Megohmetru digital multimetru izolatie 50/ 1000V Fluke 1507

Cod: Fluke 1507


 

Brosura produs PDF, 0.27 Mb

Descriere

  • Insulation test range: 0.01 MO to 10 GO
  • Insulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V
  • Save both time and money with automatic calculation of Polarization Index and Dielectric Absorption Ratio
  • Make repetitive tests simple and easy with the Compare (Pass/Fail) function
  • Repetitive or hard-to-reach testing is easy with the remote test probe
  • Live circuit detection prevents insulation test if voltage >30 V is detected for added user protection
  • Auto-discharge of capacitive voltage for added user protection
  • AC/DC voltage: 0.1 V to 600 V
  • 200 mA Continuity
  • Resistance: 0.01 O to 20.00 kO
 

Accesorii standard

  • Remote probe
  • Test leads
  • Test probes
  • Alligator clips
  • User documentation
 

Optiuni recomandate

  • TL225 Stray Voltage Adapter Test Lead Kit
  • C101 C101 Hard Case
  • C25 Soft Meter Case
  • CXT170 CXT170 Extreme Case
  • TPAK ToolPak, Meter Hanging Kit
 

Alte produse FLUKE

CLESTE AMPERMETRIC DE CURENT TRUE-RMS AC/DC FLUKE 381

• Detachable digital display, read measurements up to 30 feet away
• iFlex fexible current probe included, 18-inch circumference
• 2500 A AC current measurement with iFlex
• 1000 A AC current measurement with fxed jaw
• 1000 V AC and DC voltage measurement
• True-rms AC voltage and current
• Frequency measurement to 500 Hz
• 60-k O resistance measurement
• 500 mV DC measurement range
• 1000 µF capacitance measurement

 

ANEMOMETRU MULTIFUNCTIONAL FLUKE 922

• Air Pressure
• Air Velocity
• Air Flow (Volume)
• Temperature

 

CLESTE AMPERMETRIC DE CURENT 400A FLUKE 322

• Measures AC current to 400 A with 0.1 A resolution
• Measures AC current to 40 A with 0.01 A resolution, precise low current measurements
• Measures AC volts to 600 V, with 0.1 V resolution to 400.0 V
• Measures DC volts to 600 V, with 0.1 resolution to 400.0 V
• Resistance measurement to 400 O
• Precise measurements with 1.8% basic accuracy

 

FLUKE 125B 125B/S SCOPEMETER OSCILOSCOP PORTABIL 2X40MHZ

• 2-canale 40MHz
• Osciloscop digital cu intrare dublă şi multimetru
• Lătime de bandă a osciloscopului de 40 MHz sau 20 MHz
• Două multimetre digitale true-RMS cu limită de numărare de impulsuri 5000
• Măsurarea energiei (W, VA, VAR, PF, DPF, Hz)
• Tensiune, curent şi armonice de energie
• Adaptor WiFi optional conectat la port USB intern pentru transfer wireless de informatii către PC, laptop sau aplicatia mobilă Fluke Connect®*1

 

LOCATOR DE TRASEU CABLURI ACOPERITE, INGROPATE, PRIN PERETI FLUKE 2042

• pentru detectarea cablurilor în pereti si sub pamânt
• pentru localizarea sigurantelor/întrerupatoarelor de pe circuitele finale
• pentru localizarea întreruperilor si a scurtcircuitelor din cabluri si din instalatiile de încalzire prin pardoseala
• detectarea tevilor metalice pentru apa sau încalzire

 

TELEMETRU LASER PORTABIL 60M FLUKE 416D

• Ability to measure up to 60 m (200 ft) with increased accuracy of up to 1.5 mm (0.06 in)
• Measurement to 30 m (100 ft) with accuracy of 3 mm (0.12 in)
• Instant measurement with one-button operation.
• Easy targeting with bright laser.
• Quick calculation of area and volume.
• Easy addition and subtraction of measurements.

 

SISTEM INDUSTRIAL MONITORIZARE FLUKE CNX 3000 HVAC

• masuratori de tensiune c.a. si c.c. true-rms, la 1.000 V
• curent c.a. si c.c. true-RMS, cu o rezolutie de 0,01 mA
• masuratori de temperatura de la -200 °C pâna la 1372 °C
• masuratori de curent c.a. true-RMA la 400 A


CALIBRATOR MULTIFUNCTIONAL DE PROCES FLUKE 726

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 20 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 4000 O Resistance measure / source / simulate
• 1 to 15 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure

 

CALIBRATOR MULTIFUNCTIONAL DE PROCES FLUKE 744

• 0 to 300 V DC/AC Voltage measure
• 0 to 15 V DC Voltage source / simulate
• 0 to 110 mA DC Current measure
• 0 to 22 mA DC Current source / simulate
• 0 to 11 kO Resistance measure / source / simulate
• 1 to 50 kHz Frequency measure / source / simulate
• PC interface and data logging
• Integrated HART communication

 

CALIBRATOR TEMPERATURA SI TERMOCUPLU FLUKE 714

• -200 to 1800șC Range Measure / simulate thrmocouple
• -10 to 75 mV Range Measure / simulate voltage
• Measure temperature from TC output