Fluke 8808A Digital Bench Multimeter 5.5 digit
• 5.5 digit resolution • Basic V dc accuracy of 0.015 % • Dual display
| |||
![]() |
Fluke 8845A Digital Bench Multimeter 6.5 digit
• 6.5 digit resolution • Basic Vdc accuracy 0.0035 % • Dual display • 100 μA to 10 A current range, with up to 100 pA resolution
| |||
![]() |
Fluke 8846A Digital Bench Multimeter 6.5 digit
• 6.5 digit resolution • Basic Vdc accuracy 0.0024 % • Dual display • 100 μA to 10 A current range, with up to 100 pA resolution
| |||
![]() |
Fluke 8508A Digital Reference Multimeter 8.5 digit
• 8.5 digit • 2.7 ppm stability
| |||
![]() |
Fluke 233 Handheld Digital Multimeter 3.5 digit
• 3.5 digit • 6000 count • 0.25% accuracy • Remote Display • Measure up to 1000 V ac and dc • Measure up to 10 A (20 A for 30 seconds) • 10,000 μF capacitance range • Frequency to 50 kHz • True-rms ac voltage and current for accurate measurements on non-linear signals
| |||
![]() |
Fluke 113 Handheld Digital Multimeter 3 1/2 digit
• 3.5 digit • 6000 count • 0.5% accuracy • True-rms for accurate ac measurements on non-linear loads • VCHEK™ LoZ low impedance measurement function to simultaneously test for voltage or continuity
| |||
![]() |
Fluke 114 Handheld Digital Multimeter Electrical 3.5 digit
• 3.5 digit • 6000 count • 0.5% accuracy • AutoVolt: automatic ac/dc voltage selection
| |||
![]() |
Fluke 115 Handheld Digital Multimeter 3.5 digit
• 3.5 digit • 6000 count • 0.5% accuracy • AC/DC Current • Capacitance and Frequency
| |||
![]() |
Fluke 116 Handheld Digital Multimeter HVAC 3.5 digit
• 3.5 digit • 6000 count • 0.5% accuracy • Built-in thermometer for HVAC applications • Microamps to test flame sensors
| |||
![]() |
Fluke 117 Handheld Digital Multimeter Electrician 3.5 digit
• 3.5 digit • 6000 count • 0.5% accuracy • VoltAlert™ technology for non-contact voltage detection • AutoVolt automatic ac/dc voltage selection
| |||
![]() |
Fluke 175 Handheld Digital Multimeter 3.5 digit
• 3.5 digit • 6000 count resolution • 0.15% basic accuracy • True RMS voltage and current measurements
| |||
![]() |
Fluke 177 Handheld Digital Multimeter 3.5 digit
• 3.5 digit • 6000 count resolution • 0.09% basic accuracy • True RMS voltage and current measurements • Digital display with analog bargraph and backlight
| |||
![]() |
Fluke 179 Handheld Digital Multimeter 3.5 digit
• 3.5 digit • 6000 count resolution • 0.09% basic accuracy • True RMS voltage and current measurements • Digital display with analog bargraph and backlight • Temperature measurements
| |||
![]() |
Fluke 77IV Handheld Digital Multimeter 3.5 digit
• 3.5 digit • 6000 count resolution • 0.3% basic accuracy • Large display • Backlight for work in dim areas
| |||
![]() |
Fluke 83V Handheld Digital Multimeter 3.75 digit
• 3.75 digit • 6000 count resolution • 0.1% basic accuracy
| |||
![]() |
Fluke 87V Handheld Digital Multimeter 4.5 digit
• 4.5 digit • 20,000 count resolution for precise measurements • 0.05% basic accuracy • True-rms ac voltage and current for accurate measurements on non linear signals • Selectable filter for accurate voltage and frequency measurements on motor drives • Built in thermometer lets you carry one less tool (TC probe included)
| |||
![]() |
Handheld Digital Multimeter ATEX Safe 4.5 digit Fluke 87V Ex
• 4.5 digit • 6000 count resolution for precise measurements • 0.05% basic accuracy • True-rms ac voltage and current for accurate measurements on non linear signals • Selectable filter for accurate voltage and frequency measurements on motor drives • Built in thermometer lets you carry one less tool (TC probe included) • ATEX safety rating Ex II 2 G Eex ia IIC T4
| |||
![]() |
Fluke 27 II Handheld Multimeter Rugged IP67 Industrial 4.5 digit
• 4.5 digit • 20,000 count resolution for precise measurements • 0.05% basic accuracy • New – IP 67 waterproof & dustproof protection, completely sealed for use in harsh environments
| |||
![]() |
Fluke 28 II Handheld Multimeter Rugged IP67 Industrial 4.5 digit
• 4.5 digit • 20,000 count resolution for precise measurements • 0.05% basic accuracy • New – IP 67 waterproof & dustproof protection, completely sealed for use in harsh environments • Peak min-max • True-rms ac voltage and current for accurate measurements on non linear signals • Built in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
| |||
![]() |
Fluke 88V/A Deluxe Automotive Kit Digital Multimeter 4.5 digit
• 4.5 digit high resolution mode for precise measurements • 20,000 count • 0.1% dc accuracy • Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument • Conductance for coil testing • Magnetic hanger (included with kit) for easy set-up and viewing while freeing your hands for other tasks
| |||
![]() |
Fluke 287 Handheld Digital Data Logging Multimeter 4.5 digit
• 4.5 digit large ¼ VGA display with white backlight • 50,000 count • 0.025% basic accuracy • Logging function with TrendCapture
| |||
![]() |
Fluke 289 Handheld Digital Data Logging Multimeter 4.5 digit
• 50,000 count • 0.025% basic accuracy • Logging function with TrendCapture • Low input impedance function (LoZ) • Motor winding and low ohm measurement range • Low pass filter
| |||
![]() |
Fluke CNX 3000 Wireless Digital Multimeter
• AC and DC voltage measurements to 1000V • AC and DC current with 0.01 mA resolution • Continuity, resistance, diode test, capacitance and frequency measurements • MIN/MAX Recording • CAT III 1000 V, Cat IV 600V; IP54
| |||
![]() |
Wireless AC Flexible Current Clampmeter Fluke CNX i3000 iFlex
• True-RMS AC current measurements to 2500 A • 3% accuracy • Memory recording up to 65,000 readings • iFlex current probe allows you to get into tight, awkward spaces • Backlit LCD display • CAT IV 600 V, CAT III 1000 V
| |||
![]() |
Wireless AC Voltage Module Fluke CNX v3000
• True-RMS AC voltage measurements to 1000V • ±1% accuracy to 500 Hz, ± 2% accuracy to 1 kHz • Memory recording up to 65,000 readings • Backlit LCD display • CAT IV 600 V, CAT III 1000 V; IP42
| |||
![]() |
Wireless Current Clamp Fluke CNX a3000
• True-RMS AC current measurements to 400 A • 2% accuracy to 100 Hz, 2-1/2% accuracy to 500 Hz • Memory recording up to 65,000 readings • Backlit LCD display • CAT III 600 V; IP42
| |||
![]() |
Wireless Temperature K-Type Acquisition Module Fluke CNX t3000
• Temperature measurements from -200 °C to 1372 °C • ± 0.5% accuracy • Memory recording up to 65,000 readings • Backlit LCD display • IP30
| |||
![]() |
Wireless AC Current Measurement Kit FLK-CNX i3000 iFlex kit
• True-RMS AC and DC voltage measurements to 1000V • True-RMS AC and DC current with 0.01 mA resolution • True-RMS AC current measurements to 2500 A • Memory recording up to 65,000 readings • CAT III 1000, CAT IV 600 V; IP42
| |||
![]() |
AC Voltage Data Acquisition Recording Kit Fluke FLK-CNX v3000 kit
• True-RMS AC and DC voltage measurements to 1000V • True-RMS AC and DC current with 0.01 mA resolution • True-RMS AC voltage measurements to 1000V • Memory recording up to 65,000 readings • CAT III 1000 V; CAT IV 600 V; IP42
| |||
![]() |
Remote AC Current Measurement Kit with Current Clamp Fluke FLK-CNX a3000 kit
• True-RMS AC and DC voltage measurements to 1000V • True-RMS AC and DC current with 0.01 mA resolution • True-RMS AC current measurements to 400 A • Memory recording up to 65,000 readings • CAT III 600 V; IP42
| |||
![]() |
Wireless Temperature K-Type Data Acquisition Measurement Kit Fluke FLK-CNX t3000 kit
• True-RMS AC and DC voltage measurements to 1000V • True-RMS AC and DC current with 0.01 mA resolution • Temperature measurements from -200 °C to 1372 °C • Memory recording up to 65,000 readings
| |||
![]() |
Industrial Voltage and Current Measurement System Fluke CNX 3000 IND
• True-RMS AC and DC voltage measurements to 1000V • True-RMS AC and DC current with 0.01 mA resolution • True-RMS AC current measurements to 2500 A • True-RMS AC voltage measurements to 1000V • CAT III 1000 V, CAT IV 600 V, CAT III 1000 V; IP42
| |||
![]() |
Industrial Measurement System Fluke CNX 3000 HVAC
• True-RMS AC and DC voltage measurements to 1000V • True-RMS AC and DC current with 0.01 mA resolution • Temperature measurements from -200 °C to 1372 °C • True-RMA AC current measurements to 400 A
| |||
![]() |
Industrial Maintenance System Fluke CNX 3000 GM
• • True-RMS AC and DC voltage measurements to 1000V • • True-RMS AC and DC current with 0.01 mA resolution • • True-RMS AC voltage measurements to 1000V • • True-RMS AC current measurements to 2500 A
| |||
![]() |
Wireless Measurement System Fluke CNX 3000 Series
• Fluke CNX 3000 Wireless Multimeter • Fluke CNX v3000 AC Wireless Voltage Module • Fluke CNX i3000 iFlex AC Wireless Current Module • Fluke CNX a3000 AC Wireless Current Clamp Module • Fluke CNX t3000 K-Type Wireless Temperature Module
| |||
![]() |
FLUKE 279 FC TRMS Digital Thermal Multimeter with termovision
• Full-featured multimeter with built-in thermal imager • 15 measurement functions including: AC voltage with low-pass filter, DC voltage, Resistance, Continuity, Capacitance, Diode test, Min/Max/Avg, AC current (with iFlex), Frequency • Image resolution–80 x 60 • 3.5 in /8.89 cm color LCD screen • CAT III 1000 V, CAT IV 600 V measurement category
|