Megger BGFT 246100B Battery Ground Fault Tracer

Code: Megger BGFT 246100B


 

Datasheet PDF, 0.52 Mb

Description

• Ground faults in ungrounded dc battery systems easily located 
• Operates in high electrical noise environment 
• Simplifies fault tracing by identifying fault characteristic (resistive and capacitive) magnitudes 

 

The Battery Ground-Fault Tracer is an economical, manually-balanced instrument that identifies, tracks and locates ground faults in ungrounded dc battery systems - on-line. It is particularly effective in a high electrical noise environments, as the strength of the test current can be adjusted.

The Battery Ground-Fault Tracer accelerates fault location by eliminating trial-and-error procedures and because faults can be located without going off-line. It is particularly useful in any industry where supply of power for operating measurement, communication and control equipment is critical.

 

Standard accessories

Battery Ground Fault Tracer,120/240 V ac, 50/60 Hz, CE-marked 246100B

Included Accessories

Fused source leads, 20 ft (6 m) [1 pr] 29386-3

Current transformer, 2 in. (5 cm) with leads, 4 ft (1.2 mm) [1 pr] 29999-1

AC power cord, 6 ft (1.8 m) [1] 17032-7

Feedback cable, 40 ft (12 m) [1] 29998

Padded accessory bag [1] 29996

Battery, 9 volt [1] 1482-1

Operator’s manual [1] AVTM246100B

                                      

Optional Accessories

Mini-CT, 0.5 in. (12 mm) with 4.25 ft (1.3 m) lead 30595

 

Recommended options

 

 

More products MEGGER

STATIC / DYNAMIC RESISTANCE MEASUREMENT ACCESSORY FOR EGIL MEGGER - SDRM201

• Enables resistance measurement on circuit breakers
• Small and light weight
• A number of operations can be run with short waiting intervals

 

FREQUENCY RESPONSE ANALYZER MEGGER FRAX200 FRAX150 FOR POWER TRANSFORMER

• High dynamic range and accuracy
• Easy-to-use support software with advanced analysis tools
• Smallest SFRA instrument in the industry
• Hardware designed to ensure repeatable connections
• Fulfils international standards for SFRA

 

MEGGER TM1800 CIRCUIT BREAKER ANALYZER CG-19290 CG-19292 CG-19294 CG-19296

• Modular based design - user configurable TM1800 from nine different modules
• Built in PC with CABA Local software - advanced testing with predefined breaker test plans (templates), onsite measurement view and analysis
• Dual ground testing using DCM module - increased safety with both sides of breaker grounded
• Fast and easy testing - Select-Connect-Inspect workflow and high level user interface
• Graphical results for quick interpretation - timing and motion measurements, coil currents
• USB and Ethernet communication interface - for quick back up, LAN connection and printer options
• CABA Win - for advanced data analysis, database interface and common test data archive

 

MEGGER TDR900 TIME DOMAIN REFLECTOMETER & CABLE LENGTH METER

• Full autoranging for measuring the length of power, telephony, CATV and LAN cables, provides distance to an open or short.
• Extra large, high resolution backlit LCD.
• Automatic output impedance control of 25, 50, 75, 100, 125 or 150 ohms.
• User-friendly menu on screen operation.
• Cable length calibration function.
• Internal library of 39 standard cable types.

 

MEGGER SVERKER 750 780 PROGRAMMA SINGLE PHASE RELAY TESTER

• The engineer’s toolbox for all single phase relay testing!
• Stand-alone functionality
• Rugged and reliable for field use

 

SMART PRIMARY INJECTION TEST SYSTEM MEGGER SPI225

• Up to 2000A output
• Smallest primary injection test system in its class
• First unit on the market to eliminate variac control
• Output current regulation
• Designed for switchgear commissioning, circuit breaker, CT commissioning, ground grid and relay testing
• Software includes thousands of circuit breaker TCC curves

 

MEGGER OTS60PB OTS80PB OIL BREAKDOWN TESTER 60KV 80KV

• portable 60 kV and 80 kV oil test sets
• Lightest - miniumum weight 16 kg
• Lock in precision - oil vessel with lockable adjustment
• Bright 3.5 inch colour display visable out doors
• Suitable for mineral, ester and silicon oils
• Trip detection circuit with direct measure ment of voltage and current
• Ultra fast (<10 µs) HV switch off time

 

MEGGER FREJA 306 PROGRAMMA RELAY TESTER CF-29091

• current outputs, higher amps (3 x 15 A + 3 x 35 A), VA or compliance voltage.
• test differential relays with 6 currents, or virtually any single or 3-phase relay
• For secondary testing of protection relays
• Can be used stand-alone or with a PC
• Flexble, can test many relay types
• Lightweight and portable
• Greatest possible precision

 

BOND TESTER MEGGER - BT51

• High test current
• Four terminal measurement
• Two measuring ranges (2000 mO. and 20,00 mO.)and maximum resolution of 0,01 mO.
• Protected against inadvertent connection to the mains supply

 

MEGGER DLRO10X RESISTANCE OHMMETER DLRO 10 DLRO 10X 6111-428 6111-429

• up to 10A current
• Accurate results in under three seconds
• Auto current reversal cancels standing emfs
• Fuse protected to 600 V
• NiMH battery reduces weight
• 250 mW power limit (with optional override) to avoid heating the test sample