Filtre protectie Tempest/RFI/ EMI petru linii transmisii date Analogice/ Digitale ETS-Lindgren N2460

Cod: ETS-Lindgren N2460


 

Brosura produs PDF, 0.32 Mb

Descriere

  • Suitable for EMI and Tempest Protection
  • Digital and analogue transmissions
  • Tubular, flat-pack or modular design

 

Electrical Specifications

Current Rating

0.3 Amps

Number of Lines

10

Voltage Frequency Maximum

80V DC or AC (peak)

 

Alte produse ETS-LINDGREN

CELULA REVERBERANTA TESTE EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE RADIATA 1..40 GHZ ETS-LINDGREN SMART 1000

• Automated Measurement with Optional Software
• Field Uniformity Better than 3 dB Over Operating Range
• Compact Bench-Top Design
• Frequency Range of 1.0 GHz to 40 GHz
• Radiated Immunity and Emissions Measurements

 

TESTER MASURA RADIATII CAMP ELECTROMAGNETIC EMISE DE LINII TRANSMISIE RETELE ENERGIE ELECTRICA ETS-LINDGREN HI-3604

• Power Line Survey Instrument
• Wide Dynamic Range
• On-Board Data Logging
• Combination E & H Readings

 

ANTENA SPIRALA CONICA LOGARITMICA 1..10 GHZ ETS-LINDGREN 3102

• Frequency Minimum 1 GHz
• Frequency Maximum 10 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 50 W
• Pattern Type directional
• Peak Power 100 W
• Polarization circular
• VSWR 1.6:1
• Extremely low VSWR

 

ANTENA LOG-PERIODICA POLARITATE LINIARA DUBLA 100 MHZ..1.1 GHZ ETS-LINDGREN 3145BDP

• Frequency Range 100 MHz - 1.1 GHz
• Input Impedance 50 ?
• VSWR 1.5:1 average, 3.5:1 maximum
• Maximum RF input power 800 W
• Stainless Steel Construction
• Dual Linearly Polarized

 

ANTENA DIPOL DE PRECIZIE CALIBRARE & MASURA RIPLU COMUNICATII MOBILE SI INTERNET CTIA 450..5000 MHZ ETS-LINDGREN 3126

• Range of Frequencies to Cover Wireless Device Bands: 450…5000 MHz
• Meet CTIA +/- 0.1 dB Symmetry Requirement
• Precision Gain for Range Calibration

 

TESTER AUTOMATIC MASURA RADIATII CAMP ELECTROMAGNETIC EMISE DE CUPTOARELE CU MICROUNDE ETS-LINDGREN HI-1710A

• Digital Alarm Set
• Auto-ranging
• RS-232 Interface
• Removable Sensing Probe
• Optional Remote Zero
• Analog bar graph
• Serial Printer Output

 

ANTENA HORN DESCHISA CUADRI-CREASTA 100 MHZ..1 GHZ ETS-LINDGREN 3164-01

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• VSWR Ratio (AVG) 3:1 maximum
• 1.75:1 average
• Maximum Continuous Power 750 watts @ 100 MHz
• 200 watts @ 1 GHz
• Impedance (Nominal) 50 ?
• Connectors (2) Type N Female

 

TESTER MASURA ATENUARE RF SI ECRANARE ELECTROMAGNETICA 8..64 MHZ ETS-LINDGREN MF-130D

• Measurement frequencies: 8 MHz, 16 MHz, 32 MHz and 64 MHz
• Makes Shielding Attenuation
• MIL-STD-285 Measurements
• NSA 65-6 Measurements
• IEEE STD-299 Measurements
• EN 50147-1 Measurements
• Stores/Downloads up to 63
• Includes Windows® Compatible Easy-To-Use, Portable Software

 

ANTENA BICONICA LINIAR POLARIZATA 30..100 MHZ ETS-LINDGREN 3159

• Frequency Minimum 30 MHz
• Frequency Maximum 100 MHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 15 kW
• Pattern Type omnidirectional
• Polarization linear

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5405

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4