Seba KMT ESG NT Pinpointing Earth Fault Locator in sheath of underground cables

Code: Seba-KMT ESG-NT


 

Datasheet PDF, 0.45 Mb
       

Description

ESG NT

The earth fault locator ESG NT is used for the high accuracy pinpointing of a sheath fault. State of the art technology in connection with a bright, sun readable TFT color Display allows an very easy use. 

The display happens by a bargraph, similar to the analogue display or by a history display, which shows the deflections of the last 7 pulses. A fully automatic calibration keeps the display always at zero and the integrated noise suppression eliminates all influences by DC, Railway currents, industrial plants and high resistive soil environment. By two earth rods, the ground step voltage potential is measured and the direction towards the fault is indicated by the display. 

Key benefits:

  • Automatic adaptation to voltage level
  • Automatic filtration of interfering signals
  • Automatic zero calibration, no adjustments necessary
  • History mode
  • High-contrast color display

 

As source for the exact pinpointing with the ESG NT the following equipment is available:

  • BT 500 IS-1
  • MMG 10
  • MFM 10
  • and all other SebaKMT systems with pulsed output voltage for sheath fault pinpoint location

The ESG NT is also available as combination set with the digiPHONE+ in one unit.

 

  • All advantages at a glance
  • Automatic suppression of external potentials
  • Automatic adaptation to the voltage level
  • Automatic detection of the pulse rate
  • Automatic zero adjustment
  • Very high measuring sensitivity in the µV range
  • Very easy operation
  • Cable mounting at the dividable insulated earth rod
 

Standard accessories

Receiver ESG NT

2 earth rods

2 connection cables

1 set of batteries

Manual

 

Recommended options

Options

A-Frame

Vehicle Mounting

 

More products SEBAKMT

SEBA KMT PD SURVEYOR AIR PARTIAL DISCHARGE DETECTOR FOR MEDIUM VOLTAGE CABLES, SWITCHGEAR, PLANTS

• Three PD sensor technologies in one device
•  Early detection of PD activity
•  Universal application - can be applied to
• MV cables, MV switchgear & other types of MV plants
•  Directs maintenance resources straight to the problem areas
•  Easy to use

 

SEBA KMT SEBALOG N-3 AUTOMATIC WATER LEAK LOCATION WITH CORRELATING NOISE LOGGER NETWORK

• Latest measured data available every day
• Correlation function
• No time-consuming driving past individual loggers
• Remote configuration
• Very simple installation process
• Cost-effective data transmission

 

SEBA KMT VFL CR-80 46KV HIGH VOLTAGE CABLE TEST SYSTEMS

• Powerful 0.1 Hz VLF test system
• High test power without frequency reduction
• No polarisation effects as by DC testing
• Protocoling
• Breakdown recognition
• Leakage current measurement

 

SEBA KMT VFL SINUS 34KV 0.1HZ SINE WAVE CABLE TEST SYSTEMS

• High test capacity of 5 µF
• Suitable for outdoor use (IP 54)
• Single-button operation easyGO
• Integrated safety system
• Reporting
• Continuous duty cycle

 

SEBA KMT GEOLUX GL 660-1 EARTH FAULT LOCATOR FOR FAULT LOCATION IN ISOLATED, EARTH FREE SYSTEMS

• Earth fault locator for fault location in isolated, earth free systems
• Mains filter for direct coupling to live cables up to 660 V
• Pulsed output current for easier detection of the test signal
• Filter for the suppression large interference signals
• Location of earth faults up to 150 kOhm
• No switch off during the fault location required
• No influence to the signal lines connected to

 

SEBA KMT MMG 10 CABLE SHEATH TESTER

• Adjustable current limiter
• Easy and powerful testing of cable jackets
• Pulsed output voltage for sheath fault pinpointing
• Burning of cable faults

 

SEBA DIGIPHONE+ ESG NT PINPOINTING ACOUSTIC PINPOINTING SET FOR STEATH FAULT LOCATION IN UNDERGROUND CABLES

• Perfect acoustic quality and noise immunity
• Automatic filtration of interfering signals
• Automatic zero calibration, no adjustments necessary
• History mode
• Acoustic and step voltage fault location in one device
• BNR technology for perfect acoustic quality and noise immunity
• Automatic filtration of interfering signals
• Automatic setting of all parameters, no adjustments necessary

 

SEBA KMT FERROLUX FLE 10 AUDIO FREQUENCY RECEIVER FOR CABLE LOCATION, SELECTION, SHEATH FAULTS

• Precise direction guidance with right/left arrows
• "SignalSelect" for clear route location
• Depth and signal current intensity measurement at the push of a button
• Route sensor weighs less than 1 kg for non-tiring use
• "DirectSignal" for effective line location

 

SEBA KMT MFM 10 CABLE STEATH FAULT LOCATION SYSTEM

• Testing, prelocation and pinpointing of sheath faults
• Voltage up to ±10 kV DC
• High current of up to 750 mA
• Only one HV connection cable
• Automatic measurement and protocolling

 

SEBA KMT HPA35 HPA50 HPA58 HPA78 AC HIGH VOLTAGE HIPOT TESTING WITHSTANDING

• HPA 35, AC testing up to 35 kVrms
• HPA 50 / 58 AC testing up to 50 / 58 kVrms
• HPA 78, AC testing up to 78 kVrms