YOKOGAWA Clamp-on Power Meter CW10 (Single-Phase)

Code: YOKOGAWA CW10 (Single-Phase)


 

Datasheet PDF, 1.01 Mb

Description

The Clamp-on Power Meter CW10 (Single-Phase) is more like a tester type rather than a recorder, which can measure single phase AC and DC Power, Voltage, Currents, Power Factor, Frequency, Harmonics. It will also contribute to workers maintenance of not only consuming equipment but equipment for renewable energy such as solar and wind power generation.

 

Features:

  • AC / DC Power up to 600 kW, AC / DC Voltage max. 1000 V, AC / DC Current max. 600 A
  • True RMS for AC .
  • Harmonics 1st to 25th order
  • Power fluctuation using the ACA Inrush and Peak hold functions.
  • Frequency, Resistance, Continuity, Diode check, Power factor.
  • Up to 9999 counts, approx. 37mm max. diameter of measurable conductor (the jaw opens approx. 45mm max.)
  • CATIV 600V and CATIII 1000V compliant for safety.
  • Backlight on the display area turns on and a white LED automatically illuminates the front of jaw when clamping.
  • Non-contact Voltage Detection (Red LED lights up on detection).
  • Easy Operation with the Navigator key.
  • Low Pass Filter, Phase Detection, AC / DC Auto Sense.
 

More products YOKOGAWA

YOKOGAWA CLAMP-ON POWER METER CW10 (SINGLE-PHASE)

• AC / DC Power up to 600 kW, AC / DC Voltage max. 1000 V, AC / DC Current max. 600 A
• True RMS for AC .
• Harmonics 1st to 25th order
• Power fluctuation using the ACA Inrush and Peak hold functions.
• Frequency, Resistance, Continuity, Diode check, Power factor.

 

YOKOGAWA - MINI-MANOMETER MT10

• High reliability (with silicon resonant sensor)
• Compact
• Accuracy: ± (0.04% of rdg + 0.03% of F.S.) (130 kPa model)

 

YOKOGAWA - DL850E DL850EV SCOPECORDER

• Voltage & Currents
• Sensor Outputs
• Temperature, Vibration/Acceleration, Strain, Frequency
• Logic Signals & CAN / LIN and SENT

 

YOKOGAWA DIGITAL RESISTANCE METER 7556

• Wide operating rangeability (1 Ohm range to 100 M Ohm range)
• Full remote controlability via the standard RS232C serial, or optional GP-IB interfaces
• Software based calibration
• Printer output of measurement, and statistical analysis results

 

YOKOGAWA DIGITAL MULTIMETER TY520

• High Precision
• Basic accuracy 0.09%
• True RMS measurement
• Ensured Field Site Safety

 

YOKOGAWA CLAMP-ON TESTER CL220 (AC/DC 300A)

• AC/DC current measurements with current ranges up to 300A
• 24mm in diameter of measurable conductor
• Light weight & compact design
• Mean value display
• Sleep function

 

YOKOGAWA - PNEUMATIC PRESSURE STANDARD MC100

• Low temperature coefficient Zero point: ±0.003% of full scale/°C Span: ±0.002% of full scale/°C
• Divided output function with as many as 20 steps
• Auto-step output function
• Sweep output function

 

YOKOGAWA AQ1000 ENTRY LEVEL OPTICAL TIME DOMAIN REFLECTOMETER

• Wavelengths: 1310 / 1550 nm
• Dynamic ranges: 32 / 30 dB
• Size: 185 mm (W) × 116 mm (H) × 56 mm (D) ( 7.3" (W) × 4.6" (H) × 2.2" (D) )
• Weight: 660 g ( 1.46 Lbs )

 

YOKOGAWA AQ1200 COMPACT OPTICAL TIME DOMAIN REFLECTOMETER

• Applicable for installation and maintenance
• Models with a wavelength dedicated for maintenance of live fibers.
• These tri-wavelength models has two ports.

 

YOKOGAWA - DLM4000 MIXED SIGNAL OSCILLOSCOPES

• DLM4038 350MHz
• DLM4058 500MHz
• (Standard) 8 analog channels or 7 analog channels + 8 bit logic
• (/L16 option) 8 analog channels + 16 bit logic or 7 analog channels + 24 bit logic
• Motor control & inverter circuit development
• Reliable triggering
• Best in Class Deep Memory & Architecture
• Two fully independent zoom windows