Code: Testec TT-SI9010, TT-SI9010A
Description
TT-SI 9010 1:100 / 1:1000, 70MHz
Bandwidth: 70MHz
Attenuation Ratio: x100/x1000
Accuracy: +/-2%
Rise Time: 5ns
Input Impedance: 10Ω, 10pF
Only connect to a grounded oscilloscope!
Input Voltage
Differential Mode: +-700V / +-7000V
Common Mode: +-7000V
Absolute max. Voltage: 2500Vrms
TT-SI 9010A 1:100 / 1:1000, 70MHz
Bandwidth: 70MHz
Attenuation Ratio: x100/x1000
Accuracy: +/-2%
Rise Time: 5ns
Input Impedance: 10Ω, 10pF
Only connect to a grounded oscilloscope!
Input Voltage
Differential Mode: +-700V / +-7000V
Common Mode: +-7000V
Absolute max. Voltage: 5000Vrms
Power requirements: 4x AA Cells or Mains Adaptor 6VDC/200mA or regulated 9VDC/120mA
Dimensions (LxWxH): 202 mm x 83 mm x 38 mm
Length: BNC Cable 90 cm - Input Leads 60 cm
Weight: 500 g (including 4 cells)
More products TESTEC
|
KELVIN TEST LEAD TESTEC TT-20000
• TT-22000 Connector: 5 Pin DIN-Plug |
|
VOLTAGE OSCILLOSCOPE PROBE 1X/10X ATTENUATION TESTEC TT-HF300
• TT-HF 312 1:1/10:1 - 1,2m, 30MHz/300MHz |
|
HIGH VOLTAGE OSCILLOSCOPE PROBE 100X ATTENUATION TESTEC TT-HV
• TT-HV 150 100:1, 300MHz |
|
HIGH VOLTAGE OSCILLOSCOPE PROBE 15KV TESTEC TT-HVP 15HF
• TT-HVP 15HF 1000:1, 50MHz |
|
PASSIVE OSCILLOSCOPE PROBE 1X ATTENUATION TESTEC TT-MF100
• TT-MF 112 1:1 - 1,2m, 30MHz |
|
SAFETY ISOLATED HIGH VOLTAGE OSCILLOSCOPE PROBE CAT TESTEC TT-SP
• TT-SP 101 1:1 - 1,2m, 45MHz |
|
HIGH VOLTAGE OSCILLOSCOPE PROBE 40KV TESTEC TT-HVP40
• TT-HVP 40 1000:1, 300Hz |
|
PASSIVE OSCILLOSCOPE PROBE 10X ATTENUATION TESTEC TT-LF200
• TT-LF 212 10:1 - 1,2m, 150MHz |
|
HIGH VOLTAGE ACTIVE DIFFERENTIAL PROBE FOR OSCILLOSCOPES 70MHZ TESTEC TT-SI9010
• TT-SI 9010 1:100 / 1:1000, 70MHz |
|
PASSIVE OSCILLOSCOPE PROBE 1X/10X ATTENUATION TESTEC TT-MF300
• TT-MF 312 1:1/10:1 1,2m, 20MHz/250MHz |