USB PC-based Oscilloscope 2 x 100 MHz Acute DS-1002 low cost cheap laptop notebook Scope virtual

    office@distek.ro     ROM     ENG  
Login | Create account | Forgot password?
Product cart  Products: 0 | Total: 0    
 
 
    Home |  About Us |  News |  Promotions |  Discounts |  Services |  Tech Library |  How to order? |  Sitemap |  Contact
 
 
Products         [+ Expand]   [- Colapse]

Oscilloscopes > ACUTE (6) > USB PC-based Oscilloscope 2 x 100 MHz Acute DS-1002

 


Products navigator [1] from [6]    ..
 

USB PC-based Oscilloscope 2 x 100 MHz Acute DS-1002

Code: Acute DS-1002
 
ACUTE
 
 Product Datasheet (*.PDF - 1.11 Mb)

» Technical Specs

  • PC-based
  • USB2.0 interface/powered
  • 2 channels (up to 6 channels)
  • Up to 200MS/s sampling (5GS/s Equivalent)
  • Up to 200MHz bandwidth
  • 64k/512k/2M points/channel
  • 20MHz bandwidth limitation
  • TV (DS-1002 N/A), Delay, External trigger
  • Scan line number (DS-1202, DS-1302 only)
  • 9 bits/CH vertical resolution, 2mV/DIV to 10V/DIV
  • RUN/STOP hardware button
  • Pass/Fail Hot Key Setting
  • FFT, Math, Save/Recall, Internet Control, etc.
  • Export data to WORD, EXCEL, TEXT, HTML, etc.
  • Data Logger (HD storage)

 

Automatic Measurements

Various measurement values can be determine easily in realtime and displayed. Both cursor measurements and direct measurement with corresponding displays are available.

 

Possible measurements include frequency, period, max., min., high, and low voltages, Vpp, amplitude, Vrms, average voltage, as well as duty cycles and pulse widths for positive and negative signals.

 

Mathematical Functions

The two channels can be linked through a variety of mathematical functions.

These channels can be added, subtracted, multiplied, and divided.

 

FFT (Fast Fourier Transformation)

The Acute software can use “Fast Fourier Transformation” to analyze the frequency components of the measurement signal and display them graphically. That makes this device the ideal choice for analyzing noise components in DC supplies and other harmonic components.

Supported scales: Linear RMS, dbV RMS, dBm RMS

Supported algorithms: Rectangle, Blackman, Hanning, Hamming, Harris, Triangular, Cosine, Lanczos and Gauss

 

Extended Configuration

The display and the device measurement behavior can be controlled through the extended configuration. As an example, the channel colors and the print settings can be changed. It is even possible to give the channels individual names which are then shown on screen so that it is really easy to relate the trace to the measurement signal.

 

Comprehensive Exporting Options

The recorded signal history can be exported to a large variety of file formats. This is especially useful for preparing reports, but the data can also be transferred as is for analysis in other programs. All settings can be saved in this manner as well.

Available formats: Hardcopy (direct printout), Word, Excel, CSV, Text, HTML and Screenshot in the intermediate clipboard.

 

Alarm Function for Triggering

The Acute DS-1202 can execute a program of choice for the first or every occurrence of a trigger event. This function is particularly useful for long term monitoring, where, as an example, a correctly set trigger could be used to detect faults and react accordingly.

 

Model

Sample Rate

Bandwidth

Memory Depth

Channel

Trigger

DS-1002

100MS/s

100MHz

64 K

2

-

DS-1102

200MS/s

200MHz

64 K

2

-

DS-1202

200MS/s

200MHz

512 K

2

NTSC, PAL, SECAM

DS-1302

200MS/s

200MHz

2 M

2

NTSC, PAL, SECAM

 

 

Pocket-DSO DS-1000 series Specifications

 

Specifications

DS-1302 DS-1202  DS-1102 DS-1002

Acquistion

Mode

Real-time sampling, Equivalent sampling, Roll mode, Average, Envelope

Input

Input Coupling

AC, DC, GND

Input Impedance

1MΩ±1% // 21pF±5%

Max. Input Voltage

42Vpk (DC + AC peak)

Vertical

Channel

DS-1002.DS-1102. DS-1202. DS-1302: allows to stack up to max. 6 channels

Vertical Resolution

9 bits /channel @ 5mV/DIV- 10V/DIV (8 bits @ 2mV/DIV)

Sensitivity

DS-1302.DS-1202.DS-1102: DC to 200MHz DS-1002: DC to 100MHz

Bandwidth

DC to 200MHz/DC to 200MHz/DC to 100MHz

BW Limit

Approx. 20MHz

Range

8 divisions

Offset Level

±4 divisions

Offset Increments

0.1 division

DC accuracy

±3%

Time Base

Sampling Rate

DS-1302.DS-1202.DS-1102: Real-time sampling: 200MS/s @ 1Ch, 100MS/s @2Ch
(Single Shot Equivalent sampling: 5GS/s (Repetitive)
DS-1002: Real-time sampling: 100MS/s @ 1Ch, 50MS/
s @2Ch (Single Shot Equivalent sampling: 2.5GS/s (Repetitive)

Time Base Range

2ns/DIV to 10s/DIV (as 2- 5-10 step)

Accuracy

100ppm

Range

10 Divisions

Pre/Post Trigger

+/-64k points

Time Resolution

200ps

Record Length

DS-1102.DS-1002: 2k points/channel to 64k points/channel
DS-1202: 2k points/channel to 512k points/channel
DS-1302: 2k points/channel to 2m points/channel
ROLL mode: 32k points/channel (Log Length = Hard Disk limitation)

Trigger

Type

DS-1302.DS-1202.DS-1102: Rising, Falling, Delay-Trigger, TV-Trigger
DS-1002: no TV Trigger)

Mode

Auto, Normal and Single
(With RUN/STOP hardware button on the DSO device)

Source

CH1, CH2, Ext-Trig

Coupling

DC, HF rejection

Sensitivity

DC to 25MHz = 0.35div or 3.5mv;
25MHz to Max. = 1.5div or 15mv

Trigger Level

±4 divisions

Trigger Increments

0.1 division

Measurement and Processing

Special function

Autoset, Monitor from Internet (TCP/IP)

Measurement

Vp-p, Vmax, Vmin, Vamp, Vtop, Vbase, Vupper, Vmiddle, Vlower,
Vmean, Vrms, Positive overshoot, Negative overshoot, Period,
Frequency, Pulse width

Cursor

Time difference, Voltage difference

Math

Add, Sub, Multiplication, Division

FFT

Rectangular (Vertical scale: dbV RMS, Linear RMS)

Export Data

WORD, EXCEL, CSV, TEXT, HTML, Clipboard, Hardcopy, Preview

Trigger Input/Output

EXT-TRIG Input Limitation

TTL Level

EXT-TRIG Acknowledge Level

1.6V to 5V, rising/falling edge

EXT-TRIG Acknowledge Freq.

">10ns" and ">0.1 TIME/DIV"

TRIG-OUT

3.3v pulse, 20ns delay after trigger occurring
(only for DS-1202 stack function)

Calibration Output

Level

Approx. 3.3V

Frequency

1kHz ±0.5%

Environment

Operation

0 to +50

Storage

-10 to +60

Physical

Interface

USB2.0 (USB1.1 compatible)

Power

USB2.0 (USB1.1 compatible)

Dimension (device only)

135/80/26 mm3

Weight (device only)

230 g

Accessories

Probes

DS-1302.DS-1202.DS-1102: 250MHz probe (1x/10x) x2
DS-1002: 100MHz probe (1x/10x) x2

Others

Installation CD, USB2.0 cable, User manual, Soft case

 

 

DS-1000 Spec. Limitations in Stack Model

 

Acquistion

Mode

Real-time sampling, Average, Envelope .
Equivalent sampling and Roll mode only available in Master-DSO

Time Base

Sampling Rate

Real-time sampling: 200MS/s @ 1Ch/DSO, 100MS/s @ 2Ch/DSO
Equivalent sampling: 5GS/s only for Master-DSO

Time Base Range

2ns/DIV to 100ms/DIV (as 2- 5-10 step) for Master and Slave DSOs
200ms/DIV to 10s/DIV (Roll mode) only for Master-DSO

Trigger

Source

CH1, CH2, Ext-Trig in Master-DSO (NA for Slave-DSO)

Jitter

+/- 200ps in Master-DSO; +/-10ns in Slave-DSO

 

 

DS-1000 series System Requirements
 

1. INTEL Pentium 300M CPU or compatible PC (2G recommended)
2. One USB port (USB2.0 recommended)
3. Windows 98/ME/2000/XP/2003/Vista/7 operating system
4. 128M bytes memory (512M recommended)
5. Disk space more than 10M bytes
6. One CD-ROM drive for installation
7. 640x480 VGA or higher (1280x1024 recommended)
8. 101-Keys keyboard
9. Mouse (with wheel recommended)



» Standard included accessories

Packing List of DS-1000 series DS-1002/DS-1102/DS-1202/DS-1302

 

Pocket DSO device
1
250MHz probes (with 1x/10x switch)
2*
Probe accessories pack
2
Stack function cable
1
USB2.0 1.8m cable
1
Installation CD
1
User manual
1
DSO soft case
1

 

 

 

Home |  About Us |  News |  Promotions |  Discounts |  Services |  Tech Library |  Terms and Conditions |  How to order? |  Useful links |  Sitemap |  Contact |  Politica Cookie

        
Copyright © 2010 - 2024 / Distek

Product: USB PC-based Oscilloscope 2 x 100 MHz Acute DS-1002 low cost cheap laptop notebook Scope virtual