Modul multiplexor 70 canale Agilent 34924A

Cod: Agilent 34924A


 

Brosura produs PDF, 1.43 Mb

Descriere

  • 70 2-wire channels
  • Mixed 2- or 4-wire configurations
  • High-speed reed relays, with relay counter
  • 500 ch/s scanning
  • +/-150V peak, 0.5A switch
  • 1.5A carry current
 

Alte produse KEYSIGHT

ANALIZOR DE SPECTRU PORTABIL 9/100 KHZ..3 GHZ AGILENT N9340B HSA

• 100 kHz to 3 GHz Frequency range(tunable to 9 kHz)
• 30 Hz to 1 MHz RBW
• 3 Hz to 1 MHz VBW

 

GENERATOR SEMNAL VECTORIAL 100 KHZ..3 GHZ/ 6 GHZ AGILENT N5182A MXG

• 100 kHz to 3 GHz or 6 GHz
• 0.01 Hz resolution
• >+23 dBm up to 3 GHz using a highly-reliable, fast-switching electronic attenuator
• 100 MHz internal I/Q baseband generator
• Up to 64 MSa playback memory and 800 MSa storage

 

SARCINI ELECTRONICE PROGRAMABILE MODULARE 600-1800W AGILENT N3300A

• 6 Slots - Full Rack Width Mainframe(N3300A Mainframe)
• 1800 Watts of Total Maximum Power(N3300A Mainframe)
• 2 Slots - Half Rack Width Mainframe(N3301A Mainframe)
• 600 Watts of Total Maximum Power(N3301A Mainframe)
• 
• 6 Modules available for configuring (150W to 600W)
• Max Voltage Input: 240V (N3303A)
• Max Current Input: 120A (N3306A)

 

FRECVENTMETRU RF UNIVERSAL 12 DIGIT 2 CH 350 MHZ AGILENT 53220A

• 2 x 350 MHz baseband frequency
• 12 digits/sec resolution
• 6 or 15 GHz optional microwave channels
• 100 ps single-shot time resolution

 

OSCILOSCOP DIGITAL 2 X 500 MHZ AGILENT DSOX3052A

• 500 MHz bandwidth
• 2 analog channels
• 2 GSa/s per channel sample rate, 4 GSa/s half-channel interleaved mode


GENERATOR MICROUNDE 250 KHZ..20 GHZ/ 31.8 GHZ/ 40 GHZ/ 50 GHZ/ 67 GHZ AGILENT E8257D PSG

• 250 kHz to 20 GHz, 31.8 GHz, 40 GHz, 50 GHz or 67 GHz operational to 70 GHz
• 0.001 Hz resolution
• +23 dBm @ 20 GHz, +17dBm @ 40 GHz, +14 dBm @ 67 GHz output power (typ); > +30 dBm (typ) with Option 521.
• AM, FM, ØM, pulse, and scan
• Extendable to 75, 90, 110, 140, 170, 220, 325, or 500 GHz

 

MULTIMETRU DIGITAL DE PRECIZIE 5.5 DIGIT SI SURSA ALIMENTARE AGILENT U3606A

• 5.5 digit
• 0.025% DC Voltage accuracy
• 120,000 counts resolution
• Single-output dual range of 30V/1A or 8V/3A

 

MODUL MATRICE DUAL/QUAD 4 X 8 AGILENT 34933A

• Dual 4x8, 8x8, or 4x16 2-wire configurations
• 64 2-wire or 128 1-wire cross-points
• High-speed reed relays

 

GENERATOR SEMNAL RF 9 KHZ..3 GHZ AGILENT N9310A

• 9 kHz to 3 GHz
• 0.1 Hz resolution
• 20 Hz to 80 kHz low frequency (LF) output
• -127 to +13 dBm output level range (maximum +20 dBm settable)
• Optional IQ modulator, 40 MHz bandwidth

 

OSCILOSCOP DIGITAL 4 X 500 MHZ CU ANALIZOR LOGIC 16 CANALE AGILENT MSO7054B

• 500 MHz bandwidth
• 4 GSa/s sample rate
• 4 analog plus 16 digital channels
• Standard 8 Mpts MegaZoom III deep memory