating Range
• Compact Bench-Top Design
• Frequency Range of 1.0 GHz to 40 GHz
• Radiated Immunity and Emissions Measurements

 

ACOUSTIC TEST ENCLOSURE FOR SMALL DEVICES ETS-LINDGREN SD

• Acoustically Controlled Test Environment
• Survey and/or Engineering Grade Measurement
• Applicable Test Standards: ISO 30744, GM W7293, GM W14011

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ EMP APPLICATIONS CURRENTS 16..200A ETS-LINDGREN N600X

• Suitable for 400Hz supplies
• Compact Rugged Construction
• Maximum Protection for EMP and Tempest applications
• Current Range 16 to 200 Amperes
• 100 dB Insertion Loss from 14 kHz to 40 GHz
• Low power dissipation

 

HORIZONTAL/ VERTICAL ELECTRIC FIELD GENERATOR 10 KHZ..30 MZ ETS-LINDGREN 5502

• Generates vertical or horizontal electric field
• Generates Fields 200 v/m in the 10 kHz to 30 MHz Frequency Range
• Fully Adjustable Height and Separation of Main Conductors
• Large Immunity Volume
• Chamber Supported

 

SHIELDED TEST CELL ENCLOSURE FOR WIRELESS MEASUREMENTS ETS-LINDGREN 5247

• Roll-About Casters
• Portable RF Shielded Enclosure for OTA measurements
• >80 dB Typical RF Isolation
• RF Absorber Lined
• Dual Polarized Horn Antenna
• 700 MHz - 10 GHz Frequency Range
• Linear & Circular Polarization

 

HIGH PERFORMANCE CONTROL FILTERS FOR TEMPEST/ EMP/ EMI APPLICATIONS CURRENTS 2..10A ETS-LINDGREN N502X/ N503X

• Current Rating 2 Amps
• Number of Lines 2
• Voltage Frequency Maximum 100/DC
• Current range up to 10 Amperes
• Protection for Tempest and EMP
• Low volt drop
• AC and DC Options

 

INDUCED RF CURRENT METER 9 KHZ..70 MHZ ETS-LINDGREN HI-3702

• Wide Frequency Response (9 kHz - 70 MHz)
• Eliminates concern over foot contact and body orientation
• Monitors induced current while standing, walking, or climbing.
• Thermally based True RMS Converter Circuit for increased accuracy

 

OCTAVE HORN ANTENNA LINEAR POLARIZED 1..8 GHZ ETS-LINDGREN 3161

• Frequency Minimum 1 GHz
• Frequency Maximum 8 GHz
• Pattern Type directional
• Polarization linear
• Constant Antenna Factor Over Frequency
• Complete with Feed, Waveguide, Mount