Field Generating Pyramidal Horn Antenna for EMC Automotive Testing ES-XW7T-1A278-AC 2.7..3.1 GHz ETS-Lindgren 3162-02

Code: ETS-Lindgren 3162-02


 

Datasheet PDF, 0.14 Mb

Description

  • Frequency Minimum     2.7 GHz
  • Frequency Maximum    3.1 GHz
  • Connectors       Type N
  • Impedance (Nominal)   50 ?
  • Maximum Continuous Power    300 W
  • Pattern Type     directional
  • Polarization       linear
  • VSWR Maximum         2:1
  • VSWR Typical 1.5:1
  • Generates 600 V/m with < 300W
  • Meets Specs for ES-XW7T-1A278-AC
 

More products ETS-LINDGREN

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5405

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

BICONICAL ANTENNA FOR TESTING IEC 1000-4-3 20..300 MHZ ETS-LINDGREN 3109

• Frequency Minimum 20 MHz
• Frequency Maximum 300 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW
• Pattern Type omnidirectional
• Peak Power 3 kW
• Polarization linear

 

ELECTROMAGNETIC LEAKAGE METER OF MICROWAVE OVEN ETS-LINDGREN HI-1501

• Three Ranges
• Calibrated at 2450 MHz
• Battery Operated
• Extra sensitivity for Compliance Measurement

 

RF ELECTROMAGNETIC SURVEY METER ETS-LINDGREN HI-2200

• Handstrap & Safety Lanyard Mount
• Optional Fiber Optic Link
• Interchangeable Probe Heads
• Small/Lightweight for minimal field perturbance
• Broadband Frequency Range
• Economical Solution to Broadcast/Telecom Safety Monitoring Needs & Environmental Monitoring

 

ELF MAGNETIC FIELD SURVEY METER 5..2000 HZ ETS-LINDGREN HI-3627

• 5 - 2000 Hz
• 0.2 mG - 20 G
• Three Concentric Orthogonal Field Sensors
• True RMS Detection
• Isotropic Response
• 100dB Dynamic Range

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5402

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

HIGH CURRENT POWER PROTECTION FILTERS IN THREE PHASE NETWORK AND RFI/EMP SYSTEMS 400..800A ETS-LINDGREN N258X

• Current Rating 800 Amps
• Frequency 50/60 Hz
• Number of Lines 4
• Voltage Frequency Maximum 440/250
• Tempest Capability
• Ideal for EMPP systems

 

POWER FILTERS FOR RFI/ EMI RADIATION PROTECTION WITH LOW EARTH LEAKAGE CURRENTS 6..100A ETS-LINDGREN N242X

• Suitable for mobile installations
• Extremely low current leakage
• Over 100dB insertion loss from 150 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ EMP APPLICATIONS CURRENTS 16..200A ETS-LINDGREN N600X

• Suitable for 400Hz supplies
• Compact Rugged Construction
• Maximum Protection for EMP and Tempest applications
• Current Range 16 to 200 Amperes
• 100 dB Insertion Loss from 14 kHz to 40 GHz
• Low power dissipation

 

ELECTROMAGNETIC LEAKAGE AUTOMATIC SCANNING METER OF MICROWAVE OVEN ETS-LINDGREN HI-1710A

• Digital Alarm Set
• Auto-ranging
• RS-232 Interface
• Removable Sensing Probe
• Optional Remote Zero
• Analog bar graph
• Serial Printer Output