Tekbox TBOH01 5UH Line Impedance Stabilisation Network LISN – CISPR 25

    office@distek.ro     ROM     ENG  
Login | Create account | Forgot password?
Product cart  Products: 0 | Total: 0    
 
 
    Home |  About Us |  News |  Promotions |  Discounts |  Services |  Tech Library |  How to order? |  Sitemap |  Contact
 
 
Products         [+ Expand]   [- Colapse]

Oscilloscopes > Megger (209) > Tekbox TBOH01 5UH Line Impedance Stabilisation Network LISN – CISPR 25

 


  ..  Products navigator [84] from [209]    ..
 

Tekbox TBOH01 5UH Line Impedance Stabilisation Network LISN – CISPR 25



Recommended products

Tekbox TBPS01 EMC Near-field Probes + TBWA2 Wideband Amplifier




 

Tekbox TBOH01 5UH Line Impedance Stabilisation Network LISN – CISPR 25

Code: Tekbox TBOH01 5UH
 
Tekbox Digital Solutions
 
 Product Datasheet (*.PDF - 1.45 Mb)

» Technical Specs

The TBOH01 5uH LISN is a device required to setup conducted noise measurements of DC-powered devices.

 

It is designed to be used for EMC pre-testing in the frequency range of 150kHz to 110 MHz.

The LISN is inserted into the supply line of the DUT (Device Under Test). Conducted noise which is present at the supply terminals of the DUT can be measured at the BNC connector using a spectrum analyzer or a measurement receiver.

 

The source (supply) terminal and the DUT terminal are decoupled by a 5µH inductor.

 

Features:

  • Frequency range: 100kHz – 110MHz (1GHz, see figure 4 in the manual)
  • DC Resistance: 40 mΩ
  • Maximum current: 10A
  • Nominal operating voltage range: 0 – 60V DC *
 

Home |  About Us |  News |  Promotions |  Discounts |  Services |  Tech Library |  Terms and Conditions |  How to order? |  Useful links |  Sitemap |  Contact |  Politica Cookie

        