Tester multifunctional instalatii industriale si medicale 1000V HT Italia Maxtest2038
PRODUS OBSOLET ( * SCOS DIN UZ )

Cod: HT Italia Maxtest2038


 

Brosura produs PDF, 0.47 Mb

Descriere

  • Continuity of earth conductors with 200mA
  • Continuity of earth conductors with 10A
  • Insulation with 250, 500, 1000VDC
  • Earth resistance with 3-wire and 2-wire method
  • Ground resistivity
  • Line / Loop impedance measure P-N, P-P, P-PE
  • Line / Loop impedance measure P-N, P-P, P-PE with high resolution
  • Prospective short circuit current
  • Global earth resistance without RCDs tripping
  • Trip out time of RCD type A, AC, B and selective
  • Trip out real current of  RCD type A, AC, B and selective
  • Contact voltage
  • Frequency
  • Phase sequence indications
  • Percent Voltage Drop
  • Internal memory for saving test
  • Recall saved data at display
  • RS-232 serial interface
 

Accesorii standard

  • C2034: 4 wire cable with SHUKO plug
  • C5700: power supply cable for 10A test
  • C203802: 4 wire cable
  • C203803: 3 wire cable
  • C203804: 4 wire cable for earth test
  • C203805: cable with  SHUKO plug
  • KITTERRNE: set of 4 cables + 4 metal probes
  • COC4-UK: set of 4 alligator clips
  • 404-IECB: blue test lead
  • 404-IECN: black test lead
  • B84: carrying bag for accessories
  • TOPVIEW: Windows software + RS-232 serial cable C232NG1
  • User manual
  • ISO9000 calibration certificate
 

Optiuni recomandate

  • C203807: adapter for three phase measures
 

Alte produse HT ITALIA

MULTIMETRU CALIBRATOR DIGITAL PORTABIL DE PROCES HT ITALIA HT8000

• Generation of output voltage signal with amplitude up to 10VDC
• Voltage measurement up to 10VDC
• Generation of output current signal with amplitude up to 24mADC
• Current measurement up to 24mAVDC
• Current measurement in percentage format (4-20mA)
• Loop current measurement of external transducers

 

TESTER SECURITATE SISTEME PANOURI FOTOVOLTAICE HT PVCHECK

• Safety test of PV installation
• Continuity test on protective conductors with 200mA
• Insulation test with test voltage of 250, 500, 1000VDC
• DC voltage
• DC current
• DC Power
• Solar irradiation [W/m2] with reference cell

 

TESTER DIGITAL MASURARE PRIZE DE PAMANT SI REZISTENTA BUCLA IMPAMANTARE RCD HT ITALIA SPEED 418

• Tripping time on RCD type A, AC General and Selective with currents 10, 30,100, 300, 500mA
• Tripping time on RCD type AC General with currents 30, 30x5, 100, 300mA
• Tripping current on RCD type A, AC General and Selective Global earth resistance without RCD tripping
• Line/Loop impedance, also with high-resolution (0.1m )( with optional accessory IMP57)
• Optical/USB interface for connection to PC

 

ANALIZOR AUDIO CLASA 1 HT ITALIA HT155/ HT157

• Measuring range 25-140dB
• "Peak", "Fast", "Slow" and "Impulse" integrations
• "A", "C" and "Z (linear)" frequency weighting
• "Peak+" and "Peak-" measurement in C weighting
• Spectral analysis with octave and 1/3 octave digital filter (HT157)
• Class 1 portable calibrator
• Mini-USB output for connection to PC

 

MEGOHMMETRU IZOLATIE SI CONTINUITATE CU MULTIMETRU DIGITAL HT ITALIA M72

• Insulation Resistance with 250, 500VDC
• Measurement range up to 1GOhm
• Automatic discharging object after test
• Continuity test of protective conductors with 200mA
• DC Voltage
• AC TRMS Voltage

 

FULLTEST3 TESTER MULTIFUNCTIONAL SIGURANTA MASINILOR IEC/EN60204-1 SI TABLOURI DISTRIBUTIE JOASA TENSIUNE IEC/EN61439-1-2

• Măsurători IEC/EN60204-1 si IEC/EN61439-1-2
• Continuitatea circuitului de protecţie cu 200mA
• Continuitatea circuitului de protecţie cu I>10A, V<12V
• Continuitatea circuitului de protecţie cu I>25A, V<12V
• Izolaţie cu tensiuni de testare 100, 250, 500, 1000VDC
• Rigiditate dielectrică cu tensiune programabilă de la 250V la 5100VAC

 

TESTER TENSIUNE DE PAS SI DE CONTACT CURENT MAXIM 50A HT ITALIA HT2055

• Step/Contact voltage with separated units
• Synchronization between units
• Test current up to 50A
• Earth resistance measurement
• Ground resistivity measurement
• Internal memory for saving results
• USB and RS-232 ports for communication between units and PC

 

TERMOMENTRE FARA CONTACT INFRAROSU HT ITALIA

• Infrared temperature measurement from -50°C to 1000 °C
• Emissivity regulation
• Distance / Spot ratio of 50:1
• Laser pointer activation

 

MEGOHMMETRU DIGITAL PORTABIL IZOLATIE SI CONTINUITATE CONDUCTOARE IMPAMANTATE 4 GOHM 1000V HT ITALIA M70

• Insulation with test voltage 250, 500, 1000VDC
• Up to 4Gohm measurement range
• Automatic discharge of device under test
• LOCK feature for continuous measurements
• Programmable timer up to 60s
• Continuity of earth conductors with test current of 200mA
• A/DC voltage up to 600V
• Resistance and continuity test with buzzer

 

TESTER MULTIFUNCTIONAL SECURITATE INSTALATII ELECTRICE CU ANALIZA CALITATE PUTERE HT GSC60

• Izolaţie cu tensiune de 50, 100, 250, 500, 1000VDC
• Analiza calităţii energiei şi a consumului de energie trifazat
• Se pot înregistra 632 de parametri timp de peste două luni
• Diagramă vectorială tensiune/curent
• Forme de undă tensiune/curent
• Tabele sau histograme de armonici şi THD%
• Conexiune WiFi integrată şi compatibilitate cu aplicaţia HTANALYSIS