High Precision Universal Calibrator Meatest M142i

Code: Meatest M142i


 

Datasheet PDF, 0.06 Mb

Description

  • 15ppm Accuracy
  • DC/AC voltage up to 1000 V
  • DC/AC current up to 30 A
  • TC temperature sensors simulation
  • RS232 interface

 

Description

Multifunction calibrator M142i is calibrator of electric quantities for application in calibration laboratories and in production lines where meters are manufatured. It can be used for calibration and adjustment of meters from the field of voltage and current. M142i is economy version of M142 model and contains only voltage and current outputs.

M142i multifunction calibrator is available in bench-top and in 19" rack housings.

 

Basic parameters

Basic function of the calibrator is generating of the calibrated DC/AC voltage in the range from 0 V to 1000 V and DC/AC current in the range from 0 A to 30 A . Using a 50-turn coil the current range can be extended to 1500 A. The best accuracy of the calibrator on DC voltage ranges is 15 ppm, on AC voltage ranges 250 ppm, on DC current ranges 130 ppm and on AC current ranges 550 ppm. Maximum frequency range is from 20 Hz to 100 kHz for harmonic output waveform.

For calibrations of the thermometers and temperature regulators, the function of simulation of temperature sensors is determined. Calibrator is able to simulate all common used TC sensors of the R, S, B, J, T, E, K and N types as well. Compensation of the TC cold junction is made either by entering value from the keyboard. The precision of the simulated resistance and TC sensors depends on set value and type of the sensor.

 

User comfort

M142 Calibrator is equipped with a number of other functions which make its use easier. Among them belong possibility to set relative deviations from the actual value of the selected output signal, displaying of the output signal uncertainty, internal calibration procedure and others. Concept of the calibrator's control and indication uses a large area luminescence display on which all necessary information is concentrated. The control is perform by selection from the menu. Moreover, frequently used functions have firmly assigned keys with direct control. The calibrator is equipped with RS232 serial port making it possible to be controlled by personal computer.

The calibrator can be included into MEATEST WinQbase/Caliber software calibration systems.

 

Standard accessories

  • Power line cable 1 pc
  • Operation manual 1 pc
  • Option 10/11 : Test cable for 1000V - 20 A, black/red 2 pcs
 

Recommended options

  • Option 130-50 Current coil with 50 turns. Suitable for clamp A-meters testing up to 500 A. Maximal recommended outpu current into the coil is 10 A.
  • Option 10 Test cable 20A/1000V (black)
  • Option 11 Test cable 20A/1000V (red)
  • Option 20 Test cable BNC/BNC 1m
  • Option 30 Test cable BNC/banana 1m
  • Cable GPIB IEEE488/IEEE488, 2m
  • Cable RS-232 RS-232, 2m
  • WinQbase Database SW
  • CALIBER SW module for automatic calibration of multimeters.
 

More products MEATEST

10KV HIGH RESISTANCE DECADE FOR CALIBRATING MEGOHMMETERS AND INSULATION TESTERS MEATEST M191

• Total resistance range 10.00 k? to 1000.0 G?
• Resistance accuracy 0.1 to 5 %
• Test voltage range 10 000 VDC + 5%
• Test voltage accuracy indication 0.5 % + 10 V
• Test current indication 4 digit from 0.01 pA to 99.99 mADC
• Programmable high resistance decade box
• Short current verification
• Dielectric and absorption parameters simulation: polarization index (PI), dielectric absorption ratio (DAR) and polarization ratio (PR)
• High voltage capacitance in three fix points 10, 50, 100 nF
• HIPOT timer verification

 

HIGH PRECISION UNIVERSAL CALIBRATOR MEATEST M142I

• 15ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 30 A
• TC temperature sensors simulation
• RS232 interface

 

MEATEST M143 PRECISION MULTIFUNCTION CALIBRATOR

• Wide voltage range from 0 to 1000 V DC/AC with accuracy 0.01 %
• Extended current range from 0 to 20 A DC/AC with accuracy 0.02 %
• Extended current range to 1000 A for calibration of clamp ammeters
• Sinusoidal & Non-sinusoidal waveforms
• Fix standard resistors 10 O to 100 MO in decimal values with calibration accuracy 0.02 %
• Thermocouple temperature sensor simulation R, S, B, J, T, E, K, N in range from 250 °C to 1850 °C
• Cold junction automatic compensation using external Pt1000 sensor
• RTD temperature sensor simulator as option

 

POWER AND ENERGY CALIBRATOR MEATEST M133

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" in the 3phase system 2 V to 1200 V
• DC/AC current 8 mA to 30 A / 5 V
• Power factor setting -1 to +1
• Harmonic, interharmonic distortion, modulation
• Frequency range 15 Hz to 1 kHz
• Simulated electric power to 8.4 kVA (420 kVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

RTD SIMULATOR OF TEMPERATURE CONTROLLERS PT100, PT200, PT500, PT1000, NI100, NI1000 MEATEST M612

• Calibration of temperature controllers
• Resistance range from 16 O to 10 kO
• Simulation of Pt and Ni sensors
• Accuracy +/- 0.02°C
• Temperature stability < 1 ppm/°C
• Simulation of cable resistances
• Interface RS 232 (IEEE488 optionally)

 

POWER AND ENERGY CALIBRATOR MEATEST M133I

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" in the 3phase system 2 V to 1200 V
• DC/AC current 30 mA to 30 A / 5 V, accuracy 310 ppm
• Power factor setting -1 to +1
• Frequency range 15 Hz to 1 kHz
• Simulated electric power up to 8.4 kVA (420 kVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

PRECISION LABORATORY CALIBRATOR FOR VOLTAGE, CURRENT, RESISTANCE, CAPACITY, FREQUENCY MEATEST M140

• 35ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 20 A
• Resistance up to 50 MO, capacitance up to 50 µF
• TC/RTD temperature sensors simulation
• Frequency output up to 20 MHz
• Electric power up to 240 V / 10 A
• Built-in process multimeter
• GPIB & RS232 interface

 

CAPACITANCE DECADE FOR CALIBRATION LCR-METERS MEATEST M520

• Designed for RCL meters calibration
• Range of capacitance from 100 pF to 12 mF
• Basic accuracy 0.25 %
• Maximal operating voltage 50 V
• Power supplying from internal battery or power line adapter
• Remote control RS-232

 

RF RESISTANCE STANDARD FOR CALIBRATION OF LCR METERS MEATEST M530

• Resistance range 10 O to 1000 O
• Very low frequency dependency
• Applicable frequency range to 100 MHz
• Calibration of wide frequency range LCR meters

 

PRECISION RESISTANCE DECADE BOX MEATEST M622

• Resistance range 1.000 00 O - 1.200 000 MO
• Accuracy 0.005%
• Resolution from 10 µO
• Range of Pt sensor temperature simulation -200°C - +850°C
• Connection 2, 3, 4-wire
• Remote control RS232, optionally IEEE488
• Internal ACCU/power line adapter