Measurement modes:
- SWR & S11
- Distance To Fault (Selectable: Meters or Feet)
- Smith Chart
- S11 & S21
- S21
- S11 & Smith Chart
- R, j, Z
SiteOne
Cable & Antenna Analyzer
Type 3028
The COMM-connect SiteOne Cable & Antenna Analyzer is a truly handheld analyzer covering all major communication bands from 50 kHz to 4400 MHz.
It has a large number of measurement screens available, in order to accommodate all the different parameters in an antenna installation.
Measurement screens can show 2 simultaneous graphs, from 2 different parameters in order to bring further clarity to your measurements
The built-in storage is accessible through the USB connector, and will show up on your PC as a temporary drive. The size of the internal storage is large enough to hold years of measurement data.
For documentation reference the instrument has a built-in real time clock
Simple multilayer menus are employed to setup and control the operation of the instrument
In order to ensure uninterrupted daily work, the instrument is equipped with LiIon cells capable of more than 4 hours of continuous work.
Accessory kit with soft carrying bag, Peli case, car charger and coax adapters for standard types are available
Applications / Features:
Fast Cable & Antenna measurements
Handheld
Lightweight
Rugged design
Cost effective
Document the performance of your installation
Graphic display
Large built-in storage
Colour LCD screen, visible in direct sunlight
Battery life saving, with ‘Auto Power off’ function
Built-In Real time clock
Hold and store data on internal SSD
Internal SSD accessible as simple USB drive on PC
Timestamped filesystem
Simple menu setup system
Specifications:
Frequency Center range: 50 kHz to 4.4 GHz
Frequency Center Resolution: 1 kHz
Frequency Span Range: 0/5 kHz to 4.4 GHz
Frequency Span Resolution: 5 Hz to 44 MHz
Frequency Accuracy: ±2.5 ppm
Distance To Fault End: 1 to 500 meter
( 1 to 1640 feet )
Distance To Fault Start: 0 to 99 m
( 0 to 324 feet )
Distance To Fault Resolution: 1 to 10 cm
( 0.4 to 4 inches )
Return Loss Measurement: 50 kHz to 1 MHz: < -30 dB
Conditions: 1 MHz to 100 MHz: < -35 dB
Tx Port 100 MHz to 1 GHz: < -30 dB
Factory Calibration 1 GHz to 2 GHz: < -30 dB
2 GHz to 3 GHz: < -28 dB
3 GHz to 3.8 GHz: < -25 dB
3.8 GHz to 4.4 GHz: < -20 dB
Transmission Measurement: 50 kHz to 1 MHz: > 40 dB
Dynamic Range 1 MHz to 100 MHz: > 80 dB
Conditions: 100 MHz to 1 GHz: > 70 dB
Rx Port 1 GHz to 2 GHz: > 50 dB
Factory Calibration 2 GHz to 3 GHz: > 50 dB
3 GHz to 4.4 GHz: > 40 dB
Impedance: 50 Ω
Connectors: 2 x “N” Female
USB Serial device (B type)
Display resolution: 320x240 pixels
Calibration storage: EEPROM
Operating time: approx. 4 hours
Operating temperature: 0° C to +50° C
Storage temperature: -30° C to +50° C
Size: 165 x 82 x 31 mm
Weight: Approx. 650 grams
Compliance: 89/336/EEC
92/31/EEC
93/68/EEC
EN 61000-6-4:2001
EN 61000-6-2:2005