Standalone or computer-controlled
-
Inexpensive
-
Displays turns-ratio from 0.8-15,000
-
Calculates turns-ratio percentage error
-
Displays winding polarity and phase angle
-
Displays excitation current
-
Battery or AC-powered (ATRT-01B S3 only)
The ATRT-01 S3 is Vanguard’s fourth generation, micro-processor based, single phase, automatic transformer turns-ratio tester. The ATRT-01 S3 uses the IEEE C57.12.90 measuring method to determine the transformer turns-ratio. The transformer turns-ratio is determined by precisely measuring the voltages across the unloaded transformer windings. The ATRT-01 S3’s measuring circuitry self adjusts before each measurement to ensure turns-ratio accuracy. Two selectable test voltages, 4Vac and 40Vac, offer flexibility in testing different types of transformers.
The ATR-01 S3 can measure transformer turns-ratios
ranging from 0.8 to 15,000 and can be used to test voltage
regulators, power transformers, current transformers
(CT), and potential transformers (PT). The ATRT-01
S3 also measures and displays transformer- winding
excitation current, winding polarity, and winding phase
angle. Test results are displayed on a back-lit LCD screen
(128 x 64 pixels) that is viewable in bright sunlight and
low-light conditions.
In addition to measuring a transformer’s turns-ratio, the
transformer’s name plate voltages can also be entered,
and the ATRT-01 S3 will then display the turns-ratio
percentage error. This convenient feature eliminates any
user calculation errors when testing transformers.
When testing a 3-phase transformer, the ATRT-01 S3
provides connection information (H and X test leads to
the transformer bushings) for phase A, B and C tests.
The three phase test results (turns-ratio, excitation current,
winding polarity, phaseangle, and percentage error)
are displayed on the LCD screen.
User Interface
The ATRT-01 S3 features a back-lit LCD screen
(128 x 64 pixels) that is viewable in direct sunlight
and low-light levels. A rugged 16-key membrane
keypad is used to enter test information
and to operate the unit.
Test Record Storage
The ATRT-01 S3 can store 128 records of 33 readings
internally, and up to 999 test records on an
external USB Flash drive. Test records can be
recalled using the included Transformer Analysis
PC software.
Computer Interface
A Windows®-based Transformer Analysis application
is provided with each unit and can be
used to remotely control the ATRT-01 S3 via the
RS-232C port. Using the Transformer Analysis
software, the user can retrieve test records
(from the ATRT-01 S3’s memory or a USB Flash
drive), analyze test results, and print test results
on a desktop printer. Test results are automatically
exported to Excel, PDF and XML formats.
Battery Power for Exceptional Portability
The ATRT-01B S3 is powered by a 6-volt, 7
ampere-hour, lead acid battery. This high capacity
battery, coupled with the ATRT-01B S3’s low
power consuming circuitry, allows the unit to be
used continuously for up to 4 hours per charge.
A built-in charger allows the unit to be used during
charging.