Teslametru digital de laborator citire cu efect Hall Brockhaus GM-425 testare nivel campuri magnetice senzor axial transversal Tesla Gauss tester aparat

    office@distek.ro     ROM     ENG  
Login | Creeaza cont | Ai uitat parola?
Cosul de produse  Produse: 0 | Total: 0    
 
 
    Home |  Despre noi |  Noutati |  Promotii |  Reduceri |  Servicii |  Tech Library |  Cum comanzi? |  Harta site |  Contact
 
 
Produse         [+ Expand]   [- Colapse]

Testere camp electromagnetic > BROCKHAUS (11) > Teslametru digital de laborator citire cu efect Hall Brockhaus GM-425

 


  ..  Navigator produse [3] din [11]    ..
 

Teslametru digital de laborator citire cu efect Hall Brockhaus GM-425

Cod: Brockhaus GM-425
 
BROCKHAUS
 

» Specificatii tehnice

  • Digital laboratory Gaussmeter for determining the magneticfield strength of permanent magnets and systems
  • Measurement of magnetizing pulses up to 10 kHz
  • User-friendly measuring instrument
  • Mains supply
  • Application in laboratories and in production lines
  • Field and temperature measurement via the probe input

 

Operating principle

Single-channel Gaussmeter with a resolution of 4 ¾ digits with filter in DC-adjustment and a measuring accuracy of ± 0.20 % of the measured value. The measuring rate is 3 measurements per second (display) and 30 measurements per second with USB interface. Measurement of Hall voltage created in Hall sensor which is proportional to the applied magnetic field.

All the functions are displayed and controlled via the front panel of the instrument. Input via keyboard, readings on a 2-line LCD display with background light. Two analogue outputs are provided. The corrected analogue output displays the exact value, the non-corrected analogue output shows the field strength in real time. Field and temperature measurements are via the probe input.

The Gaussmeter 425 DSP is used e.g. for testing magnetic materials in sensor technology and in automation. It can also function as an integrated component in controlling production processes and in the manufacture of DC motors.

 

 

Technical data:

Gaussmeter 425

Measuring mode:

measurement of Hall voltage

Measuring range:

350 mG, 3.5 G, 35 G, 350 G, 3.5 kG, 35 kG, 350 kG

Measuring frequency:

DC, AC up to 10 kHz

Measuring accuracy:

± 0,2 % of DC value, ± 2 % of AC value 0,005 % of measuring range

Repeatability:

± 0,1 %

Measuring rate:

3 measurements/sec / display 
30 measurements/sec / interface

Selection of measuring range:

automatic or manual

Resolution:

4 3/4 digits

Display:

2-line, LCD lighted

Probe type:

all DSP single-axis laboratory probes

Temperature range:

5°C - 40°C

Analogue outputs:

corrected and non-corrected ± 3,5 V

Interfaces:

USB

Power supply:

100 – 240 V AC, 50 / 60 Hz

Functions:

Max Hold, Alarm with Relay, Zero Probe, Relative Reading, Auto Range, AC/DC, Keylock

Accessories:

Zero gauss chamber
Terminal block
Power cable
USB driver CD
Maual

Special accessories:

probe cable in lengths 3 / 7,6 / 15,24 / 30,49 m
305 mm zero chamber
Interface cable
19" drawer

 

 



» Accesorii standard incluse

 



» Optiuni, Servicii si Accesorii recomandate

GAU-005002 Zero field chamber BZC-101

GAU-005004 Additional axial probe BAP-101

GAU-005005 Additional transversal probe BTP-101

GAU-005003 Aluminum hard case

GAU-005006 Probe extension cable (1 m) BPC-101
 

Hall probes overview Gaussmeter

 

Axial Probes

Model

L

D

A

Stem Material

Corrected accuracy (%) of reading

Temperature coefficient (maximum) zero

Temperature coefficient (maximum) calibration

MMA-2502-VH

2 " ± 0.063"

0.25" ± 0.006''

0.010"

Aluminum

± 0.25 % to 30 kG

± 0.09 G/°C

- 0.04 %/°C

MNA-1904-VH

4' ± 0.125"

0.187" ± 0.005''

0.005''

Fiberglass
epoxy

MMA-2502-VG

2" ± 0.063''

0.25" ± 0.006''

0.010"

Aluminum

± 0.15 % to 30 kG

± 0.13 G/°C

- 0.005 %/°C

MNA-1904-VG

4' ± 0.125"

0.187" ± 0.005''

0.005"

Fiberglass
epoxy

 

Transverse Probes

Model

L

D

A

Stem Material

Frequency Range

Corrected accuracy (%) of reading

Temperature coefficient (maximum) zero

Temperature coefficient (maximum) calibration

MMT-6J04-VH

4"± 0.125"

0.061" max

0.180"

Aluminum

DC

± 0.25 % to 30 kG

± 0.09 G/°C

- 0.04 %/°C

MNT-4E04-VH

0.045" max

0.150''

Rigid glass epoxy

DC and 10 Hz to 400 Hz

MMT-6J04-VG

0.061" max

0.180"

Aluminum

DC

± 0.15 % to 30 kG

± 0.13 G/°C

- 0.005 %/°C

MNT-4E04-VG

0.045" max

0.180"

Rigid glass epoxy

DC and 10 Hz to 400 Hz

 

Flexible Transverse Probes

Model

W

T

Active Area

Stem Material

Frequency Range

Corrected accuracy (%) of reading

Temperature coefficient (maximum) zero

Temperature coefficient (maximum) calibration

MFT-3E03-VH

0.135" max

0.025" max

0.040" dia (approx)

Flexible
Tubing

DC and 10 Hz to 400 Hz

± 0.25 % to 30 kG

± 0.09 G/°C

- 0.04 %/°C

MFT-3E03-VG

± 0.15 % to 30 kG

± 0.13 G/°C

- 0.005 %/°C

 

 

Home |  Despre noi |  Noutati |  Promotii |  Reduceri |  Servicii |  Tech Library |  Termeni şi Condiţii |  Cum comanzi? |  Link-uri utile |  Harta site |  Contact |  Politica Cookie

        