Generator de Impuls / Forme de unda arbitrare 500 MHz Agilent 81160A

Cod: Agilent 81160A


 

Brosura produs PDF, 1.18 Mb

Descriere

  • 1 µHz - 330 MHz pulse generation with variable rise/fall time
  • 1 µHz - 500 MHz sine waveform output
  • 14-bit, 2.5 GSa/s arbitrary waveforms
  • 1 or 2 channel, coupled and uncoupled
  • 256k samples deep arbitrary waveform memory per channel
  • Pulse, sine, square, ramp, noise and arbitrary waveforms
  • Noise, with an adjustable crest factor, and signal repetition time of 20 days
  • Differential outputs
  • FM, AM, PM, PWM, FSK modulation capabilities
  • Glitch free change of timing parameters
  • (delay, frequency, transition time, width, duty cycle)
  • Programming language compatible with Agilent 81101A, 81104A, 81105A , 81110A,
  • 81130A and 81150A
  • ISO 17025 and Z540.3 calibration
  • LXI class C compliant
  • Optional pattern generator:
  • Ideal and arbitrary bit shaped pattern up to 330 Mbit/s (Option 330) or 660 Mbit/s
  • (Option 660)
  • Three level signals
  • PRBS up to 231
  • 4 Mbit pattern memory for the 1-channel instrument and 2 Mbit per channel for the
  • 2-channel instrument
  • Pass through pattern for combined and physical and protocol test up to 10 Mbit/s
 

Accesorii standard

  •  Certificate of calibration
  •  Local power cord
  •  USB cable
  •  Agilent automation ready CD (Agilent I/O Library, IVI-COM driver)
  •  Product CD (user guide, getting started guide)
 

Optiuni recomandate

Options:

  • Opt.001    1-channel pulse function arbitrary noise generator
  • Opt.002    2-channel pulse function arbitrary noise generator
  • Opt.1A71 ISO17025 calibration documents
  • Opt.Z54   Z540.3 calibration documents
  • Opt.330   License for 330 Mbit/s pattern generator
  • Opt.660   License for 660 Mbit/s pattern generator
 

Alte produse KEYSIGHT

GENERATOR DE FUNCTII / FORME DE UNDA ARBITRARE 80 MHZ AGILENT 33250A

• 80 MHz sine and square waveforms
• 12-bit, 200 MSa/s, 64 Kpoint arbitrary waveforms
• 50 MHz pulse waveforms with variable rise/fall times
• Ramp, triangle, noise, DC and other waveforms

 

CLESTE DE CURENT TRUE-RMS 1000A AGILENT U1212A

• 1000 A DC and True-RMS AC current measurement
• Small body and large jaw size up to 52mm
• Includes full-featured DMM with resistance, capacitance, frequency, diode check, continuity
• K-Type temperature measurements

 

MODUL MATRICE QUAD 4 X 32 AGILENT 34934A

• 4x128, 8x64 or 16x32 1-wire configurations
• 4x64 or 8x32 2-wire configurations
• 100V, 0.5A switch/carry current

 

SURSA PROGRAMABILA DE INALTA PUTERE 6600W AGILENT 669XA

• Fast, low-noise Single outputs
• Linear output regulation
• Overvoltage & overcurrent protection
• Measured V & I readback over GPIB

 

MULTIMETRU DIGITAL MODULAR PCI PXI 6.5 DIGIT AGILENT M9183A

• 6.5 digit
• PCI PXI Modular Digital Multimeter
• 40 ppm accuracy
• Measurement speeds up to 20,000 rdgs/s
• DCV, DCI, ACV, ACI, 2- and 4-wire resistance

 

ANALIZOR LOGIC PORTABIL 136 CANALE AGILENT 16804A

• 136-channel portable logic analyzer
• 4 GHz (250 ps) timing zoom with 64 K memory
• 1.0 GHz / 500 MHz (half / full-channel) conventional timing with deep memory
• up to 450 MHz State clock rates
• up to 500 Mb/s Data rates
• up to 32 M acquisition memory depth

 

MODUL MULTIPLEXOR 40/80 CANALE AGILENT 34923A

• 40 2-wire channels or 80 1-wire channels
• Mixed 2- or 4-wire configurations
• High-speed reed relays, with relay counter

 

OSCILOSCOP DIGITAL 4 X 350 MHZ AGILENT DSO7034B

• 350 MHz bandwidth
• 2 GSa/s sample rate
• 4 analog channels
• Standard 8 Mpts MegaZoom III deep memory

 

RLC-METRU PORTABIL 120 HZ..1 KHZ AGILENT U1731A U1731B

• 20,000 counts resolution with dual display
• 120 Hz / 1 kHz test frequencies
• inductance, capacitance and resistance measurements

 

ANALIZOR LOGIC PORTABIL 34 CANALE AGILENT 16801A

• 34-channel portable logic analyzer
• 4 GHz (250 ps) timing zoom with 64 K memory
• 1.0 GHz / 500 MHz (half / full-channel) conventional timing with deep memory
• up to 250 MHz State clock rates
• up to 250 Mb/s Data rates
• up to 32 M acquisition memory depth