Code: YOKOGAWA Low Pressure Calibrator CA700
Description
The Low Pressure Calibrator CA700 has a basic accuracy of 0.01% of reading on pressure measurement and 0.015% of reading on Current/Voltage source/measurement, which makes it the most accurate calibrator in the portable calibrator class. The CA700 also has the highest resolution and widest range of any hand held portable in its class with resolution of 0.001 kpa (200.00 kpa range) and a resolution of 0.0001 psi (29 psi range). The CA700 supports "As Found", "As Left" data and error rate (%). In addition the CA700 stores calibration procedures for pressure transmitters and pressure switched which allow strong support for field calibration and maintenance work. The CA700 is housed in a robust IP54 dust proof and water proof case for use in harsh environments. Available in three model ranges which includes low pressure, medium pressure or high pressure with selectable high-performance hand pumps for each range. A new high pressure module, the PM100, is now available, that effectively increases the pressure range of the CA700 (firmware versions 1.10 or later) to 2300 PSI, all the while maintaining the same basic accuracy of 001%.
The Low Pressure Calibrator CA700 is the most accurate calibrator in the portable calibrator class having a basic accuracy of 0.01% of reading on pressure measurement and 0.015% of reading on Current/Voltage source measurement. Supporting "As Found", "As Left" and error rate, makes the CA700 a great tool for field calibration and maintenance work. Available in low pressure, medium pressure or high pressure ranges with selectable high-performance hand pumps for each range.
Features:
More products YOKOGAWA
|
YOKOGAWA PROCESS MULTIMETER CA450
• Simultaneous 24 V loop power and mA measurement |
|
YOKOGAWA - MINI-MANOMETER MT10
• High reliability (with silicon resonant sensor) |
|
YOKOGAWA DIGITAL MULTIMETER TY520
• High Precision |
|
YOKOGAWA DIGITAL MULTIMETER TY710
• Conforms to safety standards EN61010-1 1000V CAT., 600V CAT. |
|
YOKOGAWA - DLM2000 MIXED SIGNAL OSCILLOSCOPES
• Lineup includes 200 MHz, 350 MHz, 500 MHz bandwidth models |
|
YOKOGAWA AQ6374 WIDE RANGE OPTICAL SPECTRUM ANALYZER 350 - 1750 NM
• High wavelength resolution: 0.05 to 10 nm |
|
YOKOGAWA - WT1800E HIGH PERFORMANCE POWER ANALYZER
• Harmonics analysis up to the 500th order of a 50/60 Hz fundamental frequency |
|
YOKOGAWA MULTIFUNCTION CALIBRATOR CA71 CA51
• Autostep function |
|
YOKOGAWA CLAMP-ON TESTER CL220 (AC/DC 300A)
• AC/DC current measurements with current ranges up to 300A |
|
YOKOGAWA GS820 MULTI CHANNEL SOURCE MEASURE UNIT
• DC voltage/current reference, pulse voltage/current source |