Modul matrice dual 4 x 8 Agilent 34931A

Cod: Agilent 34931A


 

Brosura produs PDF, 1.43 Mb

Descriere

  • Dual 4x8, 8x8, or 4x16 configurations
  • 64 2-wire cross-points
  • Connections to the internal DMM
  • Expandable via four 2-wire analog buses
  • Relay counter
  • Latching armature relays
  • 300V, 1A switch
  • 2A carry current
  • 30 MHz Bandwidth
 

Alte produse KEYSIGHT

ANALIZOR LOGIC PORTABIL 68 CANALE AGILENT 16802A

• 68-channel portable logic analyzer
• 4 GHz (250 ps) timing zoom with 64 K memory
• 1.0 GHz / 500 MHz (half / full-channel) conventional timing with deep memory
• up to 450 MHz State clock rates
• up to 500 Mb/s Data rates
• up to 32 M acquisition memory depth

 

OSCILOSCOP PORTABIL DIGITAL 2 X 20 MHZ AGILENT U1602B

• 20 MHz bandwidth
• 2 analog channels
• 200MS/s sample rate
• 6000 count Digital Multimeter
• 125KS Maximum recording length viewable on screen with zoom function

 

MULTIMETRU DIGITAL MODULAR PCI PXI 6.5 DIGIT AGILENT M9183A

• 6.5 digit
• PCI PXI Modular Digital Multimeter
• 40 ppm accuracy
• Measurement speeds up to 20,000 rdgs/s
• DCV, DCI, ACV, ACI, 2- and 4-wire resistance

 

MODUL MULTIPLEXOR 70 CANALE AGILENT 34922A

• 70 2-wire channels
• Mix 2- or 4-wire configurations
• 100 ch/s scanning
• 300V, 1A switch
• 2A carry current
• 45 MHz Bandwidth

 

SURSE PROGRAMABILE MULTIPLE 25-160W AGILENT 662XA

• Multiple sources in an integrated one-box solution
• Dual-range linear outputs
• 2, 3 or 4 independent isolated outputs
• Stable, low ripple and noise power source
• Measured V & I readback over GPIB

 

OSCILOSCOP DIGITAL 4 X 500 MHZ CU ANALIZOR LOGIC 16 CANALE AGILENT MSOX3054A

• 500 MHz bandwidth
• 4 analog channels plus 16 digital channels
• 2 GSa/s per channel sample rate, 4 GSa/s half-channel interleaved mode


RLC-METRU DE PRECIZIE 20 HZ..2 MHZ AGILENT E4980A

• 20 Hz to 2 MHz
• 4-digit resolution in any range
• 0.05% basic accuracy
• Measurement parameters: |Z|, |Y|, ?, R, X, G, B, L, C, D, Q, Rdc, Idc, Vdc
• High-speed measurements up to 5.6 ms

 

RLC-METRU 100 HZ..100 KHZ AGILENT 4263B

• 0.1% basic accuracy
• 100 Hz, 120 Hz, 1 kHz, 10 kHz, 20 kHz, 100 kHz test frequencies
• Measurement parameters: Z, Y, Theta, R, X, G, B, C, L, D, Q, Rdc, N, M

 

SURSA PROGRAMABILA DE PRECIZIE 500W AGILENT 665XA

• Fast, low-noise Single outputs
• Linear output regulation
• Overvoltage & overcurrent protection
• Measured V & I readback over GPIB

 

OSCILOSCOP DIGITAL 2 X 100 MHZ AGILENT DSOX3012A

• 100 MHz bandwidth
• 2 analog channels
• 2 GSa/s per channel sample rate, 4 GSa/s half-channel interleaved mode