YOKOGAWA Clamp-On Tester CL220 (AC/DC 300A)

Code: YOKOGAWA CL220


 

Datasheet PDF, 1.05 Mb

Description

Features:

  • AC/DC current measurements with current ranges up to 300A
  • 24mm in diameter of measurable conductor
  • Light weight & compact design
  • Mean value display
  • Sleep function
  • Approved for comformity to safety standards EN61010-1, EN61010-2-032 (CAT. III 300 V)

 

Description

AC/DC Mini Clamp-on

Method of detection

Mean Value

Display

LCD (Digital display: 3999 counts)

DC Current Range

40/300A

DC Current Resolution

0.01A

Response Time

Approx. 2 second

Range Switching

Auto-range

Data hold

On all range

Operating temperature and humidity

0 - 40°C, 90% RH or less (no condensation)

Influence of external magnetic field

1A or less at 400 A/m

Influence of conductor position

±(2% rdg + 5dgt) or less

Safety Standard

Conforms EN61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

300 Vrms or less

Withstanding voltage

3.7 kV AC for one minute

Power Supply

LR-44 x 2 (3V)
SR-44 x 2

Battery Life

Approx. 11 hours (continuous)

Consumed current

Approx. 9 mA

Sleep Function

Automatically powered down in about 5 minutes after the last switch operation

Diameter of measurable conductor

24 mm at maximum

Dimensions

Approx. 59 (W) x 147 (H) x 25 (D) mm

Weight

Approx. 100 g

Accessories

Batteries, carrying case (93033)
User's manual (IM CL235)

 

 

More products YOKOGAWA

YOKOGAWA - WT500 MID-RANGE POWER ANALYZER

• Current range: 0.5 to 40 A
• Voltage range: 15 to 1000 V
• Basic Power Accuracy: 0.1%
• frequency range: DC 0.5 Hz to 100 kHz

 

YOKOGAWA DIGITAL MULTIMETER TY720

• True RMS measurement
• New Functions for Electronic and Industrial Use
• Simultaneous measurement and display of DC and AC
• Switchable RMS/MEAN detection

 

YOKOGAWA - PNEUMATIC PRESSURE STANDARD MC100

• Low temperature coefficient Zero point: ±0.003% of full scale/°C Span: ±0.002% of full scale/°C
• Divided output function with as many as 20 steps
• Auto-step output function
• Sweep output function

 

YOKOGAWA DIGITAL MULTIMETER TY530

• Basic accuracy 0.09%
• True RMS measurement
• Ensured Field Site Safety
• Conforms to safety standards EN61010-1, 1000V CAT III, 600V CAT IV

 

YOKOGAWA AQ1200 COMPACT OPTICAL TIME DOMAIN REFLECTOMETER

• Applicable for installation and maintenance
• Models with a wavelength dedicated for maintenance of live fibers.
• These tri-wavelength models has two ports.

 

YOKOGAWA - LEAKAGE CURRENT TESTER 322610 (ANALOG)

• ± 2.5% full scale accuracy
• 100µA full scale value
• Shockproof indicator using taut band movement
• Built-in overload protection circuit
• Handy and easy to carry

 

YOKOGAWA - MINI CLAMP-ON TESTER CL120 (200A)

• Exclusive model for AC current measurement with current ranges up to 200A
• 24mm in diameter of measurable conductor
• Light weight & compact design
• Mean value display

 

YOKOGAWA DIGITAL INSULATION TESTER MY40

• 3 1/2-digit LCD;
• For each rating, you can save as many as 20 measurements at desired memory address numbers.
• Four AA (R6P) batteries the tester retains the measured resistance for approximately 5 seconds after the MEAS switch is turned off.

 

YOKOGAWA - DL850E DL850EV SCOPECORDER

• Voltage & Currents
• Sensor Outputs
• Temperature, Vibration/Acceleration, Strain, Frequency
• Logic Signals & CAN / LIN and SENT

 

YOKOGAWA 2560A HIGH VOLTAGE AND HIGH CURRENT PRECISION DC CALIBRATOR

• Wide output range of voltage and current generation
• Dials and switches for each digit and function
• High accuracy, stability, and resolution
• Various effective functions for analog meters calibration.