Brand: Micronix

Electromagnetic Anechoic Box Micronix Taurus MY1510/ MY1520/ MY1530

Code: Micronix Taurus MY1510/ MY1520/ MY1530


 

Datasheet PDF, 0.49 Mb
     

Description

  • High quality and reliability the testing and measuring instruments manufacturer offers
  • Good cost-performance and short delivery time
  • The electromagnetic anechoic box that covers the inside of the shield box with an radio wave absorber

Model MY1510
Outside dimensions
Inside dimensions
Weight approx.
Shielding characteristics
Reflection loss
Connectors
I/F Module installation capacity
Small size : Portable and light weight type
380 W×380 D×165 H mm
315 W×315 D×100 H mm
3.5kg (without I/F Module)
more than 60dB @ 2 .4GHz
more than 20dB @  2.4GHz, MYA-75
2 pcs of SMA @ back
1 module @ back

 

Model MY1520

Outside dimensions

Inside dimensions
Weight approx.
Shielding characteristics
Reflection loss
Connectors
I/F Module installation capacity
Medium size :
The most general and universal type
520(W)×520(D)×520(H)mm
460(W)×460(D)×460(H)mm
15kg (without I/F Module)
more than 60dB @ 2.4GHz
more than 20dB @ ? 2.4GHz, MYA-75
2pcs of SMA @ back
2 modules @ back

 

Model MY1530

Outside dimensions

Inside dimensions
Weight approx.
Shielding characteristics
Reflection loss
Connectors

I/F Module installation capacity

Large size :

Type corresponding to even big EUT
1120(W)×620(D)×705(H)mm
1000(W)×500(D)×500(H)mm
56kg (without I/F Module)
more than 60dB @ 2.4GHz
more than 20dB @ ? 1.2GHz, MYA-77
4 pcs of SMA @ 2 at back and each one at both sides
4 modules @ back

 

Recommended options

Small size (MY1510)
I/F Module
Medium size (MY1520)
I/F Module
Wooden table
Radio wave absorber(MYA-77)
Radio wave absorber(MYA-79)
Large size (MY1530)
I/F Module
Wooden table
Turn table unit
Radio wave absorber(MYA-75)
Radio wave absorber(MYA-79)

 

The I/F module is a module on which AC supply, DC supply, LAN, USB, SMA, BNC, N, Triaxial and/or D-sub connectors are mounted. All of the I/F modules are common to Taurus series.

 

Option

Mounted connectors

IFM1

IFM1 AC(1pc), LAN(1pc), USB(1pc), D-sub9pin(1pc)

IFM2

IFM2 AC(1pc), LAN(2pcs), USB(2pcs), D-sub9pin(1pc)

IFM3

AC(1pc), LAN(2pcs), USB(2pcs), D-sub25pin(1pc)

IFM4

DC(1pc), LAN(1pc), USB(1pc), D-sub9pin(1pc), D-sub25pin(1pc)

IFM5

SMA(2pcs), BNC(2pcs), N(2pcs), Triaxial(2pcs)

 

More products MICRONIX

EMC EMI EMS TESTING SYSTEM MICRONIX MR2300

• The first EMI total test system in the world
• Compact and broadband antenna by our own development
• Small and large anechoic boxes
• Calibration of the entire system
• Conformity to regional and international standards
• Low system price

 

SHIELDED ANECHOIC BOX WITH ABSORBER FOR GSM TEST MICRONIX M8661B

• Equipped with the radio wave absorber covering 800MHz/900MHz frequency band
• Optimum for wireless system test for technical standard, receiving sensitivity test and simple
• EMC test of a wide frequency band

 

ELECTROMAGNETIC ANECHOIC SHILEDED BOX FOR EMC TEST MICRONIX MY5305

• Compact size with ferrite absorber
• Optimum for EMC test, receiving sensitivity test and wireless system test for technical regulations

 

ELECTROMAGNETIC ANECHOIC BOX MICRONIX TAURUS-N MY1510N/ MY1520N/ MY1530N

• High quality and reliability the testing and measuring instruments manufacturer offers
• Good cost-performance and short delivery time
• The electromagnetic anechoic box that covers the inside of the shield box with an radio wave absorber

 

LINE IMPEDANCE STABILIZATION NETWORK MICRONIX MPW201

• The conducted emission discharged through the power supply line is measured by using the line impedance stabilization network (LISN).
• To measure the disturbance noise with reproducibility, the LISN, which makes constant the impedance of the power source observed from EUT, is inserted in the power supply line.
• The output impedance of the disturbance noise to be measured is 50 ohms.

 

EMS TESTING SYSTEM MICRONIX MR2350

• The electric field strength of 1, 3, 10V/m
• The malfunction of the EUT by the electromagnetic radiation can be observed
• One PC controls all of applications such as the EMI test, the EMS test, the EUT camera monitor and the electric turntable (option)

 

HANDHELD SPECTRUM ANALYZER 50 KHZ..3.3 GHZ/ 8.5 GHZ MICRONIX MSA300

• 50kHz …3.3 GHz Frequency Range(model MSA338)
• 50kHz …8.5 GHz Frequency Range(model MSA358)
• Average noise level -117dBm
• 150 minutes battery operation
• Easy operation by AUTO mode
• Measuring electric field strength from 300MHz to 6.2GHz

 

HANDHELD SPECTRUM ANALYZER 50 KHZ..3.3 GHZ/ 8.5 GHZ MICRONIX MSA300

• 50kHz …3.3 GHz Frequency Range(model MSA438)
• 50kHz …8.5 GHz Frequency Range(model MSA458)
• Compact and lightweight 1.8kg
• Large and color TFT display 5.7 inches, 640x480 dots and color LCD
• 
• Four hours battery operation
• USB memory & communication
• Average noise level -127dBm

 

INDUSTRIAL ANECHOIC SHIELD BOX FOR MASS PRODUCTION MICRONIX MY5220

• Newest type of anechoic box with high shielding characteristics
• Optimum for mass production line needing a large opening

 

ELECTROMAGNETIC ANECHOIC BOX MICRONIX TAURUS MY1510/ MY1520/ MY1530

• High quality and reliability the testing and measuring instruments manufacturer offers
• Good cost-performance and short delivery time
• The electromagnetic anechoic box that covers the inside of the shield box with an radio wave absorber