Molded Case Circuit Breaker Tester Vanguard MCCB-250

Code: Vanguard MCCB-250


 

Datasheet PDF, 0.35 Mb
   

Description

  • 250 Ampere current source
  • 4 current-source outputs (i.e., 5 A @ 120 Vac, 25 A @ 24 Vac, 120 A @ 6 Vac, 250 A @ 3 Vac)
  • 4-line by 20-character LCD display
  • Provides external current input (0-10 A)

 

 

The Vanguard MCCB-250 is a programmable, high-current source designed specifically for testing molded-case circuit breakers, thermal magnetic and solid-state overload motor-protection relays.

 

Built-in Timer

The MCCB-250’s built-in timer can test the

time-delay characteristics of protection relays

and molded-case circuit breakers. Once

the test is initiated, the current source and the

timer are automatically turned on at the next

zero-crossing point of the AC. The timer stops

when the MCCB-250 input detects a change

in the dry contact or voltage input, or detects

the removal of the test current. The test results

are then displayed in milliseconds and

fractions of cycle(s) on the unit’s back-lit LCD

screen (20 characters by 4 lines).

 

Current Source

The MCCB-250 has 4 current-source outputs

(5 A @ 120 Vac, 25 A @ 24 Vac, 120 A @ 6

Vac, 250 A @ 3 Vac) that conduct the test

current through the high-impedance load circuits.

Each current source can tolerate shortduration

over-loads up to 4 times the rated

current (1000 A max). This feature is used

for testing the instantaneous trip element of

molded-case circuit breakers. When using

this feature, the selected test current is displayed

on the LCD screen. When the MCCB-

250 is used as a current source, the currentfl

ow time (the current-on period) is displayed

 

External Current Input on the LCD screen.

The MCCB-250 also provides an external current

input (0 - 10 A). Both internal and external

current source readings can be viewed at

the same time.

 

Standard accessories

Part number MCCB-250 MCCB-250 and cables

Part number MCCB-250-CASE MCCB-250 shipping case

Part number MCCB-250-10FT MCCB-250 test leads - 10 foot

Part number MCCB-250-20FT MCCB-250 test leads - 20 foot

 

More products VANGUARD

EHV HIGH VOLTAGE CIRCUIT BREAKER ANALYZER VANGUARD DIGITMR PC

• dry-contact inputs 3 dry-contact channels
• timing windows 1 second, 10 seconds, or 20 seconds
• timing resolutions ±50 micro-seconds @ 1 sec. duration
• Inexpensive, PC-controlled EHV circuit breaker analyzer
• Optional "on-line" timing mode
• Small and light-weight
• Can test contact time, stroke, velocity, over-travel, and contact wipe

 

WINDING RESISTANCE OHMMETER FOR TESTING HIGH POWER INDUCTIVE TRANSFORMERS VANGUARD WRM-10P

• Range from 1 micro-ohm to 2,000 ohm
• Up to 10 Amperes of test current
• Auto discharge circuit for operator safety
• Built-in 2.5" Thermal Printer, computer interface
• Stores 48 records of 63 readings
• Weighs less than 27 lbs.

 

THREE-PHASE TRANSFORMER WINDING RESISTANCE METER VANGUARD TRM-20

• accurately measure resistance from 1 micro-ohm to 2000 Ohms
• Perform three phase test on a transformer without the need to switch cables
• Can provide individual Delta winding resistance values
• Can provide individual Wye (with no neutral) winding resistance values
• Demagnetize transformer after test
• Selectable test current from 1A to 20A
• Computer control via RS-232C, USB, or Bluetooth interface
• Built-in 2.5" wide thermal printer

 

CURRENT TRANSFORMER TEST SET TURN RATIO, EXCITATION CURVE , SATURATION GRAPHIC VANGUARD EZCT-2000C PLUS

• Performs CT excitation, current-ratio, polarity, and phase angle tests
• Measures insulation resistance and winding resistance of the CT seconday windings
• Measures the CT's secondary burden
• Test record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-comments
• Built-in 4.5-inch wide thermal printer
• Plot Multiple Saturation Curves
• Stores up to 128 CT test plans and 140 test records internally
• USB, Bluetooth, and USB Flash drive interface

 

600A AC PRIMARY CURRENT INJECTION SOURCE FOR RELAY TESTING VANGUARD PCI-600

• Results displayed on a 4-line by 20-character backlit LCD
• Test currents from 10 to 600 amperes AC
• Also has an external-current input (0-10 A)
• timer reading range 1 m.. 2 hours

 

PORTABLE RELAY TEST SET VANGUARD RFD-200

• Timer: 0 to 9.999 sec, 1 ms resolution; 10.00 to 99.99 sec, 10 ms resolution, 100.00 to 999.999 sec, 100 ms resolution
• built-in Timer displays contact time in both cycles and milliseconds
• AC current source with 3 outputs (10A, 40A, 100A)
• AC voltage source for testing relays up to 250 Vac
• DC Voltage source (0 - 300 Vdc)
• Volt meter input (0 - 600 V input range)
• Three power supplies (24 Vdc, 48 Vdc, 124 Vdc)
• Built-in power resistors

 

THREE-PHASE TRANSFORMER TURN RATIO TESTER VANGUARD ATRT-03

• Highest ratio: 0.8 - 15,000
• Built-in 4.5" thermal printer
• Excitation current measuring
• Phase angle measuring
• Computer interface
• Name-plate turns ratio calculation
• Computed % error based on measured and calculated ratio

 

THREE-PHASE TRANSFORMER TURN RATIO TESTER VANGUARD ATRT-03 S2

• Highest ratio: 0.8 - 15,000
• Capable of detecting 130 different 3-phase transformer types defined by ANSI, IEC, and Australian standards
• 3 Test voltages available: 8Vac, 40Vac, 100Vac
• Phase angle and excitation current measuring
• Computer Interface (RS-232C and USB Port)
• USB flash drive interface
• Name-plate turns ratio calculation
• Computed % error based on measured and calculated ratio
• Optional 4.5" thermal printer

 

CURRENT TRANSFORMER TEST SET TURN RATIO, EXCITATION, SATURATION, POLARITY VANGUARD EZCT-2000A

• Perform Saturation, Ratio and Polarity Tests
• Perform CT Winding Resistance Test
• Fully Automated
• Test record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-comments
• Plot Multiple Saturation Curves
• Store 140 Records (of 10 Saturation Curves)
• Computer Interface
• USB Flash drive interface

 

ON-LOAD TAP CHANGER ANALYZER AND WINDING RESISTANCE ANALYZER ON 3-PHASE TRANSFORMERS VANGUARD LTCA-40

• Auto discharge circuit for operator safety
• 3 resistance reading channels including one dynamic channel
• Digital resistance reading from 1 micro-ohm to 500 ohms
• 60Vdc power supply , outputting 40 amperes
• Calculate equivalent resistance value at reference temperature
• Stores 50 static records and 20 dynamic records
• Built-in 4.5-inch thermal printer