Brand: Micronix

Electromagnetic Anechoic Box Micronix Taurus MY1510/ MY1520/ MY1530

Code: Micronix Taurus MY1510/ MY1520/ MY1530


 

Datasheet PDF, 0.49 Mb
     

Description

  • High quality and reliability the testing and measuring instruments manufacturer offers
  • Good cost-performance and short delivery time
  • The electromagnetic anechoic box that covers the inside of the shield box with an radio wave absorber

Model MY1510
Outside dimensions
Inside dimensions
Weight approx.
Shielding characteristics
Reflection loss
Connectors
I/F Module installation capacity
Small size : Portable and light weight type
380 W×380 D×165 H mm
315 W×315 D×100 H mm
3.5kg (without I/F Module)
more than 60dB @ 2 .4GHz
more than 20dB @  2.4GHz, MYA-75
2 pcs of SMA @ back
1 module @ back

 

Model MY1520

Outside dimensions

Inside dimensions
Weight approx.
Shielding characteristics
Reflection loss
Connectors
I/F Module installation capacity
Medium size :
The most general and universal type
520(W)×520(D)×520(H)mm
460(W)×460(D)×460(H)mm
15kg (without I/F Module)
more than 60dB @ 2.4GHz
more than 20dB @ ? 2.4GHz, MYA-75
2pcs of SMA @ back
2 modules @ back

 

Model MY1530

Outside dimensions

Inside dimensions
Weight approx.
Shielding characteristics
Reflection loss
Connectors

I/F Module installation capacity

Large size :

Type corresponding to even big EUT
1120(W)×620(D)×705(H)mm
1000(W)×500(D)×500(H)mm
56kg (without I/F Module)
more than 60dB @ 2.4GHz
more than 20dB @ ? 1.2GHz, MYA-77
4 pcs of SMA @ 2 at back and each one at both sides
4 modules @ back

 

Recommended options

Small size (MY1510)
I/F Module
Medium size (MY1520)
I/F Module
Wooden table
Radio wave absorber(MYA-77)
Radio wave absorber(MYA-79)
Large size (MY1530)
I/F Module
Wooden table
Turn table unit
Radio wave absorber(MYA-75)
Radio wave absorber(MYA-79)

 

The I/F module is a module on which AC supply, DC supply, LAN, USB, SMA, BNC, N, Triaxial and/or D-sub connectors are mounted. All of the I/F modules are common to Taurus series.

 

Option

Mounted connectors

IFM1

IFM1 AC(1pc), LAN(1pc), USB(1pc), D-sub9pin(1pc)

IFM2

IFM2 AC(1pc), LAN(2pcs), USB(2pcs), D-sub9pin(1pc)

IFM3

AC(1pc), LAN(2pcs), USB(2pcs), D-sub25pin(1pc)

IFM4

DC(1pc), LAN(1pc), USB(1pc), D-sub9pin(1pc), D-sub25pin(1pc)

IFM5

SMA(2pcs), BNC(2pcs), N(2pcs), Triaxial(2pcs)

 

More products MICRONIX

ELECTROMAGNETIC SHIELDING ANECHOIC BOX FOR EMI TESTING MICRONIX MY5310/ MY5410

• These two models using the ferrite tile as the radio wave absorber are optimum for EMI test
• The compact and broadband antenna by our own development is prepared as option
• Capable of EMI test in frequency range 30MHz to 3GHz if upgraded to MR2300 system

 

EMS TESTING SYSTEM MICRONIX MR2350

• The electric field strength of 1, 3, 10V/m
• The malfunction of the EUT by the electromagnetic radiation can be observed
• One PC controls all of applications such as the EMI test, the EMS test, the EUT camera monitor and the electric turntable (option)

 

INDUSTRIAL ANECHOIC SHIELD BOX FOR MASS PRODUCTION MICRONIX MY5220

• Newest type of anechoic box with high shielding characteristics
• Optimum for mass production line needing a large opening

 

ELECTROMAGNETIC ANECHOIC BOX MICRONIX TAURUS MY1510/ MY1520/ MY1530

• High quality and reliability the testing and measuring instruments manufacturer offers
• Good cost-performance and short delivery time
• The electromagnetic anechoic box that covers the inside of the shield box with an radio wave absorber

 

SHIELDED ANECHOIC BOX FOR TESTING WIRELESS, CDMA, GSM MICRONIX ME8661A

• Optimum for testing W-CDMA, CDMA, GSM, PDC, PHS, ETC and wireless systems
• A receiving antenna of your choice will be mounted
• simple type shielding box that may be used on a desk
• triple structure, i.e., radio wave absorber, copper plate and aluminum plate
• covers the frequency band of low frequency through 18GHz
• acrylic resin table for placing a test sample is provided, and this structure permits easy mounting of an optional receiving antenna

 

EMC EMI EMS TESTING SYSTEM MICRONIX MR2300

• The first EMI total test system in the world
• Compact and broadband antenna by our own development
• Small and large anechoic boxes
• Calibration of the entire system
• Conformity to regional and international standards
• Low system price

 

SHIELDING BOX WITH CONVEYER FOR MASS PRODUCTION LINES MICRONIX ME8668

• A model equiping with automatic conveyer for mass production line.
• Outside dimensions : 922 (W) × 794 (H) × 731 (D) mm
• Inside dimensions : 801 (W) × 610 (H) × 610 (D) mm
• Weight : approx. 94kg (include automatic conveyer)
• Capable of customizing

 

LINE IMPEDANCE STABILIZATION NETWORK MICRONIX MPW201

• The conducted emission discharged through the power supply line is measured by using the line impedance stabilization network (LISN).
• To measure the disturbance noise with reproducibility, the LISN, which makes constant the impedance of the power source observed from EUT, is inserted in the power supply line.
• The output impedance of the disturbance noise to be measured is 50 ohms.

 

ELECTROMAGNETIC ANECHOIC BOX AIR FAN COOLED MICRONIX MY1515

• Type equipping with exhaust fan and intake
• As the temperature rise in box is suppressed, the ideal test environment is provided even during long time operation

 

PROGRAMMABLE VARIABLE ATTENUATOR MICRONIX MAP800/ MAP810/ MAP850

• The frequency range is so wide as 300MHz to 6.6GHz
• The minimum step size of attenuation is 0.05dB
• maximum attenuation is 80dB